Olink Explorer >5400

Closed Solicitation Posted

Solicitation number
75N98026Q00800
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Bethesda, Maryland 20892, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Health and Human Services National Institutes of Health Office of Logistics and Acquisition Operations seeks procurement of an Olink Explorer >5400 proteomics platform, with proposals due July 25, 2026. No set-aside applies.

Place of performance is Bethesda, Maryland. The requirement specifies the Olink Explorer >5400 platform to measure approximately 5,400 or more human proteins simultaneously in a single workflow using Proximity Extension Assay technology with dual antibody recognition coupled to DNA barcoding and next-generation sequencing readout. The platform must require only 2 microliters of plasma, serum, or other sample types as input; deliver reported 99.5% specificity with negligible cross-reactivity; and provide approximately 10 orders of magnitude dynamic range (fg/mL to mg/mL) to detect both low- and high-abundance proteins. The platform will support laboratory research on the role of inflammation, innate resistance, and commensal microbiota in carcinogenesis, cancer progression, and cancer therapy. Key capabilities include broad proteome coverage with antibody-based specificity, excellent sensitivity for low-abundance circulating proteins such as cytokines and signaling proteins, and standardization suitable for epidemiology and multi-omics studies. The NAICS code is 541380, Testing Laboratories and Services; the PSC code is Q301, Reference Laboratory Testing.

Notice text

Requirements:

2.0       BACKGROUND 

Our lab studies the role of inflammation/innate resistance and commensal microbiota in carcinogenesis, cancer progression and therapy of cancer. 

The following product features/characteristics are required for this requirement:  

Protein Coverage - Measures ~5,400+ human proteins simultaneously in a single workflow. 

Technology - Uses Proximity Extension Assay (PEA) with dual antibody recognition coupled to DNA barcoding and next-generation sequencing (NGS) readout. 

Sample input – requires only 2 ul of plasma, serum, and other sample types 

Specificity - Reported 99.5% specificity with negligible cross-reactivity due to dual-recognition antibody design. 

Dynamic Range - Approximately 10 orders of magnitude (fg/mL to mg/mL), enabling detection of both low- and high-abundance proteins. 

Key strengths 

  • Very broad proteome coverage while maintaining antibody-based specificity.  
  • Excellent sensitivity for low-abundance circulating proteins (especially cytokines and signaling proteins).  
  • Extremely low sample-volume requirement.  
  • Highly standardized platform, making it attractive for epidemiology and multi-omics studies.

Files

File Type Posted
Requirement 7.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
ChemiDoc Go Imaging System Hercules, California 94547, United States · NAICS 334516 Office of Logisitics and Acquisition Operations No set-aside
Benchtop biophysical instrument Oak Ridge, Tennessee 37830, United States · NAICS 334516 Department of Energy No set-aside
Notice of Intent to Sole Source – Werfen USA LLC – ACL TOP 750 Analyzers kits and reagents Bethesda, Maryland 20892, United States · NAICS 541380 Office of Logisitics and Acquisition Operations No set-aside
CSS - Beckman OptiMate Gradient Maker NAICS 334516 Office of Logisitics and Acquisition Operations No set-aside
Leica Microsystems, Inc. – Tokai Hit stage top incubator and Super Z Galvo stage Bethesda, Maryland, United States · NAICS 334516 Office of Logisitics and Acquisition Operations No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors