NRS Rhinelander, WI Replace 2 Electrical Panels 600 AMP and 100 AMP with surge protection

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
12445523Q0107
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Rhinelander, Wisconsin 54501, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The US Department of Agriculture (USDA) is seeking a contractor to replace outdated 600 AMP and 100 AMP circuit breaker panels and breakers in a 1960's wing, including the removal of old panels and installation of new ones with surge protection. The contractor will also be responsible for fixing any old, worn-out wiring that does not meet NFPA or electrical code standards. The work will be performed during normal working hours and will be inspected by the Facilities Operations Specialist before being signed off as completed.

Products and Services to be provided:

  1. Removal of old 600 AMP and 100 AMP circuit breaker panels and breakers.
  2. Installation of new 600 AMP main and 100 AMP sub panels.
  3. Installation of new breakers into the panel and labeling them according to the location they feed.
  4. Installation of a surge protection system to protect high-value lab equipment.
  5. Repair of any old, worn-out wiring that does not meet NFPA or electrical code standards.

Notice text

Replace outdated 600 AMP circuit breaker panel and breakers along with 100 AMP panel and breakers with surg protection.  The old panel will have to be removed before the new can be installed all wiring needs to be hard piped into boxes.


600 and 100 AMP for 1960’s Wing does not provide a positive lock out tag out on circuit breakers and are too old.   The breakers are not able to be replaced because company does not exist or make them anymore.  This is a major safety concern when replacing any equipment or lighting in 1960’s wing.

Files

File Type Posted
photo4.jpg JPG image
photo2.jpg JPG image
photo1.jpg JPG image
photo0.jpg JPG image
230714 SF 30 Amendment 0003.pdf PDF
photo3.jpg JPG image
230707 SF 30 Amendment 0002.pdf PDF
SF 30 (11_2016).pdf PDF
Questions and Answers for NRS Electrical Panels.docx DOCX document
J2 SOW Electrical Panel replacement.pdf PDF
Sol_12445523Q0107.pdf PDF
J1 DBA Wage Determination.pdf PDF
Show all 12

Notice history

Notice Type Posted
NRS Rhinelander, WI Replace 2 Electrical Panels 600 AMP and 100 AMP with surge protection Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Circuit breaker NAICS 335313 Land and Maritime No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors