NRS Rhinelander, WI Replace 2 Electrical Panels 600 AMP and 100 AMP with surge protection
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 12445523Q0107
- Agency
-
Forest Service
Department of Agriculture
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238990 All Other Specialty Trade Contractors
- Place of performance
- Rhinelander, Wisconsin 54501, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The US Department of Agriculture (USDA) is seeking a contractor to replace outdated 600 AMP and 100 AMP circuit breaker panels and breakers in a 1960's wing, including the removal of old panels and installation of new ones with surge protection. The contractor will also be responsible for fixing any old, worn-out wiring that does not meet NFPA or electrical code standards. The work will be performed during normal working hours and will be inspected by the Facilities Operations Specialist before being signed off as completed.
Products and Services to be provided:
- Removal of old 600 AMP and 100 AMP circuit breaker panels and breakers.
- Installation of new 600 AMP main and 100 AMP sub panels.
- Installation of new breakers into the panel and labeling them according to the location they feed.
- Installation of a surge protection system to protect high-value lab equipment.
- Repair of any old, worn-out wiring that does not meet NFPA or electrical code standards.
Notice text
Replace outdated 600 AMP circuit breaker panel and breakers along with 100 AMP panel and breakers with surg protection. The old panel will have to be removed before the new can be installed all wiring needs to be hard piped into boxes.
600 and 100 AMP for 1960’s Wing does not provide a positive lock out tag out on circuit breakers and are too old. The breakers are not able to be replaced because company does not exist or make them anymore. This is a major safety concern when replacing any equipment or lighting in 1960’s wing.
Files
| File | Type | Posted |
|---|---|---|
| photo3.jpg | JPG image | |
| photo4.jpg | JPG image | |
| photo2.jpg | JPG image | |
| photo1.jpg | JPG image | |
| photo0.jpg | JPG image | |
| 230714 SF 30 Amendment 0003.pdf | ||
| 230707 SF 30 Amendment 0002.pdf | ||
| SF 30 (11_2016).pdf | ||
| Questions and Answers for NRS Electrical Panels.docx | DOCX document | |
| J2 SOW Electrical Panel replacement.pdf | ||
| Sol_12445523Q0107.pdf | ||
| J1 DBA Wage Determination.pdf |
Show all 12
Notice history
| Notice | Type | Posted |
|---|---|---|
| NRS Rhinelander, WI Replace 2 Electrical Panels 600 AMP and 100 AMP with surge protection | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Circuit breaker | Land and Maritime | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity