NOTICE OF INTENT - Sole Source Johnson Controls Fire Detection and Alarm for the Chilled Water Plant Replacement and Utility Upgrades Project at the VA West Haven Campus
Closed Special Notice Posted
- Solicitation number
- W912WJ26X1B67
- Agency
-
ENDIST New England
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- Place of performance
- West Haven, Connecticut, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers Engineering District New England has published a Notice of Intent regarding a sole source procurement for Johnson Controls fire detection and alarm systems at the VA West Haven Campus. The notice, posted on February 4, 2026, indicates the agency's intention to award a contract on a non-competitive basis under FAR 6.103-1 authority. This special notice applies to the Chilled Water Plant Replacement and Utility Upgrades Project at the VA West Haven Campus and has a submission deadline of February 19, 2026. The procurement does not include any small business set-asides. Interested parties have until the stated deadline to submit relevant documentation or comments regarding this sole source determination.
The purpose of this procurement is to expand the existing campus-wide Simplex-Grinnell (now Johnson Controls) fire detection and alarm system to provide coverage for the new chilled water plant facility. The agency justifies the sole source approach based on the proprietary nature of the existing system and the requirement for seamless integration with the current network of sensors, pull stations, strobes, and speakers already installed across VA West Haven buildings. The new installation must support remote monitoring and management capabilities for safety personnel while meeting National Fire Protection Association (NFPA) and Joint Commission healthcare safety standards. Contractors interested in this opportunity must be capable of installing and integrating Johnson Controls fire alarm equipment compatible with the existing campus infrastructure. The notice indicates that equipment specifications will include fire alarm control panels, pull stations, and various wall or ceiling-mounted devices, though the complete statement of work details remain to be issued.
Notice text
Under the authority of FAR 6.103-1, the U.S. Army Corps of Engineers intends to require, on a sole source basis, a brand name requirement for the Johnson Controls systems in the Chilled Water Plant Replacement and Utility Upgrades Project at the VA West Haven Campus.
The existing fire detection and alarm system on the VA West Haven campus is a Simplex-Grinnell (now Johnson Controls) system. All buildings on the VA West Haven campus with a building fire detection and alarm system are network-connected and integrated into the campus-wide Simplex-Grinnell (now Johnson Controls) system. The campus-wide system allows VA West Haven police, facilities, and other safety personnel to remotely monitor, manage, access, and control fire alarm devices for each building on campus connected to the campus-wide system. The new fire alarm system for the chilled water plant will be connected to this existing system. This will allow VA West Haven personnel to monitor this new system extension along with the remainder of the existing campus.
The Simplex Grinnell (now Johnson Controls) fire detection and alarm system is a network of sensors, pull stations and other devices that provides the required infrastructure to provide patient & staff safety, as required by the National Fire Protection Association (NFPA) and the Joint Commission on healthcare safety. The system’s reliability is achieved by the proprietary nature of the network, which is common in the industry. For the system to work at an acceptable level of performance, fast, reliable communication among devices and annunciation of alarms must happen in seconds. When the new chilled water plant is constructed, the Simplex Grinnell system must be expanded to ensure proper coverage into the new space. This procurement will require the installation of the various equipment, including but not limited, to the following: fire alarm control panel(s), pull stations, wall- or ceiling-mounted strobes, wall- or ceiling-mounted speakers, wall- or ceiling-mounted combination speaker/strobes, monitor modules, control modules, duct smoke detectors with duct housing, sampling tube, and remote test stations, smoke detectors, heat detectors, etc. Device quantities may change as design develops. Part numbers are not included as they have yet to be determined and they may change based on delegated design submittals. As stated above, these devices are proprietary in nature and must be programmed and tested by a Simplex Grinnell employee.
If the Johnson Controls Fire Detection and Alarm devices are not sole sourced, then the fire detection and alarm systems for the new chilled water plant will not be connected to the campus-wide fire detection and alarm system, requiring the installation of a separate standalone system and a separate standalone monitoring station at all locations where this system is monitored. Communications interconnection will provide additional complication and require involvement from multiple system manufacturers to accomplish, if it is even possible. This will add additional complication to all future system modifications.
THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. It is a market research tool being used to determine the availability of other qualified sources that can meet the requirements identified above and inherent with the referenced Johnson Controls system. The Government is not obligated to and will not pay for any information received from potential sources as a result of this notice of intent. All responses received within 15 days of the posting of this notice of intent will be considered by the Government. A determination by the Government to require the brand name for the Johnson Controls system for the VA West Haven procurement based on this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purposes of determine whether to allow alternate system manufacturers.
Submit responses within 15 days of the posting of this notice of intent via email to: tyler.s.maryak@usace.army.mil and CC erin.e.bradley@usace.army.mil (list "W912WJ26X1B67 – JCI Fire Alarm" in the subject line of the email).
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA--Upgrade Fire Alarm System Construction 676-22-110 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity