This solicitation seeks the replacement of a generator at Surry Mountain Lake Dam in Surry, New Hampshire. The U.S. Army Corps of Engineers Engineering District New England requires a contractor to install a new generator and sub-base fuel tank outside near an existing service panel, provide a new underground feeder from the new generator to an existing generator terminal and double throw disconnect adjacent to an existing utility pole, provide a new service disconnecting means in a gatehouse where existing conductors enter the structure and extend power to a normal source of a new lockable double-throw disconnect, and provide a new lighting panel and associated transformer within the gatehouse to replace an existing panel. The evaluation criteria will consider technical qualifications, past performance, and price. The solicitation response deadline was extended to December 23, 2022.

This total small business set-aside has an estimated value between $250,000 to $500,000. The NAICS code is 238210 and PSC code is R499. Three bids were received by the deadline from Midwest Electrical Construction, RothCo, and Alpha Contractors Group ranging in price from $208,579.10 to $448,000.00. The work must be completed within one year at Surry Mountain Lake Dam in Surry, New Hampshire.

Notice text

4 versions

Update #4 · Latest ·

The generator replacement project will include, but not limited to, the following: a. Install a new generator and sub-base fuel tank outside near the existing service panel. b. Provide a new underground feeder from the new generator to the existing generator terminal and double throw disconnect adjacent to existing utility pole. c. Provide new service disconnecting means in the gatehouse where existing conductors enter the structure and extend power to normal source of new lockable double-throw disconnect. d. Provide new lighting panel and associated transformer within the gatehouse to replace existing. *Visit https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?solNo=W912WJ23B0002 to obtain more details.*

Update #3 ·

The generator replacement project will include, but not limited to, the following: a. Install a new generator and sub-base fuel tank outside near the existing service panel. b. Provide a new underground feeder from the new generator to the existing generator terminal and double throw disconnect adjacent to existing utility pole. c. Provide new service disconnecting means in the gatehouse where existing conductors enter the structure and extend power to normal source of new lockable double-throw disconnect. d. Provide new lighting panel and associated transformer within the gatehouse to replace existing.

Update #2 ·

The generator replacement project will include, but not limited to, the following: a. Install a new generator and sub-base fuel tank outside near the existing service panel. b. Provide a new underground feeder from the new generator to the existing generator terminal and double throw disconnect adjacent to existing utility pole. c. Provide new service disconnecting means in the gatehouse where existing conductors enter the structure and extend power to normal source of new lockable double-throw disconnect. d. Provide new lighting panel and associated transformer within the gatehouse to replace existing.

Update #1 ·

The generator replacement project will include, but not limited to, the following: a. Install a new generator and sub-base fuel tank outside near the existing service panel. b. Provide a new underground feeder from the new generator to the existing generator terminal and double throw disconnect adjacent to existing utility pole. c. Provide new service disconnecting means in the gatehouse where existing conductors enter the structure and extend power to normal source of new lockable double-throw disconnect. d. Provide new lighting panel and associated transformer within the gatehouse to replace existing. *Visit 'https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?solNo=W912WJ23B0002' to obtain more details.*

Files

File Type Posted
Bid Abstract.pdf PDF
Amendment 0003.pdf PDF
Amendment 0003_CON-SM-480_C-101-ANSI D.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Plans.pdf PDF
W912WJ23B0002.pdf PDF
Specs.pdf PDF

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
Surry Mountain Lake – New Generator Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT Mansfield Center, Connecticut, United States · NAICS 238290 ENDIST New England Total Small Business
Float Well Pipe Repairs, Surry Mountain Dam, Surry, NH Surry, New Hampshire, United States · NAICS 237990 ENDIST New England No set-aside
CRREL Generator Maintenance Services Hanover, New Hampshire, United States · NAICS 811310 Engineer Research and Development Center Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors