NCI Radiation Oncology Branch Acquisition of Elekta Unity Linac System for Radiation Therapy
Closed Special Notice Posted
- Solicitation number
- NIH-NOI-26-PCA-NCI-09516
- Agency
-
Office of Logisitics and Acquisition Operations
National Institutes of Health, Department of Health and Human Services
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 339112 Surgical and Medical Instrument Manufacturing
- Place of performance
- Bethesda, Maryland 20892, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The National Cancer Institute (NCI) of the National Institutes of Health issued a Notice of Intent to sole-source to Elekta, Inc., for acquisition of an integrated magnetic resonance-guided linear accelerator system, with a response deadline of July 30, 2026, at 11:00 AM Eastern Time. This is not a competitive solicitation; the statutory authority is 41 U.S.C. 3304(a)(1) and FAR 6.302-1, based on only one responsible source and no other supplies or services satisfying agency requirements. NCI's Center for Cancer Research, Radiation Oncology Branch, requires the system to support patient treatment and clinical research. Minimum specifications include a 7 Megavoltage photon beam, 160-leaf multileaf collimator, onboard 1.5 Tesla or greater magnetic resonance imaging system with imaging protocols for MR-guided external beam radiotherapy, Diffusion Weighted Imaging capability, motion imaging and treatment capability, low-attenuation MR receive coil, dedicated MRI console for imaging guidance and control, and patient positioning system. The contract will be firm-fixed-price and encompass acquisition, delivery, installation, commissioning, training, and warranty. NAICS 339112; PSC 6515.
Notice text
Notice of Intent to Sole Source
Notice ID: NIH-NOI-26-PCA-NCI-09516
Agency / Office: Department of Health and Human Services (HHS), National Institutes of Health (NIH), National Cancer Institute (NCI)
Notice Type: Special Notice
Posted Date: July 20, 2026
Response Date: July 30, 2026, 11:00 AM Eastern Time
NAICS Code: 339112 – Surgical and Medical Instrument Manufacturing
PSC: 6515 – Medical and Surgical Instruments, Equipment, and Supplies
Contracting Office Address:
National Institutes of Health
National Cancer Institute
Description
This is a combined synopsis / notice of intent to sole source and is not a request for competitive quotations or proposals.
The National Institutes of Health (NIH), National Cancer Institute (NCI), on behalf of the Center for Cancer Research (CCR), Radiation Oncology Branch (ROB), intends to negotiate and award a sole-source firm-fixed-price contract to Elekta, Inc., 400 Perimeter Center Terrace NE, Suite 50, Atlanta, GA 30346, for the acquisition, delivery, installation, commissioning, training, and warranty of an integrated magnetic resonance-guided linear accelerator system.
The statutory authority for this proposed sole-source action is 41 U.S.C. 3304(a)(1), as implemented by FAR 6.302-1, Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements.
Requirement
The Government requires a fully integrated MR-guided linear accelerator system to support patient treatment and clinical research. The minimum salient characteristics include:
- 7 Megavoltage (MV) photon beam
- 160-leaf multileaf collimator (MLC)
- Onboard 1.5 Tesla (or greater) magnetic resonance imaging system
- Imaging protocols explicitly created for MR-guided external beam radiotherapy
- Capability for Diffusion Weighted Imaging (DWI)
- Capability for imaging and treating in the presence of patient motion
- MR receive coil with low attenuation of the radiation beam
- Dedicated MRI console for imaging guidance and control
- Patient positioning system including flat table, comfort mattress, and indexable table
- Quality assurance capabilities and supporting software
- Site planning, delivery, installation, commissioning, training, and warranty
This equipment is mission-critical to patient treatment and clinical research because it enables high-resolution soft-tissue visualization and adaptive radiotherapy in a single integrated coordinate system, reducing geometric uncertainty associated with moving a patient between separate imaging and treatment systems.
Sole Source Basis
Based on market research, Elekta, Inc. is the only known responsible source capable of providing a commercially available, fully integrated 1.5 Tesla MR-guided linear accelerator system meeting the Government’s minimum needs.
The Government reviewed other systems in the broader radiation oncology market, including lower-field MR-guided systems, CBCT-based adaptive radiotherapy systems, and standalone MRI platforms. These alternatives do not satisfy the Government’s minimum requirement for a fully integrated 1.5T MR-Linac with the required imaging, treatment, adaptive planning, and OEM installation capabilities.
In addition, the proprietary nature of the system and the specialized site planning, shielding, installation, and commissioning requirements make Elekta the only responsible source for both the equipment and the associated implementation services.
Response Information
This notice is for informational purposes only. Any responsible source that believes it can meet the Government’s requirement may submit a capability statement for Government consideration.
Capability statements must clearly demonstrate the vendor’s ability to provide a commercially available, fully integrated 1.5 Tesla (or greater) MR-guided linear accelerator system meeting all minimum salient characteristics, including OEM-authorized delivery, installation, commissioning, training, and warranty support.
Responses must be submitted electronically no later than 11:00 AM Eastern Time on July 30, 2026.
Responses shall be limited to 10 pages and must include:
- Company name and address
- UEI number
- Point of contact name, email address, and telephone number
- Technical description of the proposed system
- Evidence that the proposed system meets all minimum salient characteristics
- Evidence of OEM authorization for sale, installation, and support
- Relevant past performance information for similar Federal or commercial installations
The Government will review all capability statements received by the closing date. A determination by the Government not to compete this proposed action based on responses to this notice is solely within the discretion of the Government.
Primary Point of Contact
Linda Smith
linda.smith2@nih.gov
Secondary Point of Contact
Danielle Tines
danielle.tines@nih.gov
Disclaimer
This notice does not constitute a solicitation, request for proposal, or request for quotation. The Government is not responsible for any costs incurred in responding to this notice.
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| NCI OA Special Notice of Subcontract Opportunity at the Frederick National Laboratory for Cancer Research” | National Cancer Institute | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity