Multiple Fence Repairs - Moody AFB - Amendment (0002)
Closed Solicitation Posted
- Solicitation number
- FA483025R0010
- Agency
-
Air Combat Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 561730 Landscaping Services
- Place of performance
- Moody AFB, Georgia, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Air Combat Command is procuring fence repair and replacement services at Moody Air Force Base and Grassy Pond in Georgia to address damage caused by Hurricane Helene. The current solicitation, following two amendments that significantly reduced the scope, now requires the replacement of three fence sections: a 535 linear foot chain link outfield fence at the Softball Field, a complete 10-foot chain link fence replacement at the Tennis Courts including privacy screening, and a 215-foot L-section chain link fence at the Maintenance Yard in Grassy Pond. All work must restore the fences to their pre-damage condition while ensuring safety, functionality, and aesthetics, with contractors required to provide all equipment, materials, waste disposal, and a minimum one-year warranty. The evaluation will be conducted using a lowest price technically acceptable approach, assessing both technical capability to meet the Statement of Work requirements and price. The proposal submission deadline is August 13, 2025, with questions having been due on August 5, 2025.
This opportunity is designated as a 100% Small Business Set-Aside with an estimated contract value between $25,000 and $100,000 under a firm-fixed-price arrangement. The solicitation does not identify any incumbent contractors, suggesting this may be a new procurement resulting from the hurricane damage. The work involves approximately 872 linear feet of chain link fencing across multiple locations, with specific technical requirements including 9-gauge galvanized steel, 2-inch diamond mesh, concrete footings minimum 3 feet deep, and bottom tension wire installation. Performance will occur at Moody Air Force Base in Georgia and the associated Grassy Pond facility in Lake Park, Georgia. Contractors must demonstrate past performance on similar projects and provide detailed action plans outlining their approach, timeline, and project management structure for completing all fence sections.
Notice text
3 versions
Update #3 · Latest ·
Amendment 0001 is to update the Statement of Work, and to extend the date offers are due to the date of 13 August 2025.
Amendment 0002 is to add the Questions and Answers to the solicitation.
This is a 100% Small Business Set-Aside. Moody AFB is looking for a company that can conduct the repair and replacement of damaged fences across multiple locations at Moody AFB and Grassy Pond, as detailed in the Statement of Work (SOW), which were damaged due to Hurricane Helene. The objective is to restore the fences to their pre-damage condition, ensuring safety, functionality, and aesthetics. The estimated magnitude of this construction project is between $25,000 and $100,000, in accordance with FAR 36.204(b).
Statement of Work
Replace Damaged Fences – 23d FSS
1. Scope
The project involves the replacement of two (2) fences located across Moody AFB and one (1) fence at Grassy Pond (Lake Park, GA). The damage was incurred during Hurricane Helene, necessitating the replacement of all or portions of three (3) total fences. The objective of the project is to restore the structural integrity, functionality, safety, and aesthetics of the fences at Moody AFB and Grassy Pond.
2. Background
23d FSS strives to meet the needs of our customer base. The outfield fence at the Softball Field (Moody AFB) has a 6’ chain link fence that needs to be replaced; the Tennis Courts (Moody AFB) has a 10’ chain link fence that needs to be replaced; and, the Maintenance Yard (Grassy Pond) has a long L-section of 6’ chain link fence that needs to be replaced. Neither Moody AFB nor Grassy Pond can fully supply the demand for our activities to our customers due to the fence damage sustained by Hurricane Helene. This has a direct, negative impact on the health of the MWRF. Replacing these three (3) fences will allow Moody AFB/Grassy Pond to recover these lines of income in support of the MWRF.
3. Requirements
3.1 Softball Field Chain Link Fence Repair (Moody AFB)
o Overall Dimensions of Section Needing to be Repaired
Height: 6’
Length: 535 LF (entire outfield fence)
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
10’ sections between posts
Posts buried 3’ in the ground
Reattach protective barrier on top of fence
Install bottom tension wire to eliminate ability to push bottom of the fence in and gain access to the area.
Stretch and secure material using tension bars and/or bands at terminal posts
o Site Preparation and Demolition
Remove and dispose of existing chain link fence and associated hardware into contractor provided dumpster(s).
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 3’ deep and properly cured before installation.
Level and plumb the fence section
3.2 Tennis Courts Chain Link Fence Repair (Moody AFB)
o Overall Dimensions of Entire Fence Needing to be Replaced
Height: 10’
Length: 122 LF x 112 LF x 122LF
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
Ensure proper spacing: 10’ on center
Secure connections with appropriate fittings
Install bottom tension wire to eliminate the ability to push the bottom of the fence in and gain access to the area.
New privacy screen to cover the entire fence.
• Privacy screens need to be secured with hog rings or comparable hardware
• Color of privacy screen to be chosen post-award
o Site Preparation and Demolition
Remove and dispose of existing chain link fence and associated hardware into contractor provided dumpster.
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 3’ deep and properly cured before installation.
Level and plumb the fence sections
3.3 Maintenance Yard Chain Link Fence (Grassy Pond)
o Overall Dimensions of Section Needing to be Repaired
Height: 6’
Length: 215’ L-Section
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
Ensure proper spacing: 10’ on center
Secure connections with appropriate fittings
Install bottom tension wire to eliminate ability to push bottom of the fence in and gain access to the area.
o Site Preparation and Demolition
Remove and dispose of damaged chain link fence and associated hardware into contractor provided dumpster.
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 2’-3’ deep and properly cured before installation.
Level and plumb the fence sections
Standard 1-year warranty to be provided by Contractor.
3.4 Equipment Requirements
All Equipment Required to Complete the Fences in Their Entirety Shall Be Supplied by the Contractor
Evaluation Criteria
In accordance with FAR 52.212-2, evaluation of offers will be based on the following factors:
-
Technical Capability: The contractor’s ability to meet the requirements as described in the Statement of Work (SOW).
-
Price: The lowest price technically acceptable.
-
Action Plan Requirement: Offerors are required to include a detailed action plan with their proposal. The action plan must clearly outline how the contractor will complete the work, the steps involved, and the timeline for each phase of the project.
Additional Information
-
This is a Firm-Fixed-Price contract.
-
All work must comply with applicable safety regulations.
-
The contractor is required to provide all necessary equipment, including PPE for the project, and dumpsters for proper disposal of material.
-
The contractor will also need to provide a portable restroom if necessary for the site.
Questions due 05 August 2025 @1000.
Point of Contact
For questions or concerns please contact:
Name: Darien Savage
Phone: (229) 257-2827
Update #2 ·
Amendment 0001 is to update the Statement of Work, and to extend the date offers are due to the date of 13 August 2025.
This is a 100% Small Business Set-Aside. Moody AFB is looking for a company that can conduct the repair and replacement of damaged fences across multiple locations at Moody AFB and Grassy Pond, as detailed in the Statement of Work (SOW), which were damaged due to Hurricane Helene. The objective is to restore the fences to their pre-damage condition, ensuring safety, functionality, and aesthetics. The estimated magnitude of this construction project is between $25,000 and $100,000, in accordance with FAR 36.204(b).
Statement of Work
Replace Damaged Fences – 23d FSS
1. Scope
The project involves the replacement of two (2) fences located across Moody AFB and one (1) fence at Grassy Pond (Lake Park, GA). The damage was incurred during Hurricane Helene, necessitating the replacement of all or portions of three (3) total fences. The objective of the project is to restore the structural integrity, functionality, safety, and aesthetics of the fences at Moody AFB and Grassy Pond.
2. Background
23d FSS strives to meet the needs of our customer base. The outfield fence at the Softball Field (Moody AFB) has a 6’ chain link fence that needs to be replaced; the Tennis Courts (Moody AFB) has a 10’ chain link fence that needs to be replaced; and, the Maintenance Yard (Grassy Pond) has a long L-section of 6’ chain link fence that needs to be replaced. Neither Moody AFB nor Grassy Pond can fully supply the demand for our activities to our customers due to the fence damage sustained by Hurricane Helene. This has a direct, negative impact on the health of the MWRF. Replacing these three (3) fences will allow Moody AFB/Grassy Pond to recover these lines of income in support of the MWRF.
3. Requirements
3.1 Softball Field Chain Link Fence Repair (Moody AFB)
o Overall Dimensions of Section Needing to be Repaired
Height: 6’
Length: 535 LF (entire outfield fence)
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
10’ sections between posts
Posts buried 3’ in the ground
Reattach protective barrier on top of fence
Install bottom tension wire to eliminate ability to push bottom of the fence in and gain access to the area.
Stretch and secure material using tension bars and/or bands at terminal posts
o Site Preparation and Demolition
Remove and dispose of existing chain link fence and associated hardware into contractor provided dumpster(s).
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 3’ deep and properly cured before installation.
Level and plumb the fence section
3.2 Tennis Courts Chain Link Fence Repair (Moody AFB)
o Overall Dimensions of Entire Fence Needing to be Replaced
Height: 10’
Length: 122 LF x 112 LF x 122LF
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
Ensure proper spacing: 10’ on center
Secure connections with appropriate fittings
Install bottom tension wire to eliminate the ability to push the bottom of the fence in and gain access to the area.
New privacy screen to cover the entire fence.
• Privacy screens need to be secured with hog rings or comparable hardware
• Color of privacy screen to be chosen post-award
o Site Preparation and Demolition
Remove and dispose of existing chain link fence and associated hardware into contractor provided dumpster.
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 3’ deep and properly cured before installation.
Level and plumb the fence sections
3.3 Maintenance Yard Chain Link Fence (Grassy Pond)
o Overall Dimensions of Section Needing to be Repaired
Height: 6’
Length: 215’ L-Section
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
Ensure proper spacing: 10’ on center
Secure connections with appropriate fittings
Install bottom tension wire to eliminate ability to push bottom of the fence in and gain access to the area.
o Site Preparation and Demolition
Remove and dispose of damaged chain link fence and associated hardware into contractor provided dumpster.
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 2’-3’ deep and properly cured before installation.
Level and plumb the fence sections
Standard 1-year warranty to be provided by Contractor.
3.4 Equipment Requirements
All Equipment Required to Complete the Fences in Their Entirety Shall Be Supplied by the Contractor
Evaluation Criteria
In accordance with FAR 52.212-2, evaluation of offers will be based on the following factors:
-
Technical Capability: The contractor’s ability to meet the requirements as described in the Statement of Work (SOW).
-
Price: The lowest price technically acceptable.
-
Action Plan Requirement: Offerors are required to include a detailed action plan with their proposal. The action plan must clearly outline how the contractor will complete the work, the steps involved, and the timeline for each phase of the project.
Additional Information
-
This is a Firm-Fixed-Price contract.
-
All work must comply with applicable safety regulations.
-
The contractor is required to provide all necessary equipment, including PPE for the project, and dumpsters for proper disposal of material.
-
The contractor will also need to provide a portable restroom if necessary for the site.
Questions due 05 August 2025 @1000.
Point of Contact
For questions or concerns please contact:
Name: Darien Savage
Phone: (229) 257-2827
Update #1 ·
This is a 100% Small Business Set-Aside. Moody AFB is looking for a company that can conduct the repair and replacement of damaged fences across multiple locations at Moody AFB and Grassy Pond, as detailed in the Statement of Work (SOW), which were damaged due to Hurricane Helene. The objective is to restore the fences to their pre-damage condition, ensuring safety, functionality, and aesthetics. The estimated magnitude of this construction project is between $25,000 and $100,000, in accordance with FAR 36.204(b).
Statement of Work
Replace Damaged Fences – 23d FSS
1. Scope
The project involves the replacement of five (5) fences located across Moody AFB and one
(1) fence at Grassy Pond (Lake Park, GA). The damages were incurred during Hurricane
Helene, necessitating the replacement of all or portions of six (6) total fences. The objective
of the project is to restore the structural integrity, functionality, safety, and aesthetics of the
fences at Moody AFB and Grassy Pond.
2. Background
23d FSS strives to meet the needs of our customer base. The Archery Range (Moody AFB)
has a 6-foot wood privacy fence that needs to be fully replaced; the RV Storage Lot (Moody
AFB) has an 8’ chain link fence that needs to be replaced; the Softball Field (Moody AFB)
has a section of chain link fence that needs to be replaced; the Tennis Courts (Moody AFB)
has a section of 10’ chain link that needs to be replaced; and, the Maintenance Yard (Grassy
Pond) has a long section of 6’ chain link fence that needs to be replaced. Neither Moody AFB
nor Grassy Pond can fully supply the demand for our activities to our customers due to the
fence damage sustained by Hurricane Helene. This has a direct, negative impact on the health
of the MWRF. Replacing these six (6) fences will allow Moody AFB/Grassy Pond to recover
these lines of income in support of the MWRF.
3. Requirements
3.1 Archery Range Wooden Fence Replacement (Moody AFB)
o Overall Dimensions
Height: 6’
Length: 98’
Post Spacing: 8’ on center
Post Depth: 12” below grade
o Material
Pressure treated wood
4x4 Posts set in concrete
One (1) bag of concrete per post, mixed and poured on site.
Galvanized or coated nails
No gates
o Site Preparation and Demolition
Remove and dispose of the current wooden privacy fence, and associated
materials, in a contractor provided dumpster.
Dig holes for the fence posts, mix concrete, pour concrete, and set the posts
in place. Ensure the posts are level, plumb, and securely anchored in the
concrete and the concrete is properly finished and cured.
Install the wood fence panels between the posts, ensuring they are level,
secure, and properly aligned.
Install the vertical pickets, spacing them evenly apart, and securing them to
the fence panels using appropriate nails.
3.2 RV Storage Lot Chain Link Fence (Moody AFB)
o Overall Dimensions
Height: 8’
Length: 202’ x 330’
Gates:
• 1 rolling/cantilever gate to replace the double gate up
front.
• 1 single gate with 24 ft. opening
Barbed wire: 3 strands around the entire fence
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
Line posts for 10’ sections
Install bottom tension wire to eliminate ability to push bottom of the fence
in and gain access to the area.
Stretch and secure material using tension bars and/or bands at terminal
posts
Gates and gate hardware
• Rolling/cantilever gate preferred
o Site Preparation and Demolition
Remove and dispose of existing damaged chain link fence and associated
hardware into contractor provided dumpster.
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 3’ deep and properly cured before
installation.
Level and plumb the fence section
3.3 Softball Field Chain Link Fence Repair (Moody AFB)
o Overall Dimensions of Section Needing to be Repaired
Height: 6’
Length: 10’
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
2 new line posts for 10’ section
Reattach protective barrier on top of fence
Install bottom tension wire to eliminate ability to push bottom of the fence
in and gain access to the area.
Stretch and secure material using tension bars and/or bands at terminal
posts
o Site Preparation and Demolition
Remove and dispose of existing 10’ section of chain link fence and
associated hardware into contractor provided dumpster.
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 3’ deep and properly cured before
installation.
Level and plumb the fence section
3.4 Tennis Courts Chain Link Fence Repair (Moody AFB)
o Overall Dimensions of Section Needing to be Repaired
Height: 10’
Length: 120’
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
Ensure proper spacing: 10’ on center
Secure connections with appropriate fittings
Install bottom tension wire to eliminate ability to push bottom of the fence
in and gain access to the area.
Privacy Screen to cover the section of fence being replaced.
o Site Preparation and Demolition
Remove and dispose of existing damaged chain link fence and associated
hardware into contractor provided dumpster.
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 3’ deep and properly cured before
installation.
Level and plumb the fence sections
3.5 Lodging Chain Link Fence Repair (Moody AFB)
o Overall Dimensions of Section Needing to be Repaired
Height: 5’
Length: 90’
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
Ensure proper spacing: 10’ on center
Secure connections with appropriate fittings
Install double-gates (12’ opening for double gate)
o Site Preparation and Demolition
Remove and dispose of damaged chain link fence and associated hardware
into contractor provided dumpster.
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 3’ deep and properly cured before
installation.
Level and plumb the fence sections
3.6 Maintenance Yard Chain Link Fence (Grassy Pond)
o Overall Dimensions of Section Needing to be Repaired
Height: 6’
Length: 215’ L-Section
o Material
Galvanized steel to match the existing fence
Mesh Size: 2” diamond mesh
Gauge: 9-gauge
Ensure proper spacing: 10’ on center
Secure connections with appropriate fittings
Install bottom tension wire to eliminate ability to push bottom of the fence
in and gain access to the area.
o Site Preparation and Demolition
Remove and dispose of damaged chain link fence and associated hardware
into contractor provided dumpster.
Prep the site for the line posts utilizing concrete footings for stability
Concrete footings to be minimum 2’-3’ deep and properly cured before
installation.
Level and plumb the fence sections
Standard 1-year warranty to be provided by Contractor.
3.7 Equipment Requirements
All Equipment Required to Complete the Fences in Their Entirety Shall Be
Supplied by the Contractor
Contractors are responsible for providing their own means and mode of
transportation to safely transport all the grills to the appropriate locations.
Submission Requirements
Offerors must submit the following with their proposal:
-
A detailed technical capability narrative showing their ability to perform the work.
-
A proposed timeline for completing the work.
-
A detailed action plan for the work to be accomplished.
-
Proof of past performance on similar projects.
-
A cost proposal, broken down by each fence section.
-
A warranty statement for all work performed, which must be a minimum of 1 year.
Evaluation Criteria
In accordance with FAR 52.212-2, evaluation of offers will be based on the following factors:
-
Technical Capability: The contractor’s ability to meet the requirements as described in the Statement of Work (SOW).
-
Price: The lowest price technically acceptable.
Additional Information
-
This is a Firm-Fixed-Price contract.
-
All work must comply with applicable safety regulations.
-
The contractor is required to provide all necessary equipment, including PPE for the project, and dumpsters for proper disposal of material.
-
The contractor will also need to provide a portable restroom if necessary for the site.
Action Plan Requirement
Offerors are required to include a detailed action plan with their proposal. The action plan must clearly outline how the contractor will complete the work, the steps involved, and the timeline for each phase of the project.
Site Visit will be conducted on 08May2025 @1000, the site visit will begin at 23 CONS, building 932. Questions due 09May2025 @1000.
Point of Contact
For additional information or to confirm attendance at the site visit, please contact:
Name: Robert McKettrick
Phone: (229) 257-3465
Files
| File | Type | Posted |
|---|---|---|
| Questions and Answers.pdf | ||
| SOW Fences.pdf | ||
| GA20250316 WD.pdf | ||
| SOW - Fence Repair.pdf | ||
| Base Pass Template.pdf | ||
| base map.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Human Performance Optimization Support Services | Air Combat Command | Total Small Business | |
| 10-Miler Fencing | Air Force Space Command | Total Small Business | |
| Airfield Blast Shield | Global Strike Command | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity