LMA JFF Replacement HVAC System

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
W912EF25RSS21
Agency
ENDIST Walla Walla US Army Corps of Engineers, Department of Defense
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
PSC
N041 Installation Of Equipment- Refrigeration, Air Conditioning, And Air Circulating Equipment
Place of performance
Kahlotus, Washington 99335, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Corps of Engineers (USACE), Walla Walla District, is conducting a sources sought notice for the replacement of HVAC systems at the Juvenile Fish Facility at Lower Monumental Lock & Dam. The project involves purchasing, installing, and commissioning two new electric HVAC systems for the first and second floors, which will include outdoor heat pump units, indoor ceiling-mounted air handler units, new thermostats, and associated components. Interested contractors are required to submit a capabilities package with details such as company information, CAGE code, UEI, business classification, and at least one project statement demonstrating competency in HVAC system supply. The market research aims to determine the availability of qualified firms, including small businesses, small-disadvantaged businesses, HUBZone businesses, woman-owned small businesses, and service-disabled veteran-owned small businesses. Responses must be submitted to Chandra Crow via email by 10:00 am Pacific Daylight Time on May 2, 2025.

The procurement is not set aside for any specific business category, with the small business size standard set at 1,250 employees for NAICS code 333415. The first-floor HVAC system will be a 4-ton electric split-type heat pump system with specific electrical requirements, cooling performance of 47,000 BTU/hr, and the second-floor system will be a 3-ton system with slightly different specifications. Both systems require R454B refrigerant, specific dimensional constraints, and include features like high-capacity dryers, crankcase heaters, and expansion valves. The government will evaluate responses based on technical capability, experience, and the ability to meet the detailed system requirements outlined in the sources sought notice. While no specific award value is mentioned, the procurement is for a direct replacement of existing HVAC systems with new, modern equipment designed to meet the facility's heating and cooling needs.

Notice text

2 versions

Update #2 · Latest ·

W912EF - THIS IS A SOURCES SOUGHT NOTICE AND SHOULD NOT BE CONSTRUED AS A SOLICITATION ANNOUNCEMENT. THE SUBMISSION OF THIS INFORMATION IS FOR PLANNING PURPOSES ONLY. IT IS NOT TO BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT TO PROCURE ANY SUPPLIES OR TO AWARD A CONTRACT ON THE BASIS OF THIS REQUEST FOR INFORMATION.

The US Army Corps of Engineers (USACE), Walla Walla District is seeking sources for a supply project: LMA JFF Replacement HVAC System. This project involves the purchase, installation, and commissioning of two new electric HVAC systems along with removal and disposal of the existing HVAC systems for the first floor and second floor of the Juvenile Fish Facility at Lower Monumental Lock & Dam. The determination of the acquisition strategy for this procurement lies solely with the Government and will be based on market research and information available to the Government from other sources. A market survey is being conducted to determine if there are a reasonable number of firms, large or small businesses, including small-disadvantaged businesses, HUBZONE small businesses, woman-owned small businesses, or service-disabled veteran-owned small businesses interested in and technically capable of performing the scope-of-work in the specified location. If you are capable and interested in this work, please respond accordingly.

Responses to this sources sought announcement will be used by the Government to make appropriate acquisition decisions. The NAICS Code for this acquisition is 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing. The small Business size standard for this NAICS is 1,250 employees. NO SOLICITATION IS CURRENTLY AVAILABLE.

BACKGROUND AND PURPOSE:

For the purposes of market research, the U.S Army Corps of Engineers, Walla Walla District requests letters of interest from qualified supply/manufacturing contractors capable of supplying the two new HVAC systems for the following project:

Lower Monumental Dam, Kahlotus, WA.

PROJECT DESCRIPTION:

Provide two new HVAC systems which shall be electric split-type systems and shall include outdoor heat pump units, indoor ceiling-mounted air handler units with auxiliary electric heat, new thermostats, and all auxiliary piping, refrigerant, wiring, adapters, and other components needed to make the new systems function properly as a direct replacement of the existing systems. The new systems shall be brand new and shall be the latest version of its kind offered by the manufacturer. All new equipment supplied such as outdoor heat pump units, air handler units, electric heating coils, and thermostats shall be manufactured by the same company as much as possible. The new systems shall conform to the following salient characteristics. Consideration will be given to alternate designs, that meet design intent with variations to specifications, with justification for any variations.  Any considerations and allowable specification variations shall be at the discretion of the Government.

3.1 FIRST FLOOR HVAC SYSTEM REQUIREMENTS

  1. Type: Electric split-type heat pump system
  2. Electric:
    1. Condenser: 208V, 3-phase, 60Hz, 30A Breaker
    2. Air Handler: 208V, 3-phase, 60Hz, 50A Breaker
  3. SEER: 14
  4. Size: 4 ton
  5. Refrigerant: R454B Freon
  6. Cooling Performance:
    1. 47,000 BTU/hr total capacity
    2. 33,500 BTU/hr sensible capacity
    3. Entering DB/WB temp: 80F/67F @ 95F ambient air temp
  7. Heat Pump Performance:
    1. High: 46,000 BTU/hr;
    2. Low: 29,000 BTU/hr @ design
    3. Heat Rise: 19.9F @ design
  8. Electric Auxiliary Heat Coil: 11.3 kW
  9. Ventilation:
    1. Main supply fan: 1 HP, ECM Multi-speed Constant Torque
    2. 1300 – 1500 CFM
    3. 0.5 – 0.6 in WC air resistance
    4. Orientation: Horizontal
    5. Heavy gauge galvanized steel cabinet
  10. Dimensions:
    1. Condenser:
      1. Match as closely as possible to existing unit.
      2. Not to exceed 35 in x 35 in x 40 in
    2. Air Handler:
      1. Match as closely as possible to existing unit
      2. Not to exceed 55 in x 22 in x 22 in
  11. Other Accessories/Features:
    1. High capacity drier factory-installed in liquid line
    2. Crankcase heater
    3. Check and expansion valve factory installed

3.2 SECOND FLOOR HVAC SYSTEM REQUIREMENTS

  1. Type: Electric split-type heat pump system
  2. Electric:
    1. Condenser: 208V, 3-phase, 60Hz, 20A Breaker
    2. Air Handler: 230V, 1-phase, 60Hz, 60A Breaker
  3. SEER: 15
  4. Size: 3 ton
  5. Refrigerant: R454B Freon
  6. Cooling Performance:
    1. 34,000 BTU/hr total capacity
    2. 25,800 BTU/hr sensible capacity
    3. Entering DB/WB temp: 80F/67F @ 95F ambient air temp
  7. Heat Pump Performance:
    1. High: 30,800 BTU/hr;
    2. Low: 19,600 BTU/hr @ design
    3. Heat Rise: 17.3F @ design
  8. Electric Auxiliary Heat Coil: 10 kW
  9. Ventilation:
    1. Main supply fan: 0.50 HP, ECM Variable Speed Constant Volume
    2. 1000 – 1200 CFM
    3. 0.5 – 0.6 in WC air resistance
    4. Orientation: Horizontal
    5. Heavy gauge galvanized steel cabinet
  10. Dimensions:
    1. Condenser:
      1. Match as closely as possible to existing unit.
      2. Not to exceed 35 in x 35 in x 40 in
    2. Air Handler:
      1. Match as closely as possible to existing unit
      2. Not to exceed 55 in x 22 in x 22 in
  11. Other Accessories/Features:
    1. High capacity drier factory-installed in liquid line
    2. Crankcase heater
    3. Check and expansion valve factory installed
    4. Variable speed direct driver blower motor

Interested firms should submit a capabilities package, to include the following:

1.  Firm's name, address, point of contact, phone number, and email address.

2.  CAGE code and UEI.

3.  Firm's interest in participating in the solicitation, if issued. 

4.  Business classification: Small Business (SB), Small Disadvantaged Business (SDB),Woman Owned Small Business (WOSB), Service-Disabled Veteran Owned Small Business (SDVOSB), Historically Underutilized Business Zone Small Business (HUBZone), 8(a), or Other than Small Business (Large Business).

5.  Firm's joint venture information (if applicable).

6. Interested parties who believe they can meet the requirements are invited to submit, in writing, complete information describing their interest and capability to meet all requirements stated above. At least one (1) project/capability statement should be provided to demonstrate competency and experience in the required area of supply.  Narratives shall be no longer than ten pages. 

Submit the above information to Chandra Crow, Contract Specialist, via email to Chandra.d.crow@usace.army.mil. Your response to the notice must be received on or before 10:00 am, Pacific Daylight Time on Friday 08 May 2025.

Update #1 ·

W912EF - THIS IS A SOURCES SOUGHT NOTICE AND SHOULD NOT BE CONSTRUED AS A SOLICITATION ANNOUNCEMENT. THE SUBMISSION OF THIS INFORMATION IS FOR PLANNING PURPOSES ONLY. IT IS NOT TO BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT TO PROCURE ANY SUPPLIES OR TO AWARD A CONTRACT ON THE BASIS OF THIS REQUEST FOR INFORMATION.

The US Army Corps of Engineers (USACE), Walla Walla District is seeking sources for a supply project: MNA JFF Replacement HVAC System. This project involves the purchase, installation, and commissioning of two new electric HVAC systems along with removal and disposal of the existing HVAC systems for the first floor and second floor of the Juvenile Fish Facility at Lower Monumental Lock & Dam. The determination of the acquisition strategy for this procurement lies solely with the Government and will be based on market research and information available to the Government from other sources. A market survey is being conducted to determine if there are a reasonable number of firms, large or small businesses, including small-disadvantaged businesses, HUBZONE small businesses, woman-owned small businesses, or service-disabled veteran-owned small businesses interested in and technically capable of performing the scope-of-work in the specified location. If you are capable and interested in this work, please respond accordingly.

Responses to this sources sought announcement will be used by the Government to make appropriate acquisition decisions. The NAICS Code for this acquisition is 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing. The small Business size standard for this NAICS is 1,250 employees. NO SOLICITATION IS CURRENTLY AVAILABLE.

BACKGROUND AND PURPOSE:

For the purposes of market research, the U.S Army Corps of Engineers, Walla Walla District requests letters of interest from qualified supply/manufacturing contractors capable of supplying the Laser Alignment Tool for the following project:

McNary Lock and Dam, Umatilla, OR.

PROJECT DESCRIPTION:

Provide two new HVAC systems which shall be electric split-type systems and shall include outdoor heat pump units, indoor ceiling-mounted air handler units with auxiliary electric heat, new thermostats, and all auxiliary piping, refrigerant, wiring, adapters, and other components needed to make the new systems function properly as a direct replacement of the existing systems. The new systems shall be brand new and shall be the latest version of its kind offered by the manufacturer. All new equipment supplied such as outdoor heat pump units, air handler units, electric heating coils, and thermostats shall be manufactured by the same company as much as possible. The new systems shall conform to the following salient characteristics. Consideration will be given to alternate designs, that meet design intent with variations to specifications, with justification for any variations.  Any considerations and allowable specification variations shall be at the discretion of the Government.

3.1 FIRST FLOOR HVAC SYSTEM REQUIREMENTS

  1. Type: Electric split-type heat pump system
  2. Electric:
    1. Condenser: 208V, 3-phase, 60Hz, 30A Breaker
    2. Air Handler: 208V, 3-phase, 60Hz, 50A Breaker
  3. SEER: 14
  4. Size: 4 ton
  5. Refrigerant: R454B Freon
  6. Cooling Performance:
    1. 47,000 BTU/hr total capacity
    2. 33,500 BTU/hr sensible capacity
    3. Entering DB/WB temp: 80F/67F @ 95F ambient air temp
  7. Heat Pump Performance:
    1. High: 46,000 BTU/hr;
    2. Low: 29,000 BTU/hr @ design
    3. Heat Rise: 19.9F @ design
  8. Electric Auxiliary Heat Coil: 11.3 kW
  9. Ventilation:
    1. Main supply fan: 1 HP, ECM Multi-speed Constant Torque
    2. 1300 – 1500 CFM
    3. 0.5 – 0.6 in WC air resistance
    4. Orientation: Horizontal
    5. Heavy gauge galvanized steel cabinet
  10. Dimensions:
    1. Condenser:
      1. Match as closely as possible to existing unit.
      2. Not to exceed 35 in x 35 in x 40 in
    2. Air Handler:
      1. Match as closely as possible to existing unit
      2. Not to exceed 55 in x 22 in x 22 in
  11. Other Accessories/Features:
    1. High capacity drier factory-installed in liquid line
    2. Crankcase heater
    3. Check and expansion valve factory installed

3.2 SECOND FLOOR HVAC SYSTEM REQUIREMENTS

  1. Type: Electric split-type heat pump system
  2. Electric:
    1. Condenser: 208V, 3-phase, 60Hz, 20A Breaker
    2. Air Handler: 230V, 1-phase, 60Hz, 60A Breaker
  3. SEER: 15
  4. Size: 3 ton
  5. Refrigerant: R454B Freon
  6. Cooling Performance:
    1. 34,000 BTU/hr total capacity
    2. 25,800 BTU/hr sensible capacity
    3. Entering DB/WB temp: 80F/67F @ 95F ambient air temp
  7. Heat Pump Performance:
    1. High: 30,800 BTU/hr;
    2. Low: 19,600 BTU/hr @ design
    3. Heat Rise: 17.3F @ design
  8. Electric Auxiliary Heat Coil: 10 kW
  9. Ventilation:
    1. Main supply fan: 0.50 HP, ECM Variable Speed Constant Volume
    2. 1000 – 1200 CFM
    3. 0.5 – 0.6 in WC air resistance
    4. Orientation: Horizontal
    5. Heavy gauge galvanized steel cabinet
  10. Dimensions:
    1. Condenser:
      1. Match as closely as possible to existing unit.
      2. Not to exceed 35 in x 35 in x 40 in
    2. Air Handler:
      1. Match as closely as possible to existing unit
      2. Not to exceed 55 in x 22 in x 22 in
  11. Other Accessories/Features:
    1. High capacity drier factory-installed in liquid line
    2. Crankcase heater
    3. Check and expansion valve factory installed
    4. Variable speed direct driver blower motor

Interested firms should submit a capabilities package, to include the following:

1.  Firm's name, address, point of contact, phone number, and email address.

2.  CAGE code and UEI.

3.  Firm's interest in participating in the solicitation, if issued. 

4.  Business classification: Small Business (SB), Small Disadvantaged Business (SDB),Woman Owned Small Business (WOSB), Service-Disabled Veteran Owned Small Business (SDVOSB), Historically Underutilized Business Zone Small Business (HUBZone), 8(a), or Other than Small Business (Large Business).

5.  Firm's joint venture information (if applicable).

6. Interested parties who believe they can meet the requirements are invited to submit, in writing, complete information describing their interest and capability to meet all requirements stated above. At least one (1) project/capability statement should be provided to demonstrate competency and experience in the required area of supply.  Narratives shall be no longer than ten pages. 

Submit the above information to Chandra Crow, Contract Specialist, via email to Chandra.d.crow@usace.army.mil. Your response to the notice must be received on or before 10:00 am, Pacific Daylight Time on Friday 02 May 2025.

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
LMA JFF Replacement HVAC System Award Award Notice
LMA JFF Replacement HVAC System Latest solicitation Solicitation
LMA JFF Replacement HVAC System Pre-Solicitation
LMA JFF Replacement HVAC System This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity