Maintenance Renewal for Gatan Cameras

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
NIAID-SS-24-2203996
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Hamilton, Montana 59840, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The National Institute of Allergy and Infectious Diseases seeks to procure maintenance services for two Gatan 1067 GIF cameras installed on Krios electron microscopes. The services must include priority scheduling, onsite response within 48 hours, preventative maintenance inspections, software and hardware updates, and unlimited support calls and visits. Responses to the Sources Sought notice are due January 19th and must demonstrate the capability to meet the stated requirements.

There is no set-aside designation. The NAICS code is 541715 with PSC code J063. Responses are limited to six pages and must include priority scheduling timelines. The base period of performance is one year with four optional one-year extensions. Services will include one preventative maintenance inspection annually for each camera per 12-month period.

Notice text

Introduction
This is a Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement.


Project Summary
The National Institute of Allergy and Infectious Diseases (NIAID)’s Electron Microscopy Unit (EMU) of the Research Technologies Branch (RTB) provides state-of-the-art technologies to support the ultrastructural imaging needs of NIAID scientists both in the Bethesda, Maryland, area and at the Rocky Mountain Laboratories (RML) in Hamilton, Montana. The facility provides sample preparation and analysis ranging from basic to high resolution structural studies to immuno-localization of selected antigens for various specimens. Various methods, protocols, and equipment are employed to accommodate different preparative and imaging needs. Real-time viewing of samples by video image-sharing is available to NIAID users, allowing scientists at distant locations to view samples simultaneously with microscopy staff. To continue supporting the needs of NIAID researchers, the RTB must continue to upgrade and maintain its instrumentation.


The EMU supports NIAID investigators with various state-of-the-art microscopy techniques and technologies. The EMU requires service agreements for two Gatan 1067 GIF cameras (S/N 20102201W1067 and 19091107W1067) installed on Krios G1 and Krios G4 microscopes. These cameras are crucial for high-resolution data collection for structural studies involving drug and vaccine development. The high-resolution electron microscopes will be rendered unusable without functioning Gatan cameras. Original Equipment Manufacturer (OEM)-trained engineers and parts are essential in keeping the cameras working at peak performance. Without a service contract that includes preventive maintenance visits and prompt service to remedy a downed camera, the electron microscopy unit would fail to support the scientific mission of the NIAID investigators. 


Specifically, EMU is seeking maintenance service for various Gatan equipment listed below.

Gatan Equipment Info.              Serial No.                                  Description
1067 GIF BioContinuum           20102201W1067                       Krios G1
1067 GIF BioContinuum          19091107W1067                        Krios G4


The service of the Gatan cameras must meet the following minimum requirements:
1. Full coverage for OEM replacement parts, labor, and travel. Coverage includes all fees associated with repairs (labor and replacement parts for any service or repairs performed.
2. Priority scheduling and onsite response for all repairs during the period of performance. Priority is defined as giving priority scheduling equal to a direct contract and guaranteeing the equivalent manufacturer’s priority onsite response. If you are a third-party service provider, the priority scheduling and/or response time, must be listed in your response. OEM Trained Certified Technicians required.
3. One (1) Preventive Maintenance Inspections to be performed during a twelve-month period
4. 48-hour priority response time once service call received
5. Instrument control software and hardware proprietary updates (can occur during scheduled firmware updates upon request, and in conjunction with a scheduled Preventive Maintenance or Corrective Maintenance visit), including software revision. Provide End User License Agreement (EULA) if applicable.
6. Unlimited service visits during normal business days and hours, excluding Federal holidays.
7. Unlimited telephone support for instruments and applications and Remote Technical Support during business hours.


Anticipated Period of Performance
It is anticipated that an award will be made on or about March 1, 2024. The estimate base period of performance is from date of award through February 29, 2025. The period of performance shall be one (1) base year with four (4) one-year option periods.


Capability Statement/Information Sought
If your organization has the potential capacity to provide maintenance service which meets the minimum salient characteristics listed above, please provide the following information:
1. Organization name, address, point of contact, email address, website address, telephone number, UEI number


2. Type of business (e.g., 8(a), HUBZone, Other than Small, etc.) pursuant to the applicable NAICS code


3. Identification of any Best-in-Class contract vehicles including Government Wide Acquisition Contracts (GWAC) (e.g., GSA schedule, NITAAC) they may possess or are aware of that would support this possible requirement. If your organization does not provide the products/services under a GWAC, please identify availability as OPEN MARKET ONLY.

4. Tailored capability statement addressing the capability of the instrument to meet NIAID’s minimum salient characteristics. Capability document shall be no more than six pages. The priority scheduling and/or response time must be provided with your response.


Submission Instructions
Interested businesses who consider themselves qualified to provide the above listed maintenance service for this project are invited to submit a response to this Sources Sought Notice by January 19, at 3:00 PM EST. All responses under this Sources Sought Notice shall be emailed to Hershea Vance at hershea.vance@nih.gov.


Disclaimer and Important Notes
This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization’s qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.


Confidentiality
No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).

Notice history

Notice Type Posted
Maintenance Renewal for Gatan Cameras Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Service Maintenance for UM Blaze Microscope System Bethesda, Maryland 20892, United States · NAICS 811210 Office of Logisitics and Acquisition Operations No set-aside
1-Year OEM Service Contract - (2) Revvity Celigo S Imaging Instruments (VRC) Bethesda, Maryland 20892, United States · NAICS 811210 National Institute of Allergy and Infectious Diseases No set-aside
Maintenance Agreement: AxioScan. Z1 Microscopes Maryland 20892, United States · NAICS 811210 National Institute of Child Health and Human Development No set-aside
NOI - Maintenance and Service Agreement for Thermo NAICS 811210 Office of Logisitics and Acquisition Operations No set-aside
NCSS - Preventative Maintenance Service & Support NAICS 811210 Office of Logisitics and Acquisition Operations No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors