Liquid Chromatograph (LC) coupled with Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Closed Special Notice Posted

Solicitation number
98130
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Atlanta, Georgia 30341, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Centers for Disease Control and Prevention issued a sole-source justification notice for a firm fixed price purchase order to Agilent Technologies, Inc. for an integrated Liquid Chromatograph coupled with Inductively Coupled Plasma Mass Spectrometer system, with a response deadline of June 13, 2026.

The CDC's Respiratory Health Division/Field Studies Branch requires the Agilent 1260 Infinity III LC coupled with the Agilent 7900 ICP-MS to maintain compatibility with existing laboratory instrumentation and the Agilent MassHunter software platform currently in use. The system enables seamless integration with established analytical workflows—including instrument control, data acquisition, and data analysis—without requiring modification of existing methods or retraining of laboratory personnel. Market research identified one other vendor capable of providing an LC-ICP-MS system with similar analytical capabilities; however, that vendor's system does not integrate with the MassHunter software platform and would require revalidation of analytical methods, retraining, and operational downtime. The CDC determined that only the Agilent system meets the requirement for full system integration, continuity of operations, and efficient implementation within existing laboratory infrastructure.

Notice text

The Centers for Disease Control and Prevention intends to award a sole source firm fixed price purchase order to Agilent Technologies, Inc. for the Liquid Chromatograph (LC) coupled to Inductively Coupled Plasma (ICP) Mass Spectrometer (MS ).

The Agilent 1260 Infinity III liquid chromatograph (LC) coupled with the Agilent 7900 inductively coupled plasma–mass spectrometer (ICP-MS) provides a fully integrated LC-ICP-MS system that is compatible with the existing laboratory instrumentation and software platform (Agilent MassHunter) currently in use within the Respiratory Health Division/Field Studies Branch laboratories. This compatibility enables seamless integration with established analytical workflows, including instrument control, data acquisition, and data analysis, without requiring modification of existing methods or retraining of laboratory personnel. The Agilent system uniquely allows: (1) Direct integration with existing MassHunter software used across current laboratory instrumentation (2) Continuity of validated analytical methods and workflows  Minimization of training requirements and operational downtime (3) Consistent data processing and reporting across platforms (4) No other identified vendor provides an LC-ICP-MS system that integrates with the existing MassHunter software environment. As a result, only the Agilent system can meet the requirement for full system integration, continuity of operations, and efficient implementation within the existing laboratory infrastructure. Market research identified one vendor, as the only other vendor capable of providing an LC-ICP-MS system with similar analytical capabilities. However, the identified vendors system does not meet the Government’s requirements for compatibility with existing laboratory instrumentation and software. Specifically: (1) The system does not integrate with the Agilent MassHunter software platform currently used for instrument control and data analysis  (2)Implementation would require retraining of laboratory personnel on a new software system (3) Existing analytical methods and workflows would require modification, revalidation, or redevelopment (4) These changes would introduce delays in operational readiness and increase the risk of disruption to ongoing research activities (5) In addition to technical and operational limitations, the system was approximately $100,000 higher in cost than the Agilent system, without providing equivalent compatibility or operational efficiency. Selection of a non-compatible system would result in increased costs, extended implementation timelines, and potential impacts to data consistency and research continuity. Based on these factors, this vendor is not considered a reasonable alternative, and Agilent Technologies, Inc. is the only source capable of meeting all Government requirements.

This contract action is for supplies/service for which the Government intends to solicit and negotiate with only one source under the authority of Revolutionary FAR Overhaul 6.103-1 (SAP).

This notice of intent is not a request for competitive quotations; however, all quotations/responses received within 15 days of the issuance of this notice shall be considered by the government.  A determination by the government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the government.  Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement.  Any quotation/response should be emailed to contract specialist at email qsx8@cdc.gov by June 13, 2026 before 10am EST.

Similar open opportunities

Opportunity Agency Set-aside Responses due
Notice of Intent to Sole Source a Thermo Orbitrap Fusion Lumos and Thermo RSLCnano UPLC Maintenance Agreement Georgia 30329, United States · NAICS 811210 CDC Office of Acquisition Services No set-aside
Single Purchase of an Agilent 8890 GC System Custom with dual ECD detectors NAICS 221310 EPA Region 4 No set-aside
Notice of Intent to Sole Source – AB Sciex LLC Maryland 20892, United States · NAICS 339112 NIH Clinical Center No set-aside
Hidex 600SLe Liquid Scintillation Counter United States · NAICS 334516 National Institute on Drug Abuse No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity