Keystone and Webbers Dam Powerhouse - Excitation System Maintenance Service

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
W912BV26QA018
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Sand Springs, Oklahoma, United States
More information

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Corps of Engineers Engineering District Tulsa is seeking contractor services for Alstom Excitation System Maintenance Service at two hydroelectric power plants: Keystone Dam in Sand Springs, Oklahoma, and Webbers Falls Dam in Webbers Falls, Oklahoma. The contractor must perform inspection, diagnostics, and corrective maintenance on two excitation systems (U1 at Keystone and U2 at Webbers Falls), addressing known problems including failed TTM 221 modules, software dongle faults, and secondary controller errors. Key requirements include providing all necessary equipment, materials, and labor; complying with Army Corps of Engineers Safety and Health Requirements Manual (EM 385-1-1); delivering test reports following IEEE/ANSI standards; and furnishing an Accident Prevention Plan. Work must be completed within 180 days of contract award, with hours limited to Monday through Thursday between 6:00 AM and 4:30 PM. The due date for questions and responses to this pre-solicitation notice is November 28, 2025, and interested parties should direct inquiries to Contract Specialist Mrs. Tamara Seals at tamara.l.seals@usace.army.mil or (918) 669-4977.

This is an unclassified procurement with no set-aside designation, meaning it is open to all eligible contractors without restrictions for small businesses, women-owned businesses, or other protected categories. The government has not disclosed an estimated award value in the pre-solicitation notice. Payment will be made in a lump sum upon completion and acceptance of work, and the contractor must provide a full replacement warranty covering defects in workmanship for twelve months from the date of delivery and acceptance. The procurement focuses on two excitation systems at the specified dam locations, with the NAICS category classified as Motor and Generator Manufacturing (335312) and the PSC category as Motors, Electrical (6105). The Performance Work Statement specifies detailed technical requirements including laptop configurations and software versions for each site, demonstrating the specialized nature of the maintenance work required.

Notice text

Keystone Dam and Webbers Falls Dam Powerhouse - Alstom Excitation System Maintenance Service. Contractor shall supply equipment, materials and labor as require performing inspection, diagnostics, and corrective maintenance on a quantity of two excitation systems designated U1 at the Keystone Dam hydroelectric power plant and U2 at the Webbers Falls Dam hydroelectric power plant. The contractor shall correct known excitation system problems and report problems revealed through diagnostics with proposed corrective maintenance to the government. Questions concerning this Sources Sought should be e-mailed to the Contract Specialist, Mrs. Tamara Seals at tamara.l.seals@usace.army.mil; phone number (918) 669-4977.

Files

Notice history

Notice Type Posted
Keystone and Webbers Dam Powerhouse - Excitation System Maintenance Service Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Webbers Falls Excitation System Replacements NAICS 237990 ENDIST Tulsa No set-aside
Tenkiller Hydropower Excitation System Replacement Gore, Oklahoma, United States · NAICS 237990 ENDIST Tulsa No set-aside
Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT Mansfield Center, Connecticut, United States · NAICS 238290 ENDIST New England Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity