About this opportunity

The Army Materiel Command Army Contracting Command Aberdeen Proving Ground is soliciting market capability information on chemical hazard detection and identification systems through a Request for Information (RFI) with responses due by September 10, 2026. This RFI does not constitute a commitment to contract, and the Government will not reimburse respondents for submission costs.

JPM CBRN IEW requires systems capable of detecting and/or identifying vapor and/or aerosol chemical hazards for worldwide defense missions. Proposed solutions must achieve a Technology Readiness Level of 5 or higher and detect Chemical Warfare Agents, Non-Traditional Agents, and Pharmaceutical-Based Agents. Systems must operate on platform power for fixed installations and vehicles, or on internal/external battery power for dismounted and portable missions. Application domains include surveillance, reconnaissance (mounted and dismounted), masking and unmasking operations, protection of installations and facilities, protection of personnel within collective protection systems, and decontamination support.

Respondents must submit detection technology overviews, system capability and mission compatibility assessments, remote command and control functionality details, comprehensive testing results, Technology Readiness Level and Manufacturing Readiness Level estimations with effort required to reach TRL 9 and MRL 10, company information, and authorized points of contact. Submissions must be formatted on standard 8.5 by 11-inch pages with minimum 10-point font, with proprietary information clearly marked. Responses should be emailed to Michael Hughes (james.m.hughes88.civ@army.mil) and Frank Sanchez (frank.r.sanchez1.civ@army.mil) by the deadline. Direct questions to Stacey Jump, Contracting Officer.

Notice text

Request for Information (RFI)

RFI Announcement #W911SR-27-R-CHDI

Title: Joint Project Manager Chemical Biological Radiological Nuclear Integrated

Early Warning (JPM CBRN IEW)

Chemical Hazard Detection and Identification Systems

1.0 DISCLAIMER:

This announcement constitutes a Request for Information (RFI) for the purpose of determining market capability of sources or obtaining information. It does not constitute a Request for Proposal (RFP), a Request for Quote (RFQ) or an indication that the Government will contract for any of the items and/or services discussed in this notice. Information on the specific topics of interest is provided in the following sections of this announcement. Neither JPM CBRN IEW nor any other part of the federal government will be responsible for any cost incurred by responders in furnishing this information.

2.0 BACKGROUND

The Joint Project Manager for Chemical, Biological, Radiological, and Nuclear Integrated Early Warning (JPM CBRN IEW) requires a system or systems capable of detecting and/or identifying vapor and/or aerosol chemical hazards. JPM CBRN IEW will utilize the system(s) to conduct and support critical defense missions worldwide. These mission applications span several key CBRN missions, including but not limited to:

  • ATP 3-11.37: o Surveillance: Monitoring an area or point.

o Reconnaissance (Mounted and Dismounted): Including detection when handheld or on the move integrated into military platforms.

  • ATP 3-11.32:

      • Masking and Unmasking Operations: Supporting donning and removing masks.
      • Protection Of Installations, Facilities, and Infrastructure:
        • Monitoring area and communicating results.
        • Includes ship integrated capability(s) o Protection in Chemical Environments: Warfighter protection, postattack recovery, etc. o Protection Of Personnel: Monitoring of Collective Protection
  • ATP 3-11.33:
      • Decontamination Support: Monitoring decontamination area, locate contamination, emplaced on vapor control line, etc.
      • Contamination control for Airlift Operations: Monitor area while on site, cargo coming on platform, and monitor cargo area in flight.

3.0 PURPOSE

The purpose of this RFI is to conduct a comprehensive market survey to identify and analyze technologies capable of detecting and/or identifying vapor and/or aerosol chemical hazards. Proposed solution sets should have a Technology Readiness Level (TRL) of 5 or higher.

The Government is highly open to multiple solutions from single sources, orthogonal technologies, novel concepts, or strategic partnering between vendors. Proposed solution sets may address only a portion of the desired operational capabilities. JPM CBRN IEW will analyze all received information papers to assess capabilities and, at its sole discretion, may release follow-on notifications. 

4.0 TECHNICAL & SYSTEM REQUIREMENTS

Interested parties are invited to submit information on technologies that align with the following technical parameters:

  1. Hazard Detection Spectrum: Systems must be capable of detecting, classifying, and/or identifying vapors and/or aerosols of:

      1. Chemical Warfare Agents (CWAs)
      2. Non-Traditional Agents (NTAs)
      3. Pharmaceutical Based Agents (PBAs)
  2. Power Requirements (if necessary):
      1. Platform/Fixed Sites: Systems must be capable of operating directly from platform power when integrated into vehicles, vessels, or fixed sites.
      2. All Other Missions: Systems must be capable of operating on internal/external battery power to support dismounted, portable, and temporary site missions.
  3. Target Maturity Level: Proposed solution sets should have a TRL of 5 or higher.

5.0 SUBMISSION REQUIREMENTS

Submissions must adhere to the following formatting and content rules:

  • Detection Technology: Provide an overview of the proposed detection technology(s).
  • System Capability & Compatibility: Discuss the system(s) capability(s) and detail its compatibility with the missions identified in Section 2 and the requirements outlined in Section 4.
  • Remote Command and Control: If applicable, provide an overview of the implemented command and control function. Otherwise, provide an estimation of effort required to develop a remote command and control function.
  • Testing Summary: Provide a comprehensive summary of testing results.
  • TRL Estimation: Provide an estimation of the Technology Readiness Level (TRL) with supporting rationale, including a discussion on the required effort to reach a TRL of 9 if currently at a lower level.
  • MRL Estimation: Provide an estimation of the Manufacturing Readiness Level (MRL) with supporting rationale, including a discussion on the required effort to reach an MRL of 10 if currently at a lower level.
  • Company Information: Include official company name, address, telephone number, website, and business type (large/small business classification).
  • Point of Contact: Provide the name, title, telephone number, and email address of the authorized company representative.
  • Formatting: Standard 8.5 x 11-inch pages, with font size no smaller than 10-point.

6.0 SUBMISSION GUIDANCE

The Government will retain all comments and information received in response to this RFI. Respondents must clearly mark any proprietary information as "Company Proprietary." Do not apply Government security classification markings to any submission.

Submit all written responses via email no later than 10 September 2026 Email submissions must be sent to ALL of the following recipients:

  • Michael Hughes – james.m.hughes88.civ@army.mil
  • Frank Sanchez - frank.r.sanchez1.civ@army.mil

7.0 POINTS OF CONTACT

For questions regarding this RFI, please use the email listed below.

  • Stacey Jump – Contracting Officer

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Request for Information – Prophylactic Platform for Medical Countermeasures Frederick, Maryland 21702, United States · NAICS 541715 ACC Aberdeen Proving Ground No set-aside
Request for Information (RFI) for Joint Project Manager for Chemical, Biological, Radiological and Nuclear Protection (JPM CBRN P) Chemically Protected Deployable Medical System (CP DEPMEDS) Natick, Massachusetts 01760, United States · NAICS 541614 ACC Aberdeen Proving Ground No set-aside
Call to Industry: Commercial Software RFI ACC Aberdeen Proving Ground No set-aside
CPE CBRND Seeking Physical Vapor Deposition (PVD) of Silicon Dioxide (SiO2) on Aluminum Flakes for Screening Obscuration Module - Multispectral (SOM-M) Gunpowder, Maryland 21010, United States · NAICS 332812 ACC Aberdeen Proving Ground No set-aside
Handheld Spectrometer Corpus Christi, Texas 78419, United States · NAICS 334516 ACC Redstone No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors