J059--Uninterrupted Power Supply (UPS) Maintenance Support Services at the VHA-MS Topeka and VHA-MSCC Fort Riley KS
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25926Q0793
- Agency
-
Veterans Integrated Service Network 19
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811210 Electronic and Precision Equipment Repair and Maintenance
- Place of performance
- Department of Veterans Affairs Veterans Health Administration - Member Services Topeka, Kansas 66604, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 19 is conducting a sources sought notice for uninterruptible power supply (UPS) systems maintenance support services at VHA-Member Services locations in Topeka and Fort Riley, Kansas, with responses due August 27, 2026. This is a market research notice and request for information only; no award will be made on responses submitted, and the Government makes no commitment to issue a subsequent solicitation.
The requirement covers preventive maintenance and corrective repair services for seven UPS units and seven battery cabinets totaling 264 batteries across a base year (September 15, 2026 through September 14, 2027) plus four option years. The Topeka site contains four Liebert UPS units (50–100 kVA capacity); Fort Riley contains three Staco Energy UPS units (125–200 kVA capacity). Deliverables include semi-annual preventive maintenance on UPS units and battery cabinets, quarterly battery voltage and condition checks, corrective repairs as needed, and 24/7 emergency repair response with an eight-hour on-site response requirement for after-hours calls.
Contractor qualifications require a minimum of three years of verifiable experience on commercial UPS systems of 100 kVA or greater, with demonstrated technical capability and OEM training certification or manufacturer authorization specific to Liebert and Staco Energy platforms. Technician qualifications include valid electrical licensure, three years of hands-on UPS experience, current OSHA 10-Hour General Industry certification, and Lead Compliance/Exposure Control training. A qualified supervisor holding OSHA 30-Hour certification must be on-site during all work. All scheduled maintenance occurs during duty hours (6:00 AM–3:30 PM CST) with UPS systems in bypass mode, coordinated with the Contracting Officer Representative at least 48 hours in advance. Performance standards include 100 percent PM completion within required frequency windows, 95 percent response-time adherence, and defect-free corrective work with no repeat failures during the one-year warranty period.
Interested contractors must submit capabilities and qualifications statements, proposed solutions overview, and responses to a market research table questionnaire addressing the draft Statement of Work and Salient Characteristics List.
Notice text
Sources Sought Notice - Uninterrupted Power Supply (UPS) Systems Maintenance Support Services for the Veterans Health Administration (VHA) - Member Services' (MS') Topeka and Fort Riley Kansas Locations
Disclaimer:
This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Information Requested from Industry:
In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.
Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.
Description of Requirement:
The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for UPS System Maintenance Support Services for the VHA-MS Topeka and Fort Riley Kansas Locations. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.
Services:
Item No.
Item Description
1
VHA-MS Topeka, KS Uninterrupted Power Supply (UPS) and Battery Cabinet systems Preventive Maintenance (PM) Semi-annual services in accordance with (IAW) the Statement of Work (SOW).
2
VHA-MS Topeka, KS Battery Quarterly check services IAW the SOW.
3
VHA-MSCC Fort Riley, KS UPS systems PM Semi-annual services IAW the SOW.
4
VHA-MSCC Fort Riley, KS Battery Quarterly check services IAW the SOW.
3
Unscheduled Maintenance Repair Parts IAW the SOW.
4
Unscheduled Maintenance Repair Labor Services IAW the SOW.
In response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met:
Company Name:
Address:
SAM UEI (Unique Entity ID) Number:
Business Size Information - Select all that applies:
Small Business
Emerging Small Business
Small Disadvantaged Business
Certified under Section 8(a) of the Small Business Act
HUBZone
Woman Owned
Certified Service-Disabled Veteran Owned Small
Veteran Owned Small Business
Large Business
Federal Acquisition Regulation (FAR) Market Rearch Questions:
Limitations on Subcontracting RFO 52.219-14
What percentage of the work would be subcontracted to another company? ________
What is the business size of the subcontractor? ______
Per RFO 52.219-14 the following conditions must be met:
Services (except construction), it will not pay more than 50 percent of the amount paid by the Government for contract performance to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract;
If subcontracting, Complete the table below identifying, for each SOW work element, which entity (your firm or a named subcontractor) will actually perform it and the credential that qualifies that entity.
SOW Element
Performed By (Prime / Named Sub)
Qualifying Credential Held By That Entity
Liebert (Npower/EXM) UPS PM & repair Section 5.1, 7, 8
Staco Energy (FLE-series) UPS PM & repair Section 5.2, 7, 8
Battery cabinet PM & IEEE 1188 testing Section 7.5 7.6
Thermal-runaway monitoring/response Section 7.8, 9.4
24/7 emergency on-site response Section 9
OEM / Technical Capability. For each platform, state whether your firm (as prime, using your own W-2 personnel) holds the capability, and attach proof:
Liebert (Npower and EXM): manufacturer-authorized status, OEM training certificate, or equivalent third-party certification attach copy. Prime self-performs Subcontracted
Staco Energy (FLE-series): manufacturer-authorized status, OEM training certificate, or equivalent attach copy. Prime self-performs Subcontracted
Personnel Qualifications (SOW: Section 6.3 6.5).
Do the technicians who would perform this work hold a valid electrical license/registration for the jurisdiction of performance (City of Topeka for Topeka work), or documented equivalent OEM/accredited UPS training? Attach a representative license/registration or training certificate.
Responsiveness & Logistics (Onsite Technician / Support):
Emergency response: The SOW requires 8-hour on-site emergency response, 24/7, at Topeka and Fort Riley, KS (Section 9). If your firm is not local, describe specifically how you would meet this (technician home base, staging, travel time noting travel time is not reimbursable).
Response Instructions:
Responses shall not exceed 8 pages. A cover letter not required.
Submit your response via email to John.Cheng2@va.gov
Submit your response NLT 12:00 (MDT) on Thursday, August 27, 2026;
Mark your response as Proprietary Information if the information is considered business sensitive.
VA has identified the appropriate North American Industry Classification System (NAICS) Code as 811210 - Electronic and Precision Equipment Repair and Maintenance with a Small Business size of $34 Million. If your company disagrees with the NAICS, please identify and explain the NAICS code(s) your company believes would better represent the predominant work based on the attached Statement of Work (SOW).
(End of Sources Sought)
Files
| File | Type | Posted |
|---|---|---|
| 36C25926Q0793.docx | DOCX document | |
| Statement of Work.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Automatic Transfer Switch (ATS) Preventive Maintenance and Repair Services, and Isolation Power Panel Inspection | Veterans Integrated Service Network 15 | No set-aside | |
| J065--Imaging UPSs Service Contract | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| 6135--UPS Battery Replacement | Veterans Integrated Service Network 22 | Total Small Business | |
| J061--Eaton Powerware System Replacement | Veterans Integrated Service Network 1 | Service-Disabled Veteran-Owned Small Business | |
| Preventive/Corrective Maintenance for Government Owned Uninterrupted Power Source System | Naval Supply Systems Command | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity