Intravascular Lithotripsy System_Sources Sought Notice
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25526Q0388
- Agency
-
Veterans Integrated Service Network 15
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 339112 Surgical and Medical Instrument Manufacturing
- Place of performance
- Kansas City, Missouri 64128, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
Veterans Integrated Service Network 15 is conducting a sources sought for a Coronary Shockwave Intravascular Lithotripsy system to be procured by the Kansas City VA Medical Center Cardiology Department, with responses due May 12, 2026 at 11:00 AM Central Time. This is market research only and does not constitute a binding solicitation.
The system prepares severely calcified coronary lesions for stenting by cracking calcium. Place of performance is Kansas City VA Medical Center, 4801 East Linwood Boulevard, Kansas City, Missouri 64128, Room M3.338 Lab 1.
Required deliverables comprise six line items: one Shockwave Starter Kit, four Shockwave C2+ IVL Catheters in sizes 2.5mm, 3.0mm, 3.5mm, and 4.0mm, and one IVL Generator with connector cable kit. The generator must accept 90–240 VAC input, deliver 3000 volts peak output at 1Hz pulse frequency, measure 7.9" x 2.9" x 11.1", and be mountable on an IV pole. A five-year manufacturer's warranty is required.
Responses should address company information, small business status, staffing and equipment capabilities, authorized distributor status, existing federal contracts, product comparisons, delivery timelines, maintenance requirements, and country of manufacture. Submit via email to Cory Rosene at cory.rosene@va.gov. NAICS 339112, size standard 1,000 employees. No set-aside. Responses are not binding offers and do not guarantee inclusion on a prospective bidders list.
Notice text
The Kansas City VA Medical Center Cardiology Department is requesting equipment Brand Name or Equal to the Coronary Shockwave Intravascular Lithotripsy system. This technology is designed to prepare severely calcified coronary lesions for stenting by cracking calcium in a safe and predictable manner. See attached document for additional details.
Files
| File | Type | Posted |
|---|---|---|
| 36C25526Q0388_Sources Sought Notice.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 36C255-27-AP-0365 - CT Contrast Injector Maintenance Services | Veterans Integrated Service Network 15 | No set-aside | |
| 6515--medtronic infinity thoracic tray | Veterans Integrated Service Network 6 | No set-aside | |
| Medical Device and Stand | MICC Fort Drum | Total Small Business | |
| 6515--Affera Mapping System - Cinci | Veterans Integrated Service Network 10 | No set-aside | |
| 6505--FY27 Low Energy General Radiopharmaceuticals 36C25027Q0052 | Veterans Integrated Service Network 10 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity