The National Institutes of Health Clinical Center intends to sole source procurement of BD Mission disposable core biopsy instruments from Bard Peripheral Vascular Inc. under 41 U.S.C. 253(c)(1) and FAR 6.302-1, with capability statements due by 12:00 PM Eastern on November 8, 2026. This is a Notice of Intent, not a request for proposal, and the Government's decision not to compete rests solely within its discretion. No set-aside is used. The single-use, sterile instruments support Interventional Radiology image-guided core needle biopsy procedures and are compatible with the BD TruGuide Disposable Coaxial Biopsy Needle. Specifications include 14G-20G gauges, 6-25 cm lengths, Advanced Echogenic Technology, a Fire Ready Indicator, and a penetration depth indicator with 10mm and 20mm presets. Delivery is requested on an as-needed, recurring basis via standard vendor shipment. The notice names no place of performance, quantity, value, or incumbent. Responding parties submit capability statements by email to valerie.gregorio@nih.gov, referencing NOI-OLAO-CC-27-000988 in the subject line. The requirement is classified under NAICS 339112 and PSC 6515.
Notice text
This is a Notice of Intent, not a request for proposal. The National Institute of Health, Clinical Center (NIH-CC) intends to negotiate on an other than full and open competition basis with the following vendor: Bard Peripheral Vascular Inc.
Acquisition Description:
Procurement of BD Mission™ Disposable Core Biopsy Instrument (semi-automatic, single-use) for use in Interventional Radiology image-guided core needle biopsy procedures. Device is compatible with the BD TruGuide™ Disposable Coaxial Biopsy Needle and is available in 14G–20G gauges and 6–25 cm lengths to accommodate a range of lesion depths and target sites. Features include Advanced Echogenic Technology for enhanced ultrasound visibility, a Fire Ready Indicator, and a penetration depth indicator (10mm/20mm presets).
Core Function: Supplies required: BD Mission™ Disposable Core Biopsy Instrument(s), single-use, sterile, for IR core needle biopsy procedures. Delivery is requested on an as-needed/recurring basis via standard vendor shipment
The statutory authority for this sole source requirement is 41 U.S.C. 253(c) (1) as implemented by FAR 6.302-1 only one responsible source and no other supply of service will satisfy agency requirements. THIS IS NOT A REQUEST FOR PROPOSAL. All responsible sources that could provide the required may submit a capability statement that will be considered by email (subject line to reference NOI-OLAO-CC-27-000988) by 12:00 PM eastern standard time on 11/08/2026 to: valerie.gregorio@nih.gov.