Initial Efficacy Testing of Autoclaves

Closed Solicitation Posted

Solicitation number
5-B201-Q-00598-00
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Illinois 60439, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Energy Office of Science, through Argonne National Laboratory, is seeking a qualified vendor to perform Initial Efficacy Testing (IET) on autoclaves used for on-site treatment of infectious waste. The contractor must verify and document that each autoclave model effectively renders infectious waste non-infectious, ensuring safe disposal while establishing validated operating parameters for ongoing treatment operations. The testing must comply with 35 Illinois Administrative Code 1422.124 and involves using self-contained biological indicators with Geobacillus stearothermophilus spores across multiple challenge loads with varying moisture contents. Vendors must demonstrate experience in autoclave efficacy testing and familiarity with regulatory standards, providing comprehensive documentation including updated IET reports for each autoclave model tested. Prospective bidders must submit numbered questions via email to the Contracting Officer and ensure all required documentation specified in the ANL-70 Request for Quotation is included, as incomplete submissions may be excluded from consideration. The proposal submission deadline is July 11, 2025, at 12:00 PM CDT.

This solicitation does not utilize any set-aside designations and will involve testing eight specific autoclave models at Argonne National Laboratory's facility in Lemont, Illinois. The contractor will direct an Argonne employee in operating the autoclaves during the testing process, which includes three challenge loads with different material categories such as blood cultures, fibers, metals, sharps, plastics, pathological waste, glassware, and non-woven fibers. The testing protocol requires precise load preparation, biological indicator placement, moisture content calculations, and validation through spore growth testing to ensure comprehensive efficacy verification. Vendors must comply with comprehensive safety, health, and environmental requirements including mandatory insurance coverage with $2 million general liability limits and adherence to Department of Energy safety standards. The contractor will be responsible for removing any debris resulting from their work and must submit a Job Safety Analysis as part of the on-site operational requirements.

Notice text

Argonne National Laboratory is seeking a qualified vendor to perform Initial Efficacy Testing (IET) on each autoclave model used for the on-site treatment of infectious waste at Argonne National Laboratory. The objective of the IETs is to verify and document that each autoclave effectively renders infectious waste non-infectious, thereby ensuring its safe disposal. Additionally, the results of the IETs will be used to establish validated operating parameters for the ongoing treatment of infectious waste.

Autoclave model details and additional information are included in the attached SOW document.

Prospective Bidders are required to review all attachments and provide all
documentation specified within the instructions and listed in the ANL-70 Request for Quotation. Please number all questions and send them via email directly to the Contracting Officer. Review all attachments prior to submitting
questions.
Note that failure to submit any required documents may result in the proposal being excluded from further consideration if not addressed before the offer deadline.Completed responses must be submitted no later than
12:00 PM (Noon) CDT on July 11, 2025, to the Contracting Officer.

We look forward to receiving your submission.