Hydraulic Unit 3 Year Requirements Contract
In accordance with (IAW) FAR 16.503 Requirements Contracts. Tooele Army Depot (TEAD) seeks qualified Small Businesses to enter into a Firm Fixed Price, Three (3) year Requirements contract to supply the following:
DESCRIPTION: CUSTOM HYDRAULIC POWER UNIT, 40 HP, 20 GPM, 3000 PSI, ASSEMBLY TO INCLUDE:
-60 GAL JIC RESERVOIR W/BAFFLE, DUAL CLEAN OUT COVERS, LEVEL TEMP GAUGE AND FILLER BREATHER ASSEMBLY.
-20 GPM FIXED DISPLACEMENT GEAR PUMP.
-40 HP 1800 RPM TEFC "C" FACE ELECTRIC MOTOR, 480 VAC/60Hz PUMP/MOTOR BELL HOUSING AND DRIVE COUPLING ASSEMBLY.
-PUMP SUCTION STRAINER.
-PRESSURE RELIEF VALVE SET TO 2,300 PSI.
-LIQUID FILLED PRESSURE GAUGE, 0-5000 PSI RANGE.
-10 MICRON ABSOLUTE RATED IN TANK RETURN LINE FILTER ASSEMBLY W/VISUAL CLOGGING INDICATOR.
-3 KW 480 VAC IN TANK IMMERSION HEATER W/THERMOSTAT, WIRED.
-LOW LEVEL/HIGH TEMP SWITCH (WIRED TO CONTROL PANEL).
-MANUAL DIRECTIONAL CONTROL VALVE FOR CRUSHER CIRCUIT.
DIRECTIONAL CONTROL VALVE HYDRAULIC, 1 BLANK DOUBLE ACTING SPRING RETURN, 80 MAX FLOW, 320 OPERATING PRESSURE BAR, LEVER OPERATED TYPE L100/LEVER STYLE AL001, SPOOL: 4-WAY, 3 POSITION; A/B TO TANK IN NEUTRAL; E: OPEN BY PASS; SPOOL ACTION 19, SECTION BODY: PARALLEL SAE 10 STANDARD CIRCUIT, LEFT OUTLET COVER: T AND CARRY-OVER H.P.C.O. SAE 12, RIGHT INLET MANIFOLD: ADJUSTABLE DIRECT ACTING RELIEF VALVE TYPE 15; STANDARD WITH P AND RV FOR PARALLEL CIRCUIT SAE 12. BUCHER P/N HDS20/1, T04-RV15, K04-C19, P08. (SAME AS EXISTING UNITS)
-3 PORT FLOW CONTROL FOR CRUSHER CIRCUIT. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 12 SAE. BRAND P/N FC51-12SAE. (SAME AS EXISTING UNITS).
-3 PORT FLOW CONTROL FOR COOLER FAN AND CONVEYOR CIRCUITS. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 8 SAE. BRAND P/N FC51-8SAE. (SAME AS EXISTING UNITS).
-BALL VALVE CONVEYOR ON/OFF VALVE HYDAC P/N KHB-16-SAE-1114-11X. (SAME AS EXISTING UNITS).
-AIR/OIL HEAT EXCHANGER WITH HYDRAULIC FAN MOTOR. CONNECTED.
-THERMOSTATIC COOLER BYPASS VALVE.
-ELECTRICAL CONTROL PANEL WITH MOTOR CONTACTOR AND HEATER CONTACTOR 480 VAC 60HZ 3 PHASE (WIRED TO DEVICES), WITH MOTOR STARTER. (CUSTOMER TO PROVIDE FUSED DISCONNECT).
-PLUMBED TO A CENTRAL BULKHEAD FOR CUSTOMER DEVICE CONNECTIONS WITH QUICK DISCONNECT FITTINGS, #12 JIC AND #8 JIC. FULLY ASSEMBLED, TESTED AND PAINTED.
-UNIT FOOTPRINT, 44" HIGH X 32" WIDE X 60" LONG.
-HYDRAULIC SCHEMATIC: IAW Drawing Attachment 1: 1410 HYDPWR, Attachment 2 1410 Updated Drawings -Available upon request.
-Hydraulic Fluid: DTE-25
-MUST BE FULLY ASSEMBLED. TURNKEY.
Estimated Ordering Requirements:
FY20 - 1 each
FY21 - 3 each
FY22 - 3 each
Ordering quantities are estimated and are subject to customer requirements.
Total Small Business Set-Aside.
Please Include FOB Destination in Quote. Delivery Address:
1 Tooele Army Depot Road-Bldg 503
Tooele, UT 84074-5003
Send Quotes via Email to:
JAMES M. DRAK
DA Civilian
Contract Specialist
Tooele Contracting Office CCRI-AAT
Depot Support Branch
Munitions & Industrial Base Division
Army Contracting Command-Rock Island
1 Tooele Army Depot Road-Bldg 510
Tooele, UT 84074-5003
(435) 833-2607/DSN 790-2607
James.m.drak.civ@mail.mil
Update #1 ·
10 September 2020
Tooele Army Depot
Hydraulic Unit 3 Year Requirements Contract
In accordance with (IAW) FAR 16.503 Requirements Contracts. Tooele Army Depot (TEAD) seeks qualified Small Businesses to enter into a Firm Fixed Price, Three (3) year Requirements contract to supply the following:
DESCRIPTION: CUSTOM HYDRAULIC POWER UNIT, 40 HP, 20 GPM, 3000 PSI, ASSEMBLY TO INCLUDE:
-60 GAL JIC RESERVOIR W/BAFFLE, DUAL CLEAN OUT COVERS, LEVEL TEMP GAUGE AND FILLER BREATHER ASSEMBLY.
-20 GPM FIXED DISPLACEMENT GEAR PUMP.
-40 HP 1800 RPM TEFC "C" FACE ELECTRIC MOTOR, 480 VAC/60Hz PUMP/MOTOR BELL HOUSING AND DRIVE COUPLING ASSEMBLY.
-PUMP SUCTION STRAINER.
-PRESSURE RELIEF VALVE SET TO 2,300 PSI.
-LIQUID FILLED PRESSURE GAUGE, 0-5000 PSI RANGE.
-10 MICRON ABSOLUTE RATED IN TANK RETURN LINE FILTER ASSEMBLY W/VISUAL CLOGGING INDICATOR.
-3 KW 480 VAC IN TANK IMMERSION HEATER W/THERMOSTAT, WIRED.
-LOW LEVEL/HIGH TEMP SWITCH (WIRED TO CONTROL PANEL).
-MANUAL DIRECTIONAL CONTROL VALVE FOR CRUSHER CIRCUIT.
DIRECTIONAL CONTROL VALVE HYDRAULIC, 1 BLANK DOUBLE ACTING SPRING RETURN, 80 MAX FLOW, 320 OPERATING PRESSURE BAR, LEVER OPERATED TYPE L100/LEVER STYLE AL001, SPOOL: 4-WAY, 3 POSITION; A/B TO TANK IN NEUTRAL; E: OPEN BY PASS; SPOOL ACTION 19, SECTION BODY: PARALLEL SAE 10 STANDARD CIRCUIT, LEFT OUTLET COVER: T AND CARRY-OVER H.P.C.O. SAE 12, RIGHT INLET MANIFOLD: ADJUSTABLE DIRECT ACTING RELIEF VALVE TYPE 15; STANDARD WITH P AND RV FOR PARALLEL CIRCUIT SAE 12. BUCHER P/N HDS20/1, T04-RV15, K04-C19, P08. (SAME AS EXISTING UNITS)
-3 PORT FLOW CONTROL FOR CRUSHER CIRCUIT. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 12 SAE. BRAND P/N FC51-12SAE. (SAME AS EXISTING UNITS).
-3 PORT FLOW CONTROL FOR COOLER FAN AND CONVEYOR CIRCUITS. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 8 SAE. BRAND P/N FC51-8SAE. (SAME AS EXISTING UNITS).
-BALL VALVE CONVEYOR ON/OFF VALVE HYDAC P/N KHB-16-SAE-1114-11X. (SAME AS EXISTING UNITS).
-AIR/OIL HEAT EXCHANGER WITH HYDRAULIC FAN MOTOR. CONNECTED.
-THERMOSTATIC COOLER BYPASS VALVE.
-ELECTRICAL CONTROL PANEL WITH MOTOR CONTACTOR AND HEATER CONTACTOR 480 VAC 60HZ 3 PHASE (WIRED TO DEVICES), WITH MOTOR STARTER. (CUSTOMER TO PROVIDE FUSED DISCONNECT).
-PLUMBED TO A CENTRAL BULKHEAD FOR CUSTOMER DEVICE CONNECTIONS WITH QUICK DISCONNECT FITTINGS, #12 JIC AND #8 JIC. FULLY ASSEMBLED, TESTED AND PAINTED.
-UNIT FOOTPRINT, 44" HIGH X 32" WIDE X 60" LONG.
-HYDRAULIC SCHEMATIC: IAW Drawing Attachment 1: 1410 HYDPWR-Available upon request.
-MUST BE FULLY ASSEMBLED. TURNKEY.
Estimated Ordering Requirements:
FY20 - 1 each
FY21 - 3 each
FY22 - 3 each
Ordering quantities are estimated and are subject to customer requirements.
Total Small Business Set-Aside.
Please Include FOB Destination in Quote. Delivery Address:
1 Tooele Army Depot Road-Bldg 503
Tooele, UT 84074-5003
Send Quotes via Email to:
JAMES M. DRAK
DA Civilian
Contract Specialist
Tooele Contracting Office CCRI-AAT
Depot Support Branch
Munitions & Industrial Base Division
Army Contracting Command-Rock Island
1 Tooele Army Depot Road-Bldg 510
Tooele, UT 84074-5003
(435) 833-2607/DSN 790-2607
James.m.drak.civ@mail.mil
Attachments
| File | Type | Posted |
|---|---|---|
| B08 W90WL520Q0025 Q and A.docx | DOCX document | |
| B08 W90WL520Q0025 Q and A.docx | DOCX document | |
| Required Soliciation Clause Fill-In FAR 52.204-24.docx | DOCX document | |
| B08 W90WL520Q0025 Q and A.docx | DOCX document | |
| W90WL520Q0025.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Hydraulic Power Units Requirements Contract | Award Notice | |
| Hydraulic Power Units Requirements Contract | Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity