Hydraulic Power Units Requirements Contract

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
W90WL520Q0025
Agency
ACC Rock Island Army Contracting Command, Department of Defense
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
333996 Fluid Power Pump and Motor Manufacturing
PSC
4320 Power And Hand Pumps
Place of performance
Tooele UT 84074 USA

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

10 September 2020

Tooele Army Depot

Hydraulic Unit 3 Year Requirements Contract

In accordance with (IAW) FAR 16.503 Requirements Contracts. Tooele Army Depot (TEAD) seeks qualified Small Businesses to enter into a Firm Fixed Price, Three (3) year Requirements contract to supply the following:

DESCRIPTION: CUSTOM HYDRAULIC POWER UNIT, 40 HP, 20 GPM, 3000 PSI, ASSEMBLY TO INCLUDE:

-60 GAL JIC RESERVOIR W/BAFFLE, DUAL CLEAN OUT COVERS, LEVEL TEMP GAUGE AND FILLER BREATHER ASSEMBLY.

-20 GPM FIXED DISPLACEMENT GEAR PUMP.

-40 HP 1800 RPM TEFC "C" FACE ELECTRIC MOTOR, 480 VAC/60Hz PUMP/MOTOR BELL HOUSING AND DRIVE COUPLING ASSEMBLY.

-PUMP SUCTION STRAINER.

-PRESSURE RELIEF VALVE SET TO 2,300 PSI.

-LIQUID FILLED PRESSURE GAUGE, 0-5000 PSI RANGE.

-10 MICRON ABSOLUTE RATED IN TANK RETURN LINE FILTER ASSEMBLY W/VISUAL CLOGGING INDICATOR.

-3 KW 480 VAC IN TANK IMMERSION HEATER W/THERMOSTAT, WIRED.

-LOW LEVEL/HIGH TEMP SWITCH (WIRED TO CONTROL PANEL).

-MANUAL DIRECTIONAL CONTROL VALVE FOR CRUSHER CIRCUIT.

DIRECTIONAL CONTROL VALVE HYDRAULIC, 1 BLANK DOUBLE ACTING SPRING RETURN, 80 MAX FLOW, 320 OPERATING PRESSURE BAR, LEVER OPERATED TYPE L100/LEVER STYLE AL001, SPOOL: 4-WAY, 3 POSITION; A/B TO TANK IN NEUTRAL; E: OPEN BY PASS; SPOOL ACTION 19, SECTION BODY: PARALLEL SAE 10 STANDARD CIRCUIT, LEFT OUTLET COVER: T AND CARRY-OVER H.P.C.O. SAE 12, RIGHT INLET MANIFOLD: ADJUSTABLE DIRECT ACTING RELIEF VALVE TYPE 15; STANDARD WITH P AND RV FOR PARALLEL CIRCUIT SAE 12. BUCHER P/N HDS20/1, T04-RV15, K04-C19, P08. (SAME AS EXISTING UNITS)

-3 PORT FLOW CONTROL FOR CRUSHER CIRCUIT. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 12 SAE. BRAND P/N FC51-12SAE. (SAME AS EXISTING UNITS).

-3 PORT FLOW CONTROL FOR COOLER FAN AND CONVEYOR CIRCUITS. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 8 SAE. BRAND P/N FC51-8SAE. (SAME AS EXISTING UNITS).

-BALL VALVE CONVEYOR ON/OFF VALVE HYDAC P/N KHB-16-SAE-1114-11X. (SAME AS EXISTING UNITS).

-AIR/OIL HEAT EXCHANGER WITH HYDRAULIC FAN MOTOR. CONNECTED.

-THERMOSTATIC COOLER BYPASS VALVE.

-ELECTRICAL CONTROL PANEL WITH MOTOR CONTACTOR AND HEATER CONTACTOR 480 VAC 60HZ 3 PHASE (WIRED TO DEVICES), WITH MOTOR STARTER. (CUSTOMER TO PROVIDE FUSED DISCONNECT).

-PLUMBED TO A CENTRAL BULKHEAD FOR CUSTOMER DEVICE CONNECTIONS WITH QUICK DISCONNECT FITTINGS, #12 JIC AND #8 JIC. FULLY ASSEMBLED, TESTED AND PAINTED.

-UNIT FOOTPRINT, 44" HIGH X 32" WIDE X 60" LONG.

-HYDRAULIC SCHEMATIC: IAW Drawing Attachment 1: 1410 HYDPWR, Attachment 2 1410 Updated Drawings -Available upon request.

-Hydraulic Fluid: DTE-25

-MUST BE FULLY ASSEMBLED. TURNKEY.

Estimated Ordering Requirements:

FY20 - 1 each

FY21 - 3 each

FY22 - 3 each

Ordering quantities are estimated and are subject to customer requirements.

Total Small Business Set-Aside.

Please Include FOB Destination in Quote. Delivery Address:

1 Tooele Army Depot Road-Bldg 503

Tooele, UT 84074-5003

Send Quotes via Email to:

JAMES M. DRAK

DA Civilian

Contract Specialist

Tooele Contracting Office CCRI-AAT

Depot Support Branch

Munitions & Industrial Base Division

Army Contracting Command-Rock Island

1 Tooele Army Depot Road-Bldg 510

Tooele, UT 84074-5003

(435) 833-2607/DSN 790-2607

James.m.drak.civ@mail.mil

Update #1 ·

10 September 2020

Tooele Army Depot

Hydraulic Unit 3 Year Requirements Contract

In accordance with (IAW) FAR 16.503 Requirements Contracts. Tooele Army Depot (TEAD) seeks qualified Small Businesses to enter into a Firm Fixed Price, Three (3) year Requirements contract to supply the following:

DESCRIPTION: CUSTOM HYDRAULIC POWER UNIT, 40 HP, 20 GPM, 3000 PSI, ASSEMBLY TO INCLUDE:

-60 GAL JIC RESERVOIR W/BAFFLE, DUAL CLEAN OUT COVERS, LEVEL TEMP GAUGE AND FILLER BREATHER ASSEMBLY.

-20 GPM FIXED DISPLACEMENT GEAR PUMP.

-40 HP 1800 RPM TEFC "C" FACE ELECTRIC MOTOR, 480 VAC/60Hz PUMP/MOTOR BELL HOUSING AND DRIVE COUPLING ASSEMBLY.

-PUMP SUCTION STRAINER.

-PRESSURE RELIEF VALVE SET TO 2,300 PSI.

-LIQUID FILLED PRESSURE GAUGE, 0-5000 PSI RANGE.

-10 MICRON ABSOLUTE RATED IN TANK RETURN LINE FILTER ASSEMBLY W/VISUAL CLOGGING INDICATOR.

-3 KW 480 VAC IN TANK IMMERSION HEATER W/THERMOSTAT, WIRED.

-LOW LEVEL/HIGH TEMP SWITCH (WIRED TO CONTROL PANEL).

-MANUAL DIRECTIONAL CONTROL VALVE FOR CRUSHER CIRCUIT.

DIRECTIONAL CONTROL VALVE HYDRAULIC, 1 BLANK DOUBLE ACTING SPRING RETURN, 80 MAX FLOW, 320 OPERATING PRESSURE BAR, LEVER OPERATED TYPE L100/LEVER STYLE AL001, SPOOL: 4-WAY, 3 POSITION; A/B TO TANK IN NEUTRAL; E: OPEN BY PASS; SPOOL ACTION 19, SECTION BODY: PARALLEL SAE 10 STANDARD CIRCUIT, LEFT OUTLET COVER: T AND CARRY-OVER H.P.C.O. SAE 12, RIGHT INLET MANIFOLD: ADJUSTABLE DIRECT ACTING RELIEF VALVE TYPE 15; STANDARD WITH P AND RV FOR PARALLEL CIRCUIT SAE 12. BUCHER P/N HDS20/1, T04-RV15, K04-C19, P08. (SAME AS EXISTING UNITS)

-3 PORT FLOW CONTROL FOR CRUSHER CIRCUIT. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 12 SAE. BRAND P/N FC51-12SAE. (SAME AS EXISTING UNITS).

-3 PORT FLOW CONTROL FOR COOLER FAN AND CONVEYOR CIRCUITS. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 8 SAE. BRAND P/N FC51-8SAE. (SAME AS EXISTING UNITS).

-BALL VALVE CONVEYOR ON/OFF VALVE HYDAC P/N KHB-16-SAE-1114-11X. (SAME AS EXISTING UNITS).

-AIR/OIL HEAT EXCHANGER WITH HYDRAULIC FAN MOTOR. CONNECTED.

-THERMOSTATIC COOLER BYPASS VALVE.

-ELECTRICAL CONTROL PANEL WITH MOTOR CONTACTOR AND HEATER CONTACTOR 480 VAC 60HZ 3 PHASE (WIRED TO DEVICES), WITH MOTOR STARTER. (CUSTOMER TO PROVIDE FUSED DISCONNECT).

-PLUMBED TO A CENTRAL BULKHEAD FOR CUSTOMER DEVICE CONNECTIONS WITH QUICK DISCONNECT FITTINGS, #12 JIC AND #8 JIC. FULLY ASSEMBLED, TESTED AND PAINTED.

-UNIT FOOTPRINT, 44" HIGH X 32" WIDE X 60" LONG.

-HYDRAULIC SCHEMATIC: IAW Drawing Attachment 1: 1410 HYDPWR-Available upon request.

-MUST BE FULLY ASSEMBLED. TURNKEY.

Estimated Ordering Requirements:

FY20 - 1 each

FY21 - 3 each

FY22 - 3 each

Ordering quantities are estimated and are subject to customer requirements.

Total Small Business Set-Aside.

Please Include FOB Destination in Quote. Delivery Address:

1 Tooele Army Depot Road-Bldg 503

Tooele, UT 84074-5003

Send Quotes via Email to:

JAMES M. DRAK

DA Civilian

Contract Specialist

Tooele Contracting Office CCRI-AAT

Depot Support Branch

Munitions & Industrial Base Division

Army Contracting Command-Rock Island

1 Tooele Army Depot Road-Bldg 510

Tooele, UT 84074-5003

(435) 833-2607/DSN 790-2607

James.m.drak.civ@mail.mil

Attachments

Files attached to this notice, newest first
File Type Posted
B08 W90WL520Q0025 Q and A.docx DOCX document
B08 W90WL520Q0025 Q and A.docx DOCX document
Required Soliciation Clause Fill-In FAR 52.204-24.docx DOCX document
B08 W90WL520Q0025 Q and A.docx DOCX document
W90WL520Q0025.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted