In accordance with (IAW) FAR 16.503 Requirements Contracts. Tooele Army Depot (TEAD) seeks qualified Small Businesses to enter into a Firm Fixed Price, Three (3) year Requirements contract to supply the following:

DESCRIPTION: CUSTOM HYDRAULIC POWER UNIT, 40 HP, 20 GPM, 3000 PSI, ASSEMBLY TO INCLUDE:

-60 GAL JIC RESERVOIR W/BAFFLE, DUAL CLEAN OUT COVERS, LEVEL TEMP GAUGE AND FILLER BREATHER ASSEMBLY.

-20 GPM FIXED DISPLACEMENT GEAR PUMP.

-40 HP 1800 RPM TEFC "C" FACE ELECTRIC MOTOR, 480 VAC/60Hz PUMP/MOTOR BELL HOUSING AND DRIVE COUPLING ASSEMBLY.

-PUMP SUCTION STRAINER.

-PRESSURE RELIEF VALVE SET TO 2,300 PSI.

-LIQUID FILLED PRESSURE GAUGE, 0-5000 PSI RANGE.

-10 MICRON ABSOLUTE RATED IN TANK RETURN LINE FILTER ASSEMBLY W/VISUAL CLOGGING INDICATOR.

-3 KW 480 VAC IN TANK IMMERSION HEATER W/THERMOSTAT, WIRED.

-LOW LEVEL/HIGH TEMP SWITCH (WIRED TO CONTROL PANEL).

-MANUAL DIRECTIONAL CONTROL VALVE FOR CRUSHER CIRCUIT.

DIRECTIONAL CONTROL VALVE HYDRAULIC, 1 BLANK DOUBLE ACTING SPRING RETURN, 80 MAX FLOW, 320 OPERATING PRESSURE BAR, LEVER OPERATED TYPE L100/LEVER STYLE AL001, SPOOL: 4-WAY, 3 POSITION; A/B TO TANK IN NEUTRAL; E: OPEN BY PASS; SPOOL ACTION 19, SECTION BODY: PARALLEL SAE 10 STANDARD CIRCUIT, LEFT OUTLET COVER: T AND CARRY-OVER H.P.C.O. SAE 12, RIGHT INLET MANIFOLD: ADJUSTABLE DIRECT ACTING RELIEF VALVE TYPE 15; STANDARD WITH P AND RV FOR PARALLEL CIRCUIT SAE 12. BUCHER P/N HDS20/1, T04-RV15, K04-C19, P08. (SAME AS EXISTING UNITS)

-3 PORT FLOW CONTROL FOR CRUSHER CIRCUIT. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 12 SAE. BRAND P/N FC51-12SAE. (SAME AS EXISTING UNITS).

-3 PORT FLOW CONTROL FOR COOLER FAN AND CONVEYOR CIRCUITS. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 8 SAE. BRAND P/N FC51-8SAE. (SAME AS EXISTING UNITS).

-BALL VALVE CONVEYOR ON/OFF VALVE HYDAC P/N KHB-16-SAE-1114-11X. (SAME AS EXISTING UNITS).

-AIR/OIL HEAT EXCHANGER WITH HYDRAULIC FAN MOTOR. CONNECTED.

-THERMOSTATIC COOLER BYPASS VALVE.

-ELECTRICAL CONTROL PANEL WITH MOTOR CONTACTOR AND HEATER CONTACTOR 480 VAC 60HZ 3 PHASE (WIRED TO DEVICES), WITH MOTOR STARTER. (CUSTOMER TO PROVIDE FUSED DISCONNECT).

-PLUMBED TO A CENTRAL BULKHEAD FOR CUSTOMER DEVICE CONNECTIONS WITH QUICK DISCONNECT FITTINGS, #12 JIC AND #8 JIC. FULLY ASSEMBLED, TESTED AND PAINTED.

-UNIT FOOTPRINT, 44" HIGH X 32" WIDE X 60" LONG.

-HYDRAULIC SCHEMATIC: IAW Drawing Attachment 1: 1410 HYDPWR, Attachment 2 1410 Updated Drawings -Available upon request.

-Hydraulic Fluid: DTE-25

-MUST BE FULLY ASSEMBLED. TURNKEY.

Estimated Ordering Requirements:

FY20 - 1 each

FY21 - 3 each

FY22 - 3 each

Ordering quantities are estimated and are subject to customer requirements.

Total Small Business Set-Aside.

Please Include FOB Destination in Quote. Delivery Address:

1 Tooele Army Depot Road-Bldg 503

Tooele, UT 84074-5003

Send Quotes via Email to:

JAMES M. DRAK

DA Civilian

Contract Specialist

Tooele Contracting Office CCRI-AAT

Depot Support Branch

Munitions & Industrial Base Division

Army Contracting Command-Rock Island

1 Tooele Army Depot Road-Bldg 510

Tooele, UT 84074-5003

(435) 833-2607/DSN 790-2607

James.m.drak.civ@mail.mil

Update #1 ·

10 September 2020

Tooele Army Depot

Hydraulic Unit 3 Year Requirements Contract

In accordance with (IAW) FAR 16.503 Requirements Contracts. Tooele Army Depot (TEAD) seeks qualified Small Businesses to enter into a Firm Fixed Price, Three (3) year Requirements contract to supply the following:

DESCRIPTION: CUSTOM HYDRAULIC POWER UNIT, 40 HP, 20 GPM, 3000 PSI, ASSEMBLY TO INCLUDE:

-60 GAL JIC RESERVOIR W/BAFFLE, DUAL CLEAN OUT COVERS, LEVEL TEMP GAUGE AND FILLER BREATHER ASSEMBLY.

-20 GPM FIXED DISPLACEMENT GEAR PUMP.

-40 HP 1800 RPM TEFC "C" FACE ELECTRIC MOTOR, 480 VAC/60Hz PUMP/MOTOR BELL HOUSING AND DRIVE COUPLING ASSEMBLY.

-PUMP SUCTION STRAINER.

-PRESSURE RELIEF VALVE SET TO 2,300 PSI.

-LIQUID FILLED PRESSURE GAUGE, 0-5000 PSI RANGE.

-10 MICRON ABSOLUTE RATED IN TANK RETURN LINE FILTER ASSEMBLY W/VISUAL CLOGGING INDICATOR.

-3 KW 480 VAC IN TANK IMMERSION HEATER W/THERMOSTAT, WIRED.

-LOW LEVEL/HIGH TEMP SWITCH (WIRED TO CONTROL PANEL).

-MANUAL DIRECTIONAL CONTROL VALVE FOR CRUSHER CIRCUIT.

DIRECTIONAL CONTROL VALVE HYDRAULIC, 1 BLANK DOUBLE ACTING SPRING RETURN, 80 MAX FLOW, 320 OPERATING PRESSURE BAR, LEVER OPERATED TYPE L100/LEVER STYLE AL001, SPOOL: 4-WAY, 3 POSITION; A/B TO TANK IN NEUTRAL; E: OPEN BY PASS; SPOOL ACTION 19, SECTION BODY: PARALLEL SAE 10 STANDARD CIRCUIT, LEFT OUTLET COVER: T AND CARRY-OVER H.P.C.O. SAE 12, RIGHT INLET MANIFOLD: ADJUSTABLE DIRECT ACTING RELIEF VALVE TYPE 15; STANDARD WITH P AND RV FOR PARALLEL CIRCUIT SAE 12. BUCHER P/N HDS20/1, T04-RV15, K04-C19, P08. (SAME AS EXISTING UNITS)

-3 PORT FLOW CONTROL FOR CRUSHER CIRCUIT. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 12 SAE. BRAND P/N FC51-12SAE. (SAME AS EXISTING UNITS).

-3 PORT FLOW CONTROL FOR COOLER FAN AND CONVEYOR CIRCUITS. FLOW CONTROL, PRESSURE, STANDARD FLOW CONTROL, CAST IRON, HEAT TREATED FOR FREE REVERSE CHECK SEAT, 3000psi RATED, NO RELIEF, 3 PORT 8 SAE. BRAND P/N FC51-8SAE. (SAME AS EXISTING UNITS).

-BALL VALVE CONVEYOR ON/OFF VALVE HYDAC P/N KHB-16-SAE-1114-11X. (SAME AS EXISTING UNITS).

-AIR/OIL HEAT EXCHANGER WITH HYDRAULIC FAN MOTOR. CONNECTED.

-THERMOSTATIC COOLER BYPASS VALVE.

-ELECTRICAL CONTROL PANEL WITH MOTOR CONTACTOR AND HEATER CONTACTOR 480 VAC 60HZ 3 PHASE (WIRED TO DEVICES), WITH MOTOR STARTER. (CUSTOMER TO PROVIDE FUSED DISCONNECT).

-PLUMBED TO A CENTRAL BULKHEAD FOR CUSTOMER DEVICE CONNECTIONS WITH QUICK DISCONNECT FITTINGS, #12 JIC AND #8 JIC. FULLY ASSEMBLED, TESTED AND PAINTED.

-UNIT FOOTPRINT, 44" HIGH X 32" WIDE X 60" LONG.

-HYDRAULIC SCHEMATIC: IAW Drawing Attachment 1: 1410 HYDPWR-Available upon request.

-MUST BE FULLY ASSEMBLED. TURNKEY.

Estimated Ordering Requirements:

FY20 - 1 each

FY21 - 3 each

FY22 - 3 each

Ordering quantities are estimated and are subject to customer requirements.

Total Small Business Set-Aside.

Please Include FOB Destination in Quote. Delivery Address:

1 Tooele Army Depot Road-Bldg 503

Tooele, UT 84074-5003

Send Quotes via Email to:

JAMES M. DRAK

DA Civilian

Contract Specialist

Tooele Contracting Office CCRI-AAT

Depot Support Branch

Munitions & Industrial Base Division

Army Contracting Command-Rock Island

1 Tooele Army Depot Road-Bldg 510

Tooele, UT 84074-5003

(435) 833-2607/DSN 790-2607

James.m.drak.civ@mail.mil

Files

File Type Posted
B08 W90WL520Q0025 Q and A.docx DOCX document
B08 W90WL520Q0025 Q and A.docx DOCX document
Required Soliciation Clause Fill-In FAR 52.204-24.docx DOCX document
B08 W90WL520Q0025 Q and A.docx DOCX document
W90WL520Q0025.pdf PDF

Notice history

Notice Type Posted
Hydraulic Power Units Requirements Contract Award Award Notice
This notice Latest solicitation Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors