9/14/2020 Contractor Question:
Can you please tell me what type of fluid is to be used in these units?
Government Response:
Hydraulic oil used is DTE-25.
9/15/2020 Contractor Question:
Learning that the elevation at Tooele is 5,043 feet, we will need to use flooded suction which will impact the footprint.
Not running out of footprint space until we consider the heat removal of the cooler. Our standard is 40% of the input HP. In this case we would remove 16 HP and that results in a large cooler and challenges the footprint allowance.
In order to optimize the air cooler size, please reply with the duty cycle of the operation: continuous or "on" some percentage of the time. Also what is the highest ambient room temperature?
Government Response:
The unit will run continuous. These units will be fielded worldwide. Sea level to potentially elevations higher then Tooele. These units also could experience a wide range of temperatures. Most will be operating outdoors. Anywhere from Alaska to El Paso Texas or the Middle East. We recommend that they be placed in at least a covered area but it's not mandatory.