The Department of the Army Materiel Command Contracting Command at Picatinny Arsenal is seeking a contractor to upgrade the HVAC system at the Smithfield USARC in Smithfield, PA. The key requirements include removing the existing variable refrigerant flow (VRF) system and installing new mini-split ductless systems, HVAC controls, and associated hardware and accessories. The contractor will be responsible for performing load calculations, providing temporary heating/cooling, and ensuring the new system can be integrated into an HVAC controls system. The work must comply with various federal regulations and standards. The pre-solicitation is posted on July 3, 2024, and responses are due by July 19, 2024.

Paragraph 2:

This procurement is set aside for small businesses. The contract value is not specified, but the work is expected to take 160 calendar days to complete from the notice to proceed. No potential incumbents or current contractors are mentioned.

Notice text

The Contractor shall provide all plant, labor, equipment, tools, materials, supervision, and transportation to accomplish the following work which consist of but is not limited to the removal of variable refrigerant flow systems (VRF), the installation of mini split ductless systems and all required hardware and accessories, and the installation and programming of HVAC controls systems.
All quantities are estimated. Contractor shall field verify all dimensions and quantities prior to ordering material. Failure of the contractor to conduct a site visit and appreciate the complexity of the specifications herein shall not indemnify said contractor from contract obligations as stated. All work completed herein shall be in accordance with but not limited to:


• UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS) –
HTTPS://WWW.WBDG.ORG/FFC/DOD/UNIFIED-FACILITIES-GUIDE-SPECIFICATIONS-UFGS
• UFC – UNIFIED FACILITIES CRITERIA
• ARMY REGULATION 420-1
• RCRA – RESOURCE CONSERVATION AND RECOVERY ACT
• EM 385-1-1, SAFETY and HEALTH REQUIREMENTS MANUAL

Files

Notice history

Notice Type Posted
HVAC System Smithfield, PA Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
HVAC Replacement, Bldg. 2821 NAICS 238220 Air Combat Command Total Small Business
Replace HVAC Rooftop Units at Building 2275 March Air Reserve Base, California 92518, United States · NAICS 238220 Army National Guard No set-aside
648-22-104 Correct HVAC Deficiencies (P&V) Portland, Oregon 97239, United States · NAICS 238220 Veterans Integrated Service Network 20 Service-Disabled Veteran-Owned Small Business
Gwmp - arho bunker HVAC NAICS 238220 Intermountain Region Service-Disabled Veteran-Owned Small Business
TVHS AC VRF System Installation Nashville, Tennessee 37212, United States · NAICS 238220 Veterans Integrated Service Network 9 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity