H999--Air Testing and Balancing

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C25225Q0281
Agency
Veterans Integrated Service Network 12 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
H999 Other Qc/Test/Inspect- Miscellaneous
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration, specifically Veterans Integrated Service Network 12, is seeking Air Testing and Balancing services for the Tomah VA Medical Center and two additional VA clinics in Wisconsin. The solicitation (36C25225Q0281) requires a contractor to perform comprehensive Testing, Adjusting & Balancing (TAB) reporting and air quality testing for critical care areas, including Airborne Infection Isolation Rooms, Sterile Processing Service areas, and Dental Treatment Rooms. Contractors must be National Environmental Balancing Bureau (NEBB) or Associated Air Balance Council (AABC) certified and capable of providing detailed air testing reports that include room air changes and pressure differentials. Quotes are due by April 14, 2025, at 8:00 AM CDT, with a mandatory site visit scheduled for April 1, 2025, at 10:00 AM local time. The evaluation will likely focus on technical capability, certification, and compliance with VHA HVAC Design Guide specifications.

The contract is set aside for small businesses under NAICS code 238220, with a size standard of $19 million. The base contract period runs from May 1, 2025, through April 30, 2026, with four additional one-year option periods available at the government's discretion. The scope of work covers 76 distinct rooms across multiple buildings, including the Tomah VA Medical Center and Community-Based Outpatient Clinics in La Crosse and Wausau, Wisconsin. The testing will be conducted annually, with specific requirements for air changes per hour and pressure differentials in various medical spaces. Contractors must be prepared to return and retest up to five rooms per site visit, with a maximum of two additional site visits per year if initial tests fail. While no specific award value is mentioned, the comprehensive nature of the testing and multiple facility coverage suggests a significant contract opportunity for qualified small businesses in the HVAC testing and balancing sector.

Notice text

.

Attachments

Files attached to this notice, newest first
File Type Posted
P07 - WD 2015-4929 Rev 27 12.23.2024.pdf PDF
P01 - Attachment A-Room Listing.pdf PDF
36C25225Q0281.docx DOCX document

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
H999--Air Balancing and Testing Award Award Notice
H999--Air Testing and Balancing This notice · Latest solicitation Solicitation
H999--Air Testing and Balancing Original Pre-Solicitation