H961--Inspection & Testing of Electrical Power Distribution System
Closed Pre-Solicitation Posted
- Solicitation number
- 36C24824Q0353
- Agency
-
Veterans Integrated Service Network 8
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Orlando Vamc at Lake Nona Orlando Vamc at Lake Baldwin
Notice details come from SAM.gov. Updated .
About this opportunity
This notice seeks information from companies interested in providing inspection, testing, and calibration services for electrical power distribution systems at various Department of Veterans Affairs medical facilities in Orlando, Florida over a three year period. Interested parties are requested to provide details on organizational experience, technical qualifications including NETA certification status, experience maintaining similar electrical systems, and whether subcontracting is anticipated by December 29, 2023. Responses will be evaluated to determine if the requirement should be set aside, sole sourced, or procured through full and open competition.
The applicable NAICS code is 238210, Specialty Trade Contractors, with a $19 million small business size standard. Services include inspection, testing, calibration and documentation of electrical switchboards, switchgear, transformers, motor control centers and related equipment at four VA medical centers totaling over 1,000 pieces of equipment. Based on the responses received, the requirement may be set aside for small businesses or sole sourced to an incumbent.
Notice text
Sources Sought Notice
Page 4 of 4
The Department of Veterans Affairs, Network Contracting Office 8 (NCO 8) is issuing this synopsis as a means of conducting market research to identify parties having an interest in and the capability to provide Inspection, Testing and Calibration of Electrical Power Distribution Systems at various Orlando VA Healthcare System (OVAHCS) facilities.
The Contractor shall provide all management, supervision, personnel, services, materials, supplies, facilities, transportation, and general and specialized equipment necessary to perform inspection, testing (Infrared Thermographic & Arc Flash included), calibration, and documentation of the Electrical Power Distribution Systems. Equipment includes:
Equipment Count by Type
Lake Nona
Lake Baldwin
Viera
Lakemont
AUTOMATIC TRANSFER SWITCH
61
8
4
3
ELECTRICAL SWITCHGEAR
186
4
2
2
TRANSFORMER
232
20
28
3
ELECTRICAL PANEL
899
167
82
26
Motor Control Centers (MCC)
15
7
-
1
ENCLOSED CIRCUIT BREAKER
221
-
-
-
Contractors shall have technical training and evident track records of working experience in Maintenance and Testing of electrical power distribution systems and related components in healthcare, industrial, educational, or commercial facilities for a minimum of five (5) years. Electrical components on which Contractors have experience shall include, but not be limited to, switchboards & switchgear (low and medium voltage), low voltage controls, oil filled disconnects, medium voltage distribution sub-stations, dry & oil filled transformers (medium voltage), switchgear circuit breakers (medium voltage), motor control centers, infrared thermographic inspections, arch flash testing, battery & battery charger inspections, ventilation inspections, external & internal enclosure inspections, calibration & functional checks, dielectric tests of oil, and other electrical appurtenances.
Contractors shall be certified by the InterNational Electrical Testing Association (NETA) or equivalent certifying organization as certified technicians, with each having completed the Occupational Safety & Health Administration (OSHA) approved 10-hour Construction Outreach Training or General Industry Outreach Training.
The results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 238210 with a small business size standard is $19,000,000.00.
Responses will be considered only from those who are regularly established in the business called for and, in the judgment of the Contracting Officer are financially responsible and able to show evidence of their reliability, ability, experience, equipment, facilities, and personnel directly employed or supervised by them to render prompt and satisfactory service. The Government is NOT seeking project management services.
If your organization has the potential capacity to perform these contract services, please provide the following information:
Organization name, address, telephone number, point of contact & email.
SAM UEI # number.
Federal Supply Schedule #, if applicable.
Socioeconomic status for NAICS: 238210 (SDVOSB, VOSB, WOSB, SB, Other, etc..).
Web site address (if applicable).
Narrative that addresses the organization s qualification and ability to perform services as a prime contractor.
List any accreditations your company holds.
Do you employ Level 3 or 4 NETA Certified Technicians?
If subcontracting or teaming is anticipated to deliver technical capability, organizations shall address the administrative and management structure of such arrangements in their response.
The government will evaluate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated.
BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES, SOLE SOURCED, OR PROCURED THROUGH FULL AND OPEN COMPETITION. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.
Submission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 11:00 AM (EST) on December 29, 2023. All responses under this Sources Sought Notice must be emailed using subject line Electrical Power Distribution Systems to Kurt.Kramer@va.gov.
Files
| File | Type | Posted |
|---|---|---|
| 36C24824Q0353.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J061--SOURCES SOUGHT NOTICE - Triennial Electrical Inspection Testing and Maintenance Services Requirement - Louis A Johnson VA Medical Center 36C24527Q0039 | Veterans Integrated Service Network 5 | No set-aside | |
| 36-Month Electrical Distribution Testing | Veterans Integrated Service Network 7 | Service-Disabled Veteran-Owned Small Business | |
| J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland | Veterans Integrated Service Network 10 | Total Small Business | |
| 657A5-26-111, Triennial Electrical Testing | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business Sole Source | |
| J061--triennial electrical maintenance FY26 amendment #3 q&a response, scope update, drawings and panel lists new deadline: 10/27/26 POP start date: 12/01/2026 | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity