H345--648-25-3-5098-1449 Boiler Condition Assessment

Closed Pre-Solicitation Posted

Solicitation number
36C26025Q0618
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Portland VA Medical Center Portland OR 97239

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 20 is conducting market research through a Sources Sought Notice for a comprehensive Boiler Condition Assessment at the Portland VA Medical Center. The procurement seeks a professional engineering firm to perform detailed inspection and assessment of three aging Cleaver Brooks boilers (500HP units from 1984) along with associated equipment including a deaerator tank and condensate tank. Qualified contractors must hold NAICS code 541380 (Testing Laboratories and Services) and possess certified boiler inspectors and non-destructive testing personnel capable of conducting visual inspections, ultrasonic thickness testing, and magnetic particle testing. The selected contractor must calculate remaining equipment life and produce a comprehensive report stamped by a licensed professional engineer. Interested businesses must submit their responses by June 23, 2025, at 3:00 PM EST, demonstrating their small business program eligibility, capabilities, past performance, and estimated project timeline.

This opportunity is designated as a Total Small Business set-aside with a size standard of $19 million for the applicable NAICS code. The assessment involves three 500-horsepower boilers that have been in service since 1984, indicating equipment that is over 40 years old and requiring thorough evaluation to determine remaining useful life. No incumbent contractors or current service providers are identified in the notice, suggesting this may be a new requirement or the first formal assessment of these aging systems. The VA will utilize the market research responses to potentially shape a future competitive solicitation for the actual boiler condition assessment services. While no specific contract value or budget range is disclosed in this pre-solicitation phase, the scope involves comprehensive non-destructive testing and professional engineering analysis that typically represents significant specialized technical services.

Notice text

Boiler Condition Assessment

Files

File Type Posted
36C26025Q0618.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
4820--Boiler Blow-Off Valves - STC St. Cloud VA Medical Center 4801 Veterans Drive · NAICS 332919 Veterans Integrated Service Network 23 No set-aside
J041--Building 2 Steam Station Replacement West Haven Vamc West Haven CT 06516 · NAICS 238220 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business
H945--Boiler Controls Inspection and Testing NAICS 541350 Veterans Integrated Service Network 10 No set-aside
J041--Condensate Pump Replacement West Haven Vamc West Haven CT 06516 · NAICS 238220 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business
Z1DA--Project 695-24-107 Replace Boilers 4 and 5 Clement J. Zablocki, VA Medical Center 5000 West National Avenue Milwaukee, WI 53295 United States · NAICS 238220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors