H341--Fire and Smoke Damper Location Survey

Closed Solicitation Posted

Solicitation number
36C24122Q0481
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
541350 Building Inspection Services

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

The following clarification information is being added:Â Â

This is not the TJC (The Joint Commission) or NFPA required fire and smoke damper maintenance and testing, this is as stated in the SOW a contract to locate and document the existence of the fire and smoke dampers. The previously completed TJC/NFPA report is very out of date and numerous projects have been completed since the last report rendering any lists or compiled documents inaccurate and incomplete.

Â

Refer to SOW (excerpt below) for ICRA information, if the conditions in the SOW are followed, no containment booth should be required, IC risk assessment attached for record:

Only two ceiling tiles at a time may be dislodged as part of the survey effort.

No open ceiling tile/access panel or ladder may be left unattended.

Do not open ceiling tiles in a patient space while patient is in the space. Coordinate with the COR when ceiling tiles need to be accessing in occupied inpatient spaces.

Cover working surfaces with plastic in the following areas prior to opening ceiling tiles or access panels.

B200

3W, Same Day Surgery

4N Chemo

5S Endo, 5N Dental

B200E

1st Nuc Med, SPS

3rd OR/IR

The following table displays the approximate square footages for the buildings and floors.

BUILDING

BASEMENT

1ST FLOOR

2ND FLOOR

3RD FLOOR

4TH FLOOR

5th FLOOR

6th FLOOR

7/8 FLOORS

TOTAL SF

Â

Â

Â

Â

Â

Â

Â

Â

Â

Â

B200E

(G) 38,939

29,881

31,068

31,881

11,076

Â

Â

Â

142,845

B200

(G)19,644

(w/mri) 30933

22,741

20,206

20,215

19,990

12,515

6,499/ 1,520

154,263

B203

Â

6,127

6,127

5,054

Â

Â

Â

Â

17,308

B204

1,012

16,606

15,624

962

Â

Â

Â

Â

34,204

B205

Â

19,753

19,775

19,770

1,829

Â

Â

Â

61,127

B206

Â

20,918

19,377

19,531

1,829

Â

Â

Â

61,655

B207

Â

19,765

20,621

20,586

3,138

Â

Â

Â

64,110

B210

2,698

8,941

1,623

2,866

Â

Â

Â

Â

16,128

B232

Â

14,866

3,655

Â

Â

Â

Â

Â

18,521

B248

Â

15,358

15,358

15,227

Â

Â

Â

Â

45,943

Update #1 ·

Fire and Smoke Damper Location Survey

Files

File Type Posted
36C24122Q0481 0001.docx DOCX document
IC Risk Assessment.pdf PDF
LS Drawings.pdf PDF
PWS Drawings.pdf PDF
WD-2015-4009.pdf PDF
36C24122Q0481.docx DOCX document
Past Performance Worksheet.xlsx XLSX spreadsheet
LOS Certification.pdf PDF

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
H341--Fire and Smoke Damper Location Survey Original Pre-Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors