FOR IN

FORMATION ONLY

LOCATION MAP

TRUE

NORTH

DRAWING TITLEDWG

NO.

INDEX OF DRAWINGS

DRAWING TITLEDWG

NO.

STATEMENT OF CONDITIONS

& LIFE SAFETY ASSESSMENT

FINAL SUBMITTAL

VA MAINE HEALTHCARE SYSTEM

1 VA CENTER,

AUGUSTA, ME 04330

AREA MAP

TRUE

NORTH

MAIN CAMPUS

COVER PAGE - G001

ALL

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

FP&C Project Number 3259.00

G001

08/18/2021 AF TK/KW

WALL:

DUCTS:

PENETRATIONS:

DOORS*:

WALL:

DUCTS:

DOORS:

WALL:

DUCTS:

PENETRATIONS:

DOORS:

SUITE DESIGNATION

2-HOUR FIRE BARRIER

THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS OF

4 OR MORE STORIES.

2-HOUR FIRE AND SMOKE ZONE BARRIER

THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND

STAIRWELLS OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION

OF THE 2-HOUR RATED WALL IS ALSO PART OF THE SMOKE WALL.

1-HOUR FIRE BARRIER

THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPERATIONS, HAZARDOUS ROOM

ENCLOSURES PER NFPA 101 8.6.5(2) AND STAIRWELLS 3 STORIES OR LESS. PER NFPA 101 19.3.2.1

SMOKE ZONE BARRIER

SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR

DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS

OF MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND

THE BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE

REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.7.6) SMOKE

ZONE BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED

TO BE OF A 12 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)

(COLOR #5)

(COLOR #4)

(COLOR #1)

(COLOR #2)

(COLOR #3)

NOTE: ALL CODE REFERENCES ARE PER THE 2018 EDITION OF NFPA 101 LIFE SAFETY CODE AND 2019 EDITION OF NFPA 80 AND NFPA 105. FEDERAL FACILITIES FOLLOW 2018 LIFE SAFETY CODE.

DOORS: DOORS THAT ARE NOT PART OF A RATED WALL:

1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1, 19.3.6.3 & 19.3.6.3.3)

2. NON-RATED DOORS PERMITTED IF SPRINKLERED (NFPA 101

18.3.6.3.1, 19.3.6.3.2(2))

3. 20-MINUTE OR SOLID WOOD CORE DOOR IF NOT SPRINKLERED (NFPA 101 19.3.6.3.1) 1 3 4" THICK.

4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER AND SINK

CLOSETS (NFPA 101 18.3.6.3.6 & 19.3.6.3.6)

5. SELF-CLOSING NOT REQUIRED (NFPA 101 19.3.6.3.11)

6. NO MAXIMUM GAP (NFPA 101 18.3.6.3.1 & 19.3.6.3.3)

7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)

8. UNLIMITED HEIGHT PROTECTIVE PLATE (NFPA 101 18/19.3.6.3.12)

9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS,

SHOWER AND SINK CLOSETS (NFPA 101 18/19.3.6.4)

10. SWING IN ANY DIRECTION

11. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.5.1)

(COLOR #30)

NON-RATED SMOKE ZONE PARTITION

FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER

ZONE. BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY

THE FIRE DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99-2018 EDITION AND PRIVATE

MODE AUDIBLE REQUIREMENTS OF SECTION 16.7.4.3 OF NFPA 72-2019 EDITION.

WALL:

DUCTS:

PENETRATIONS:

DOORS:

HEALTH CARE OCCUPANCY CORRIDORS

THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED TO LIMIT TRANSFER OF SMOKE.

PENETRATIONS:

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 2-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED TO

BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY

REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.

ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)

3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 TABLE 4.4.5)-LIMITED TO MAX AREA

TESTED.

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)

10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).

11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST

ANNUALLY (NFPA 80 5.2.4.1)

* 2 HOUR DOOR REQUIRED FOR STAIRWELLS 4 OR MORE STORIES (NFPA 101

7.1.3.2.1)(3).

WALL:

DUCTS:

PENETRATIONS:

DOORS:

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND

SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE

ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY QUICK

RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP

MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL

PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE

WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON

THE TOP OF THE FLOOR.

ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)

3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80

6.4.5.1)

10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).

11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT

LEAST ANNUALLY (NFPA 80 5.2.4.1)

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY FIRE

DAMPERS.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 1-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED

TO BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY

REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.

ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 80 4.3.1)*

3. MAXIMUM AREA TESTED WINDOW (NFPA 80 TABLE 4.4.5)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)

10.SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).

11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST

ANNUALLY (NFPA 80 5.2.4.1)

* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3 STORIES OR

LESS. (NFPA101 7.1.3.2.1)(1)

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS. SMOKE

DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS ARE

PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH

COMPARTMENT.

ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES. PENETRATIONS ARE

TO BE FILLED ON BOTH SIDES OF THE WALL.

ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:

1. NON-LABELED FRAME (NFPA 101 18.3.7.6)

2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6) 1 3 4" THICK.

3. MAXIMUM SIZE LISTED WINDOW (NFPA 80 TABLES 4.4.5)

4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)

6. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

7. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4)

8. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1

9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)

10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105

5.2.5.1)

WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.

NO MINIMUM REQUIREMENTS.

NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A SUSPENDED

CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR DECK SEALED

WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.

NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC CLOSING

IN AN EMERGENCY.

(COLOR #30)

(COLOR #2)

HEALTHCARE AREA OPEN TO CORRIDOR WITH 24

SUPERVISION - NO SMOKE DETECTION REQUIRED.

(COLOR #3)

HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE

DETECTION PROVIDED.

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

(COLOR #230)

(COLOR #4)

NON-FIRE RATED SMOKE BARRIER

SUBSTANTIAL WALLS AND DOORS TO SUBDIVIDE BUILDING SPACES FOR THE PURPOSE

OF RESTRICTING THE MOVEMENT OF SMOKE.

WALL: EXTENDS FROM FLOOR TO DECK ABOVE.

DUCTS: SMOKE DAMPERS ARE NOT REQUIRED WHERE STEEL DUCTS PENETRATE SMOKE

BARRIERS FORMING A COMMUNICATING SPACE SEPARATION.

PENETRATIONS: ALL PENETRATIONS ARE SEALED WITH NON-FIRE RATED MATERIALS TO PREVENT THE

TRANSFER OF SMOKE. USE OF LISTED FIRE STOP MATERIALS IS NOT REQUIRED.

DOORS: ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:

1. NON LABELED FRAME (NFPA 101 8.5)

2. NON FIRE RATED DOOR (NFPA 101 8.5)

3. NO GRILLS OR LOUVERS ARE PERMITTED (NFPA 101 8.5.1)

4. POSITIVE LATCHING HARDWARE IS REQUIRES (NFPA 101 8.5.4.3)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 8.5.4.43)

6. MAXIMUM ¾” UNDERCUT (NFPA 101 8.5.4.1)

7. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1)

8. SWING IN ANY DIRECTION (NFPA 8.5)

9. WINDOW ASSEMBLIES ARE NOT REQUIRED TO BE FIRE RATED (NFPA 8.5)

10. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.5.1)

WALL:

DUCTS:

DOORS:

SMOKE RESISTIVE ENCLOSURE

(COLOR #230) IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED TO LIMIT

TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE RATING AND MAY

TERMINATE AT THE CEILING PER NFPA 101 8.4.2(3). IF THE ROOM DOES NOT

HAVE A SUSPENDED CEILING, THE WALL HAS NO FIRE RESISTANCE RATING

AND SHALL EXTEND TO THE DECK ABOVE PER NFPA 101 19.3.2.1.2.

STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE

DAMPERS OR SMOKE DAMPERS.

SEALED WITH NON-FIRE-RATED MATERIALS TO BE RESISTIVE. USE OF LISTED

FIRESTOP MATERIALS IS NOT REQUIRED.

EXISTING HAZARDOUS ROOMS:

1. NON-LABELED FRAME (NFPA 101 8.4.2)

2. 20 MINUTE OR SOLID WOOD CORE (NFPA 105 A.6.3.1) 1 3 4" THICK.

3. POSITIVE LATCHING IS REQUIRED PER (NFPA 105 6.3.4)

4. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)

5. MAXIMUM 1/8" GAP (NFPA 105 6.3.3)

6. MAXIMUM 3 4" UNDERCUT (NFPA 80 4.8.4.1)

7. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.4)

8. SWING IN ANY DIRECTION

9. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA

105 5.2.5.1)

PENETRATIONS:

(COLOR #30)

EXIT STAIRWELL/PASSAGEWAY

ALL

FIRE/SMOKE BARRIER

DESCRIPTION

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

FP&C Project Number 3259.00

SOC X-1

APPLICABLE CODES AND STANDARDS: FIRE SPRINKLER SYSTEM:

1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO NFPA 13 AND NFPA 14.

2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS (NFPA 13 - 3.3.4.16).

3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 225 SQ. FT. (NFPA 13 - TABLE 19.3.3.1.2).

4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR SHOPS AND STORAGE ROOMS UNDER 250 SQ. FT. AT A 0.15

GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 150 SQ. FT. (NFPA 13 - TABLE 19.3.3.1.2).

5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ. FT. DENSITY.

6. MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS SHALL NOT EXCEED 7'-6" (NFPA 13 - 10.2.5.2.1). MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS IN SMALL ROOMS (800 SQ. FT. MAXIMUM) SHALL NOT

EXCEED 9' FROM ANY SINGLE WALL (NFPA 13 - 10.2.5.2.3).

7. SPRINKLERS SHALL BE INSTALLED UNDER FIXED OBSTRUCTIONS (I.E. DUCTWORK) OVER 4' WIDE (NFPA 13 - 12.1.10.3.2). THE WIDTH OF DUCT INSULATION NOT A FACTOR FOR SPRINKLERS INSTALLED PRIOR TO THE 2019 EDITION ON NFPA 13. SPRINKLERS NOT REQUIRED UNDER

NON COMBUSTIBLE OBSTRUCTIONS OVER 4' WIDE WHERE THE BOTTOM OF THE OBSTRUCTION IS A MAXIMUM 24" ABOVE THE FLOOR (NFPA 13 - 9.5.5.3.1).

8. SPRINKLERS SHALL BE INSTALLED A MAXIMUM 12" BELOW A CEILING OR FLOOR/ROOF DECK (NFPA 13 - 10.2.6.1.1.1) OR A MAXIMUM 22" BELOW A FLOOR/ROOF DECK WITH STRUCTURAL MEMBER OBSTRUCTIONS (NFPA 13 - 10.2.6.1.2).

9. SHELVING ON A WALL OR SHELVING AGAINST A WALL INCLUDING STORAGE THEREON SHALL BE PERMITTED TO EXTEND WITHIN THE 18" SPRINKLERS CLEARANCE BELOW CEILING SPRINKLER DEFLECTORS (NFPA 13 - 9.5.6.1).

10. WHERE THE 18" CLEARANCE BETWEEN SPRINKLERS AND SHELVING STORAGE CANNOT BE MAINTAINED, SPRINKLERS SHALL BE INSTALLED IN EVERY AISLE PER NFPA 13 - 9.2.5(2).

11. CEILING MOUNTED OBSTRUCTIONS (I.E. PATIENT LIFT TRACKS) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 - TABLE 10.2.7.1.2 AND FIGURE 10.2.7.1.2(a).

12. FLOOR MOUNTED OBSTRUCTIONS (I.E. ROOM DIVIDERS OR SHELVING) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 - TABLE 10.2.7.2.2 AND FIGURE 10.2.7.2.2.

SUITES:

1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR AISLES AND TO DEFINE THE END OF PUBLIC EXIT

CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE SUITE MAY DIRECT OCCUPANTS INTO A SUITE TO REACH AN EXIT.

2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.

3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:

A. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2)

B. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)

C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS OR COMPLETE SMOKE DETECTION - 7,500 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.B) D. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION - 10,000 SQ. FT. (NFPA

101 - 19.2.5.7.2.3.C)

4. PATIENT CARE NON - SLEEPING SUITES:

A. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.1.B)

B. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.3.3)

5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.

6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6

OF NFPA 101.

1. THE ORIGINAL BUILDING WAS DESIGNED TO THE 1943 EDITION OF NFPA 101, LIFE SAFETY CODE.

2. THE 1960 PUBLIC BUILDING AMENDMENT ACT (PL100-678) REQUIRES ALL FEDERAL AGENCIES TO FOLLOW THE LATEST EDITIONS OF NATIONALLY

RECOGNIZED FIRE AND LIFE SAFETY CODES. THE VA HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2018 EDITION OF NFPA 101, LIFE SAFETY CODE.

3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE LATEST EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE CODES AND STANDARDS.

4. OTHER NFPA CODES AND STANDARDS:

A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2018 EDITION

B. NFPA 13 - SPRINKLER SYSTEMS, 2019 EDITION

C. NFPA 14 - STANDPIPE SYSTEMS, 2016 EDITION

D. NFPA 20 - FIRE PUMPS, 2019 EDITION

E. NFPA 25 - WATER-BASED FIRE PROTECTION SYSTEMS 2020 EDITION

F. NFPA 70 - NATIONAL ELECTRIC CODE, 2020 EDITION

G. NFPA 72 - NATIONAL FIRE ALARM CODE, 2019 EDITION

H. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2017 EDITION

I. NFPA 80 - FIRE DOORS, 2019 EDITION

J. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2018 EDITION

K. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2017 EDITION

L. NFPA 99 - HEALTH CARE FACILITIES CODE, 2018 EDITION

M. NFPA 105 - SMOKE DOORS, 2019 EDITION

N. NFPA 110 - EMERGENCY POWER SYSTEMS, 2019 EDITION

O. NFPA 241 - CONSTITUTION AND DEMOLITION, 2019 EDITION

1. EXITS (STAIRWAYS, HORIZONTAL EXITS AND DIRECT EXTERIOR EXIT DOORS), OTHER THAN EXTERIOR EXIT DOORS THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIABLE AS EXITS. (GLASS DOORS, VISION PANELS OR ADJACENT WINDOWS) SHALL BE MARKED WITH EXIT SIGNAGE.

(SECTION 7.10.1.2.1 OF NFPA 101-2018 EDITION)

2. DIRECTIONAL SIGNS REQUIRED WHERE DIRECTION OF TRAVEL IS NOT APPARENT IN AN EXIT ACCESS CORRIDOR. (SECTION 7.10.2.1 OF NFPA

101-2018 EDITION)

3. DIRECTIONAL SIGNAGE (EXIT PLACARDS) REQUIRED WITHIN HORIZONTAL COMPONENTS OF EXIT STAIR ENCLOSURES WHERE EGRESS PATH

IS NOT OBVIOUS (SECTIONS 7.10.2.2 AND 7.10.1.2.2 OF NFPA 101-2018 EDITION)

4. MAXIMUM VIEWING DISTANCE TO AN EXIT SIGN IN AN EXIT ACCESS CORRIDOR IS 100 FT. (SECTION 7.10.1.5.2 OF NFPA 101-2018 EDITION)

5. EXIT SIGNS SHALL BE INSPECTED MONTHLY. (SECTION 7.10.9.1 IF NFPA 101-2018 EDITION)

6. DIRECTIONAL SIGNAGE (EXIT PLACARDS OR EXIT SIGNS) WITH OR WITHOUT DIRECTIONAL ARROWS SHOULD BE PROVIDED IN SUITES USED

BY THE GENERAL PUBLIC (LESS THAN 50 TOTAL OCCUPANTS) TO DIRECT THE GENERAL PUBLIC BACK TO THE WAITING AREA. (SECTION

7.10.2.1 OF NFPA 101-2018 EDITION)

7. ROOMS OR SUITES OF ROOMS USED FOR 50 OCCUPANTS OR MORE SHALL BE PROVIDED WITH EXIT SIGNAGE. (SECTIONS 13.2.10.1 AND

3.3.196.2 OF NFPA 101-2018 EDITION)

EXIT SIGN REQUIREMENTS

OCCUPANCY TABLE

FIRE ALARM SYSTEM:

1. THE FIRE ALARM SYSTEM WAS DESIGNED TO NFPA 72, NATIONAL FIRE ALARM CODE.

2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA 101-2018 EDITION.

3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN CORRIDORS AND LARGER ROOMS OR SUITES PER SECTION 18.4.4.1 OF NFPA

72 - 2019 EDITION.

4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT REDUCED QUANTITY AND SPACING PER SECTION 18.6 OF THE NFPA 72 - 2019

EDITION.

5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN ACCORDANCE WITH SECTION 18.5.4.3.2(3) OF NFPA 72 - 2019 EDITION.

6. TYPICAL SMOKE DETECTORS HAVE A 21 FT. RADIUS OF COVERAGE AREA (NFPA 72 - 17.7.3.2.3.1)

7. SMOKE DETECTORS THAT ARE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND LOCATED ON BOTH SIDES OF SMOKE/FIRE DOORS MAY

BE SPACED AT MAXIMUM 21' RADIUS FOR DOOR RELEASE SERVICE (NFPA 72 - 17.7.5.6.1) SMOKE DETECTORS NOT CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND USED EXCLUSIVELY FOR SMOKE/FIRE DOOR RELEASE SHALL BE LOCATED AND SPACED PER NFPA 72- 17.7.5.6.

8. CEILINGS WITH BEAM DEPTHS OF LESS THAN 10% OF CEILING HEIGHT SHALL BE CONSIDERED A SMOOTH CEILING FOR SMOKE DETECTOR COVERAGE. CEILINGS WITH BEAM DEPTHS GREATER THAN 10% OF CEILING HEIGHT SHALL HAVE REDUCED SMOKE DETECTOR SPACING

COVERAGE (NFPA 72 - 17.7.3.2.4.2).

9. SMOKE DETECTORS SHALL BE LOCATED ON THE CEILINGS THE BOTTOM OF BEAMS OR MAXIMUM 12" DOWN FROM THE CEILING TO TOP OF THE

DETECTOR (NFPA 72- 17.7.3.2.1).

10. SMOKE DETECTORS SHALL NOT BE LOCATED DIRECTLY IN THE AIR STREAM OF SUPPLY AIR REGISTERS (NFPA 72- 17.7.6.3.2).

THE VA HAS ELECTIVE ACCREDITATION WITH THE JOINT COMMISSION (TJC) FOR HEALTH CARE FACILITIES. SEE THE MEMORANDUM OF UNDERSTANDING (EFFECTIVE JANUARY 31, 2020) BETWEEN THE VA AND TJC FOR IMPLEMENTATION OF TJC ENVIRONMENT OF CARE (EC) AND

LIFE SAFETY (LS) STANDARDS.

THE VA HAS ELECTIVE ACCREDITATION WITH THE LONG-TERM CARE INSTITUTE, INC. (LTCI) FOR COMMUNITY LIVING CENTERS (CLC). SEE THE CLARIFICATION MEMORANDUM (EFFECTIVE MARCH 12, 2019) BETWEEN THE VA AND THE LTCI FOR IMPLEMENTATION OF LIFE SAFETY

REQUIREMENTS.

THE FOLLOWING NATIONWIDE VA EQUIVALENCIES HAVE BEEN REVIEWED AND APPROVED BY THE JOINT COMMISSION AND APPLY TO ALL BUILDINGS:

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON FIRE RATED DOORS

2. BUSINESS OCCUPANCY DEAD END CORRIDORS PERMITTED TO EXCEED 50 FEET

3. INTERNAL SPRINKLER PIPING CONDITION AND OBSTRUCTION INVESTIGATION.

EQUIVALENCIES

Building No. Floor Health Care Ambulatory Health

Care Business Industrial Domiciliary Total 200 Ground 17,907 2,478 20,385

200 1 28,929 28,929

200 2 20,530 20,530

200 3 18,177 18,177

200 4 18,075 18,075

200 5 5,915 8,225 14,140

200 6 9,360 9,360

200 7 5,977 5,977

200 Penthouse 1,359 1,359

SUB TOTALS 36,252 5,915 90,928 3,837 0 136,932

200E Ground 37,316 37,316

200E 1 28,325 28,325

200E 2 30,286 30,286

200E 3 29,691 29,691

200E Penthouse 7,656 7,656

SUB TOTALS 29,691 37,316 58,611 7,656 0 133,274

206 1 19,673 19,673

206 2 18,306 18,306

206 3 18,420 18,420

206 Penthouse 1,550 1,550

SUB TOTALS 18,420 0 39,529 0 0 57,949

207 1 18,383 18,383

207 2 19,199 19,199

207 3 19,180 19,180

207 Penthouse 2,873 2,873

56,762 0 0 2,873 0 59,635

GRAND TOTALS 141,125 43,231 189,068 14,366 0 387,790

ALL

CODE SUMMARY AND

OCCUPANCY TABLE

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

FP&C Project Number 3259.00

SOC X-2

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

EXEX

B 200

B 200E

GROUND SOUTH GROUND NORTH

GROUND CENTER

GROUND NORTH

BUSINESS OCCUPANCY

FULLY SPRINKLERED

GROUND FLOOR

BUILDING 200

N

BUILDING 200 GROUND FLOORCONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200SOC-G

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

145A

137A

157A

166A

195A

166B

166D 166C

C102 C101

102 104

176A

2A

101 105 107 109

115 111 117 119

123 125

122 120 114 112 108

101A

116 118

142B

SI

LL

H T

M114

M112

M113

M111

M109

M110

M115M101

M107

M105 M108

M106

M100M104

M103

M120 M119 M118 M117 M116

147145A

175A

129B

142B

155B

150142A 142B

A

142B

SMOKE DOORS

155A

155155C

155D

MRI

159A

142C

141A

SILLHT SILLHT

C101A

C101B

102A

1'-8"

PARKING FOR

PORTABLE M/C

ORTHOPEDICS

SPD STORAGE

TOILET

MALE TOILET

ELECTRICAL

TOILET

ULTRA SOUND

DATA RM

PARKING FOR

PORTABLE M/C

ELECTRICAL

ELECTRICAL

TOILET

HAC

HAC

TOILET

WAITING

CHANGING RM

WAITING

CHANGING

RM

CORRIDOR

CORRIDOR

CORRIDORCORRIDOR

CONTROL RM

CT SCANS

ELECTRICAL RM

CT SCAN

EXAM RM EXAM RM

RECEPTION WAITING

OFFICE OFFICE EXAM RM EXAM RM

PHYS ADMIN

OFFICE

EXAM RMEXAM RMEXAM RM

BREAK RM

STORAGE

VESTIBULE

STAIR

STORAGE

SOILED

BIO-WASTE

SUPPLYCAST / EXAM RMLOCKER

CORRIDOR

CORRIDOR

STAIR - E

CORRIDOR

TEL

CHUTE

SOILED LINEN

STAIR

FIRE

ALARM

STORAGE

ELECTRICAL EQUIP

STORAGE

CRAWL SPACE

EMERGENCY GENERATOR

PUMP RM

COOLER

BLUE RM

LAB

CORRIDOR

OXYGEN

STORAGE

STORAGE

HISTOLOGY

STORAGE

COMP

GAS

STORAGE

STAIR

TRASH UNIT

HISTOLOGY

OXYGEN

STORAGE

HISTOLOGY LAB

RECEPTION AREA

CORRIDOR

ELECTRICAL

CLOSET

ELEVATOR

ELEVATOR

ELEVATOR

CLEAN

SUPPLY

TOILET

ULTRASOUND SUITE

ULTRA SOUND

BREAK RM

LOCKER

ROOM

PLUMBER

OFFICE

MECH

STRECHER

WC WAITING

X-RAY - 1

X-RAY - 2LIGHT RM

X-RAY - 3

PREP RM

X-RAY - 4

X-RAY - 5

CONTROL RM

CORRIDOR

LOCKER

WAITING

STORAGE

RECOVERY RM EMS

STORAGE SUPPLY

READING RM

OFFICE

STAIR

STORAGE

VESTIBULE

COMPUTER RM

MRI SCAN RM

TOILET

RECEPTION

OFFICE

TOILET

TOILET

OFFICE

OFFICE

EXAM RMEXAM RM

ELEC CLOS

BONE DENSITOMETRY

RADIOLOGY MGR

OFFICE

LINEN RM HAC

NITROGEN

STORAGE

STORAGE

MECH

DARK ROOM

EMS STORAGE

STORAGE

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

129A

UNDER

RENOVATION

LC

EX

EXEX

1 WEST

1 NORTH

1 SOUTH 1 NORTH

EX

OPEN DOCK

OPEN DOCK

1 WEST

1 SOUTH

C106 C107

C120

C105

C103 E133A

C120

C80

C104

C120

C104A

MENS

TOILET

WOMENS

TOILET

CONFERENCE

TRAVEL OFFICE

TEL CLOS

OFFICE

OFFICE

C

9 E131

C107

E133

MENS

TOILET

PHARMACYHAC

OFFICE

B 200

B 200E

1 CENTER

1 SOUTH

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200SOC-1

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

BUSINESS OCCUPANCY

FULLY SPRINKLERED

FIRST FLOOR

BUILDING 200

N

BUILDING 200 FIRST FLOOR

270E

270E1

270F

270A

270B

270D

270C

264A

264B

262A

262B

265A

257 251

C201

C202

280A

234 240

K

233 235 237 239 241 243 245

280B

258 256

242 244

230A

ICE

ICE

UP

DN

CORRIDOR

ELEVATORELEVATORELEVATOR

SILLHTSILLHT

SILLHT

S I L

L H

T

S

I

L

L

H

T

S I L

L H

T

S

I

L

L

H

T

S I L

L H

T

S

I

L

L

H

T

S I L

L H

T

S I L

L H

T S

I L

L H

T

SILLHT SILLHT

C201A

C201B

201D201C201B 201A 203

201E 205A

205 207 209

218216214212210

206204

208C

208B

208A

283282

208D

ELECTRICAL

ELECTRICAL

VASCULAR

STORAGE

COM

CORRIDOR

STAIR-D

CORRIDOR

CORRIDOR

TEL

CLOSET

LAB MGR

OFFICE

PATHOLOGY

LAB

OFFICE OFFICE

OFFICE

LOCKER

RM

KITCHEN

BIO

SAFETY

OFFICEBLOOD

BANK

OFFICE

LAB

VEST

STORAGE

LAB

CHEMISTRY

LAB

TOILET

OFFICE

HEMATOLOGY

LAB

BLOOD DONOR

RM

OFFICE

CONFERENCE

HACTOILET

ELECTRICAL

ELEVATOR

ELEVATOR

ELEVATOR

STAIR-E

CORRIDOR

PRE

EQUIP

CLEANING

EXAM RMEXAM RMEXAM RMEXAM RMEXAM RMSTORAGE

TOILET

SUPPLY RM

HAC

VASCULAR

EXAM RM

VASCULAR

EXAM RM

STAIR-C

BREAK RM

EXAM RM

EXAM RMOFFICE

PROCEDURE RM

TOILET

PROCEDURE

RM

EXAM RM

EXAM RM

OPEN OFFICE

WAITING

EYEGLASS

STAIR-1

ELECTRICAL

STORAGE

ELECTRICAL

DIRTY

LINEN

CLEAN

LINEN

SPD

STORAGE

STORAGE

STAFF

ROOMPATIENT

BATH

STAFF

BATH

HAC ELECT

WAITING

OFFICE EXAM WAITING

TELE

HEALTH

STAFF

STORAGERECEPTION

STORAGE

WAITING

MECHANICAL

OFFICE

LAB

WAITING

STAFF MECH STAFF

EXAM EXAM

CORRIDORCORRIDOR

SHAFT

SHAFT

SHAFT

LAUNDRY

CHUTESILLHT SILLHT

2 CENTER 2 NORTH

2 SOUTH 2 CENTER

EXAM RM EXAM RM

NEW

FLOORPLAN

C204 C220

CONFERENCE

ROOM

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

B 200

B 200E

LC 2 WEST

2 CENTER

2 CENTER

2 SOUTH

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200SOC-2

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

BUSINESS OCCUPANCY

FULLY SPRINKLERED

SECOND FLOOR

BUILDING 200

N

BUILDING 200 SECOND FLOOR

KEY NOTES:

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

SZ-200-3-NORTH

SZ-200-3-SOUTH SZ-200-3-CENTER

SZ-200-3-WEST

SZ-200-3-CENTER

SZ-200-3-CENTER

TEL CLOSET

OFFICESZ-200-3-CENTER

B 200E

B 200

SZ-200E-3-CENTER

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200SOC-3

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

HEALTH CARE OCCUPANCY

FULLY SPRINKLERED

THIRD FLOOR

BUILDING 200

N

BUILDING 200 THIRD FLOOR

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

SMOKE ZONE SQ. FT. OCCUPANCY

SMOKE ZONE SIZE

CLEAN

LINEN

ASST CHIEF CONFERENCE RM

ELECTRICAL

TOILET

STORAGE

CHASE

TELECOM

BATH

TOILET

MED RM

OFFICE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

HAC

BATH

ELEVATOR

ELEVATOR

ELEVATOR

ELECTRICAL

CARDIOLOGY

OFFICE

EXAM RM

ECG

HAC

TOILET

ECG

STRESS

TESTING

ULTRA SOUND

ECHO

CARDIOLOGY TECH

OFFICE

STAIR-D OFFICE MED SVC

CHIEF

MED SVC

OFFICE

OFFICE

EXAM RM

OFFICE

OFFICE

CHIEF

STAIR

TOILET

HAC

INFUSION OFFICE

TOILET

CHEMOTHERAPY CHEMOTHERAPY

STAIR

ONCOLOGY CARE

CO-ORDR OFFICE

INFUSION

TOILET

INFUSION

STORAGE

EXAM

NURSE

STATION

ENDOCRINOLOGYWAITING

RECEPTION

EXAM RM

ONCOLOGY

OFFICERHEUMATOLOGY

OFFICE

OFFICE

CLEAN

LINEN

TOILET

SPD STORAGE

FAMILY RM

EXAM RM

CLEAN

STORAGE

CONFERENCE RM

ELECTRICAL

OFFICE

TOILET

DRESSING

RM

EEG

ROOMOFFICE

STORAGE

STORAGE

OFFICE

ELECTRICAL

HAC

OFFICE

OUPATIENT CHEMO INFUSION SUITE

OUTPATIENT SUITE NON

SLEEPING, 4,904SF

SZ-200-4-CENTER SZ-200-4-NORTHSZ-200-4-SOUTH SZ-200-4-CENTER

VACANT

LC

SZ-200-4-WEST

SZ-200-4-CENTER

DAY ROOM

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

B 200

B 200E

SZ-200-4-CENTER

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200SOC-4

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

HEALTH CARE OCCUPANCY

FULLY SPRINKLERED

FOURTH FLOOR

BUILDING 200

N

BUILDING 200 FOURTH FLOOR

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

ELECTRICAL

STORAGE

SOILED

LINEN

TEL

CORRIDOR

CORRIDOR

VESTIBULE

CORRIDOR

LOBBY

ELECTRICAL

ELEVATOR

ELEVATOR

ELEVATOR

MECH

RM

STAIR

X-RAY

DENTAL

OFFICE

OFFICE

OFFICE

OPERATORY

SUPPLY

STAIR

ORAL

SURGY

OPERATORY

PATIENT

TOILET

SOILED

UTILITY

CLEAN

SUPPLIES

CORRIDOR

CONFERENCE/

BREAK RM STAFF

TOILET

WOMENS

LOCKER

MENS

LOCKER

OPERATORY

STAIR

OPERATORY RESIDENT

OPERATORY

RESIDENT

OPERATORY

DENTAL

LAB

RESIDENT

OPERATORY

RESIDENT

OPERATORY

SUPPLY

CLOSET

OPERATORY

RM

OPERATORY

RMOPERATORY

PANOGRAPHY

RM

HAC

CHIEF

OFFICE

RECEPTION

LINEN

WAITING

AREA

STORAGE

ELECTRICAL

CLOSET

ELEVATOR

LOBBY

ELEVATORELEVATORELEVATOR

CLINICAL

DIETITIANS

OFFICE

STAIR-1

PROCEDURE

ROOM

PROCEDURE

ROOM

PROCEDURE

ROOM

STAIR

DRESSING

RM

DRESSING

RM

DRESSING

RM

WAITING

NURSES

STATION

CORRIDOR

CORRIDOR

SOILED

UTILITY

DECON

ROOM

TREATMENT

ROOM

CLEAN

SCOPE

DRESSING

ROOM

STORAGE

OFFICE MECH

EXAM

LOUNGE

OFFICE

BATH

RECOVERY

BATH

SHAFTSHAFT

STORAGE

BATH

SZ-200-5 SOUTH 5 NORTH

AMBULATORY

HEALTHCARE

OCCUPANCY

BUSINESS

OCCUPANCY

5 WEST

5 NORTH

LC

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200SOC-5

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

MIXED OCCUPANCY

FULLY SPRINKLERED

FIFTH FLOOR

BUILDING 200

N

BUILDING 200 FIFTH FLOOR

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

ROOF

ROOF ROOF

SILLHTSILLHTSILLHT

636 637

604 606

608600

601A

627 621

620A

HAC

613615

644 632

SILLH

T

SOILED

UTILITY

ELECTRICAL

ELECTRICAL

STORAGE

CORRIDOR

CORRIDOR

CORRIDOR

GI

GASTROENTEROLOGY

OFFICE

SLEEP

LAB

CORRIDOR

CORRIDOR

AHU

(MECH)

WAITING

HAC

PULM

OFFICE

ELEVATORELEVATORELEVATOR

RECEPTION EXAM

RM

OFFICE EXAM

RM

EXAM

RM

EXAM

RM

APNEA

CLINIC

PFT

LAB

STORAGE

GI

EXAM

RM

SUPPLY

EXAM RMEXAM

RM

TOILETSTAIR-E

IT

CLOSET

TOILET

RESP

OFFICE

PULMONOLOGIST

DOCTOR

OFFICE

OFFICE

PULMONOLOGIST

DOCTOR

OFFICE

DIRTY

EQUIP

ELEVATOR

ELEVATOR

ELEVATOR

EQUIP

STORAGE

CLEAN

SUPPLY

SLEEP CONTROL

RM

MECH RM

TOILET

STAIR

GI EXAM RM

CHIEF

GASTROENTEROLOGY

(GI)

STAIR

SLEEP

LAB

TOILET

TOILET

SLEEP

LAB

SLEEP

LAB

TOILET

TOILET

SLEEP

LAB

CORRIDOR

SHAFTSHAFT

CHUTE

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

6 CENTER 6 NORTH6 SOUTH 6 CENTER

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200SOC-6

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

BUSINESS OCCUPANCY

FULLY SPRINKLERED

SIXTH FLOOR

BUILDING 200

N

BUILDING 200 SIXTH FLOOR

ELECTRICAL

ELECTRICAL

CLOSET

CORRIDOR

CTR CANCER

REGISTRAR

OFFICE

TOILET

TOILET

ON-CALL RM

TOILET

SOCIAL

WORKER

OFFICE

CORRIDOR

CORRIDOR

PROSTHETICS

FITTING RM

PROSTHETICS

CLINIC

STAIR

TOILET

WAITING

OFFICE

ELEVATOR

ELEVATOR

ELEVATOR

CHECK-IN

SUPPLY

OFFICE

OFFICE

OFFICE

CLOSET

ELEVATOR MACH RM

LAB PROS

STAIR-1

HAC

CLOSET

CHUTE

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

7 EAST

7 WEST

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200SOC-7

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

BUSINESS OCCUPANCY

FULLY SPRINKLERED

SEVENTH FLOOR

BUILDING 200

N

BUILDING 200 SEVENTH FLOOR

ROOF

ROOF

MECH

MECH

STAIR

ELEVATOR

MACH RM

DN

UP

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200SOC-8

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

INDUSTRIAL OCCUPANCY

FULLY SPRINKLERED

PENTHOUSE FLOOR

BUILDING 200

N

BUILDING 200 PENTHOUSE FLOOR

FEMALE TOILET

CLOSET

TOILET

TOILET

COAT CLOSETSTORAGE

ELECTRICAL

PUMP RM

TRAVEL CASHIER

STORAGE

OFFICE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

TRIAGE

CORRIDOR

LOCKER RM

E R E R

E R

OBSER/TREAT

LIFE SUPPORT RMVESTIBULE

AMBULANCE AREA

STAIR - 2

SPD

SUPPLY RMON CALL RM

TOILET

EXAM RM

EXAM RM

OFFICE

SWITCHGEAR RM

SWITCHGEAR RM

OFFICE

OFFICE

MALE

TOILET

ELECTRICAL

HAC

TRIAGEE R OFFICE

BLOOD DRAW TOILET

SOILED

UTILITY

EXAM

EXAM RM

EXAM RMCOPY RM

OFFICE EXAM RM

EXAM RMEXAM RM

NURSE MGR

OFFICE

EXAM RM

OFFICE

OFFICE

TELE HEALTH

STORAGE

WAITING AREA

SOCIAL

WORKER

OFFICE

PATIENT SVC

ASSTS

PROCESSING

AREA

OFFICE NURSE

MGR

OFFICE

OFFICE

AGENT

CASHIER

OFFICEOFFICEOFFICE

OFFICEOFFICE

ELECTRICAL

EXAM

STORAGE

OFFICE

OFFICE OFFICE

OFFICEOFFICE

OFFICEOFFICE

EXAM RMEXAM RM

OFFICE

EXAM RMHAC

EXAM/ PHYSICIAN

EXAM RM

OFFICE

OFFICEOFFICE

COPY RM

OFFICEOFFICE

EXAM RM

VOLUNTARY

SVC OFFICE

TEL CLOSET

FEMALE

TOILET

VACANTHAC

MALE TOILET

OFFICE OFFICE

LOBBY

WAITING

HBA CALL CTR

CORRIDORSTAIR - 3

VAULT

PHARMACY SVC

HAC

ELECTRICALBREAK RMOFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

PHARMACY

WINDOW INPUT

OFFICE WINDOW

INPUT

OUT PATIENT

PHARMACY

MGR OFFICE

CORRIDOR

EXAM RM

STORAGE

RECEPTIONRECEPTION

CORRIDORRECEPTION

RECEPTION

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

CORRIDOR

UNDER

RENOVATION

UNDER

RENOVATION

B 200

B 200E

EX

EX

EX

EX

GROUND CENTER SZ-200E-G-NORTH

EX

GROUND SOUTH GROUND CENTER

BUSINESS

OCCUPANCY

AMBULATORY

HEALTH CARE

OCCUPANCY

GROUND CENTER

GROUND NORTH

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200ESOC-G

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

MIXED OCCUPANCY

FULLY SPRINKLERED

GROUND FLOOR

BUILDING 200E

N

200E

BUILDING 200E GROUND FLOOR

MENS

TOILET

WOMENS

TOILET

HAC

DECONTAMINATION

LOCKER RM

TOILET

TOILET

DE-IONIZED WATER

TREATMENT

PROCESSING

STORAGE

ELEC CLO

PHARMACY

DIRTY UTILITY

CLEAN UTILITY

HAC

OFFICE

LOCKER

TOILET

OFFICE

CHEMO- THERAPY

STORAGE

CORRIDOR CORRIDOR

CONFERENCE

TRAVEL OFFICE

TEL CLOS

OFFICE

CORRIDOR

STAIR 2

BREAK RM

HAC

SPD DIRTY

SPD

ETD GAS

SPD CLEAN AREA

WASHER

DISINFECTOR

EQUIPT STORAGE

AND DISPENSINGSTORAGE

ELEC CLO

DW2

OFFICE

OFFICE

EXAM RM

GENERAL SURGY

GENERAL SURGY

TOILET

EXAMOFFICE

PROCEDURE

ROOM

CORRIDOR

STORAGE

MAS SEC

GENERAL SURGY

WAITING

NUCLEAR

MEDICINE

WAITING

RECEPTIONTOILET

ELEC

HAC

HAC

TOILET

INPT

PHARMACY

MGR OFFICE

PHARMACY

TEL CLOELEC

OFFICE

STAIR 3

CLINICAL

TEACHING

CO-ORDR

OFFICE

OFFICECHIEF OFFICE

VAULT

LAB

OFFICE

PROCEDURE

ROOM

PROCEDURE

ROOM

PROCEDURE

ROOM

CONTROL

ROOM

PROCEDURE

ROOM

OFFICE

CLEAN

LINEN

SPD

STORAGE

STORAGE

READING

ELEC

LAB

LAB

CORRIDOR

CORRIDOR

OFFICE

OFFICE

OFFICE

ELEC

DUMB WAITER

UTILITY

DUMB WAITER

UTILITY

UTILITY

UTILITYUTILITY

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

OFFICE

B 200

B 200E

1 CENTER 1 NORTH1 SOUTH 1 CENTER

1 CENTER

1 SOUTH

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200ESOC-1

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

BUSINESS OCCUPANCY

FULLY SPRINKLERED

FIRST FLOOR

BUILDING 200E

N

200E

BUILDING 200E FIRST FLOOR

MENS

TOILET

WOMENS

TOILET

ELECTRICAL

SUPPLY RM

STORAGE

ELECTRICAL

CLOSET

CORRIDOR

CORRIDOR

WAITING

OT CLINIC

MECH RM

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

OFFICE

OFFICE

HAC

TEL

AUDIOLOGY

OFFICE

E N T WAITING

AREA

OFFICE

EXAM

AUDIOLOGIST

CORRIDOR

STAIR

SOUND

BOOTH

CONTROL

SOUND

BOOTH

CONTROL

BOOTH

EXAM RMEXAM RM

MICROSCOPE RM

SOILED

UTILITY

VISUAL

FIELD RM

PRE OP RM

ELECTRICAL

CLOSET

WAITING

EXAM RM

EXAM RM EXAM RM EXAM RM

EXAM RM

EXAM RM

TOILET

CORRIDOR

CONTROL

SOUND

BOOTH

AUDIOLOGY

STORAGEP T EXAM RM

AUDIO TECH

OFFICE

FEMALE

TOILET

HYDROTHERAPY OFFICE

HAC

AUDIOLOGY

TOILET

EXAM RM

STORAGE

AUDIOLOGIST

EXAM RM

CORRIDOR

STAIR-2

MECH RM

AUDIOLOGISTAUDIOLOGIST

EXAM RM

STORAGE

WOUND NURSE

PHYSICAL THERAPY CLINIC

OFFICESTORAGEO T OFFICE

OFFICE/

RECEPTION

CHIEF O T

OFFICE

OFFICE OFFICE

TECHS OFFICE A D L

KITCHEN

TOILET

EXAM RMEXAM RMEXAM RMEXAM RM

EXAM RM

MINOR SURGY

OPHTHALMOLOGY

EXAM

OFFICE

TREATMENT

ROOM

EXAM RM

CONFERENCE

ROOM

STAIR

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

2 SOUTH 2 NORTH

B200

2 CENTER

B200E

2 SOUTH

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200ESOC-2

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

BUSINESS OCCUPANCY

FULLY SPRINKLERED

SECOND FLOOR

BUILDING 200E

N

200E

BUILDING 200E SECOND FLOOR

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

EL

EC

TR

IC

AL

R

M

OR

STORAGE

TOILET

SOILED

UTILITY

WOMENS

LOCKER RM

MENS

LOCKER

RM

TOILET

TOILET

NOURISHMENT

RM

LOCKER

TOILET

TOILET

EL

EC

TR

IC

AL

R

M

ELECTRICAL

CLEAN

UTILITY

CORRIDOR

CORRIDORCORRIDOR

CORRIDOR

MICU

SICU

CLASS RM

TEL CLOSET

TOILET

TOILET

CLEAN

LINEN

NEPHROLOGY

OFFICE

NEPHROLOGY

OFFICE

OFFICE (RENAL

CLINIC)

NEPHROLOGY

OFFICE

SURG

ADMIN

STAFF

SURGEON

STAFF

SURGEON

TREATMEN T

ROOM

STAFF

SURGEON

CHIEF

NEUROSURGERY

STAIR 2

STORAGE

STORAGE

ANEST OFFICE

SOILED

UTILITY

STORAGE

SURGICAL SVC

OR 5 OR 4

ELECTRICAL

CLOSET

HAC

STORAGE

OR 3

02/CO2

HAC

OR 2

EQUIP

OR 1

OFFICE

LOUNGE

DICTATING RM

M LOCKER RM

TOILET

F LOCKER RM

TOILET

PACU PRE OP AREA

TOILET

HAC

EXAM RM

NURSING

STATION

SUPPLY RM

ELECTRICAL RM

EXAM RM

CLEAN EQUIP

WATER

TANK

SOILED

EQUIP

SOILED

UTILITY

BREAK

CLEAN

UTILITY

WATER

TANK

HAC

DIALYSIS

ISOLATION

BED RM

LOCKER

RM

LOCKER RM

N MGR

OFFICE

CLEAN LINEN

RM

SOILED

UTILITY

CONSOLATION

RM

NURSING

STATIONSUPPLY

MED RM

BREAK

PROCEDURE RM1 BED RM1 BED RM1 BED RM

1 BED RM1 BED RM1 BED RM1 BED RM

HACSTAIR

1 BED RM

ANTE RM

1 BED RM

1 BED RM

ANTE

RM

1 BED RM

STORAGE

CORRIDOR

CORRIDOR

STAFF

SURGEON

OFFICE

CONFERENCE

ROOM

STAIR

SUITE

3,310SF

CORRIDOR

CORRIDOR

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

SZ-200E-3-SOUTH SZ-200E-3-CENTER SZ-200E-3-CENTER SZ-200E-3-NORTH

B 200

SZ-200E-3-CENTER

B 200E

SZ-200-3-CENTER

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200ESOC-3

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

HEALTHCARE OCCUPANCY

FULLY SPRINKLERED

THIRD FLOOR

BUILDING 200E

N

200E

BUILDING 200E THIRD FLOOR

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

~ROOF~

~ROOF~~ROOF~

C404

E400

C402 C401

C420

C401A

MECH RM

DAY ROOM

OFFICE SERVICE

LOBBY

ELECTRCIA;L

30 ft15 ft0 ft

0 ft 25 ft 50 ft 75 ft 100 ft

B 200

B 200E

SZ-200-4-CENTER

CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT: STATEMENT OF CONDITIONS

LIFE SAFETY ASSESSMENT

590 Means Street, Suite 200 Atlanta, Georgia 30318

(404) 214-9774

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE CONSULTANTS, L.L.C.

VISN 1 - New England Healthcare System

36C24121C0014

TOGUS VAMC

1 VA CENTER, AUGUSTA, ME 04330

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED

ON FIRE RATED DOORS.

2. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

3. INTERNAL SPRINKLER PIPING CONDITION AND

OBSTRUCTION INVESTIGATION.

FP&C Project Number 3259.00

200ESOC-4

08/18/2021 AF TK/KW

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM…