H312--Master Fire Alarm and Suppression Inspection Repair and Maintenance

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
36C26022Q0039
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Department of Veterans Affairs Jonathan M. Wainwright Memorial Vamc Walla Walla WA 99362

Notice details come from SAM.gov. Updated .

Notice text

1

The Walla Walla Veterans Administration Medical Center (WWVAMC) maintains 25 buildings and a water tower on its campus as well as oversight of 3 leased clinics at a distance from the campus. This contract seeks to consolidate fire system inspection, testing, repair/maintenance, and recordkeeping to maintain compliance with VA directives, National Fire Protection Association (NFPA) codes, State and Federal requirements, and the Joint Commission (TJC) standards. It includes fire alarm, fire sprinkler, fire damper and fire door components.

Place of Performance

All work under this contract is to be performed at the following locations:

Walla Walla VA Medical Center, 77 Wainwright Dr, Walla Walla, WA 99362

Lewiston CBOC, 1630 23rd Avenue, Lewiston, ID 83501

La Grande CBOC, 202 12th Street, La Grande, OR 97850

Yakima CBOC, 717 Fruitvale Blvd, Yakima, WA 98902

Period of Performance

The contract period base year will begin on date of award plus four (4) option years.

The VA CBOC lease locations are subject to change, cancellation, and or termination. At these locations the VA can cancel this contract with 30 days notice.

Scope

The Contractor shall furnish all labor, travel, equipment, supplies and materials required to perform a complete inspection, testing, maintenance and repair service of the systems in accordance with the frequency and procedures outlined in the most current edition of the Applicable publications below:

APPLICABLE PUBLICATIONS: The publications listed below form a part of this specification to the extent referenced. The publications are referred to by the basic designation only. The most current edition of these standards shall be applicable.

National Fire Protection Association (NFPA):

NFPA 13 Installation of Sprinkler Systems

NFPA 14 Installation of Standpipe and Hose Systems

NFPA 17A Wet Chemical Extinguishing System

NFPA 20 Installation of Centrifugal Fire Pumps

NFPA 25 Water Based Fire Protection Systems

NFPA 70 National Electric Code

NFPA 72 National Fire Alarm Code

NFPA 80 Fire Doors and Other Opening Protectives (Fire Dampers)

NFPA 90A Installation of Air Conditioning and Ventilation Systems

NFPA 96 Ventilation Control and Fire Protection of Commercial Cooking Operations

NFPA 101 Life Safety Code

NFPA 105 Smoke Doors and Other Opening Protectives (Smoke Dampers)

NFPA 291 Fire Hydrant Flow Testing and Marking

NFPA 2001 Clean Agent Fire Extinguishing Systems

Factory Mutual Approved Guide (FM)

Underwriters Laboratories, Inc. (UL)

Fire Protection Equipment Directory

The Joint Commission (TJC) Environment of Care Manual

The two primary fire systems are:

Fire Suppression System

Services to include but are not limited to the performance of inspection and preventive maintenance or repair services of all mechanical devices including valves, couplings, piping and connections, standpipes, backflow preventers, test headers and fire doors.

Preventive maintenance includes but is not limited to: lubricating control valve stems; adjusting packing glands on valves and pumps; bleeding moisture and condensation from air compressors, air lines, and dry pipe system auxiliary drains; and cleaning strainers. Frequency of maintenance is indicated in the appropriate chapter of NFPA 25.

Corrective maintenance includes, but is not limited to replacing corroded, or painted sprinklers; correcting obstructions to sprinkler spray patterns; repairing pipe leaks; replacing missing or loose pipe hangers; cleaning clogged fire pump impellers; and replacing valve seats and gaskets.

Emergency maintenance includes, but is not limited to, repairs due to piping failures caused by freezing or impact damage, and replacement of frozen or fused sprinklers. The contractor shall not be responsible for upgrades that are required by code due to a change in occupancy, relocation of partitions, or types of materials stored by the building occupants.

Notations:

Each bldg. has (1) PIV and FDC

Each separate system within each bldg. has: water flow alarm, 2-4 tamper switches, 2 pressure gauges

All dry systems have low air alarm

Inventory of buildings including square footage and type of Sprinkler System:

Bldg.

Floors (Sprinkled)

Exterior Gross Sq Ft

Dry/wet

WW-01

3

4,572

None

WW-31

1

4,288

4 Dry

WW-41

1

6,070

4 Dry

WW-48

3

3,356

3 Wet

WW-49

3

3,323

3 Wet

WW-63

1

2,184

4 Dry

WW-65

1

5,298

WW-66

2

8,760

4 Wet

WW-68

4

46,865

4 Wet & 4 Dry

WW-69

4

47,725

4 Wet & 4 Dry

WW-74

2

26,781

4 Wet & 4 Dry

WW-75

2

6,584

2 Wet & 4 Dry

WW-76

1

7,610

4 Wet

WW-77

1

4,398

4 Dry

WW-78

3

13,052

3 Wet, 2 Wet, 4 Dry, & 6 Dry

WW-80

2

20,743

4 Wet

WW-81

1

6,071

4 Wet

WW-82

3

8,647

4 Wet, 2 Wet, & 4 Dry

WW-86

5

50,416

6 Wet

WW-135

1

2,475

2 Wet

WW-140

2

21,333

4 Wet & 4 Dry + Electric Fire Pump

WW-143

2

71,160

6 Wet

WW-145

2

20,910

3 Wet

WW-148

100,000-gallon water tower

WW-T-1/T-2

2 Spaces 1 Valve

3,399

2x3 Dry

WW-T-7

2

6,288

4 Dry

Subtotal WW Campus

402,306 SF

Yakima CBOC

1

8,024

3 Dry

La Grande CBOC

1

8,682

Lewiston CBOC

2

6,620

Fire Alarm System

Initial Inspection and Test. The Contractor shall perform a full initial inspection and test of each device on the fire alarm system in accordance with the most recent edition of NFPA 72, National Fire Alarm Code.

Testing Frequencies from NFPA 72 shall be used.

Testing Methods from NFPA 72 shall be used.

Duties will be to inspect and test all associated with, to comply with annual and 4-year requirements.

Services include but are not limited to the performance inspection, testing, of a variety of fire alarm and notification systems, equipment and components such as manual alarm devices, smoke and heat detectors, remote and graphic annunciators, main fire alarm panel and components, speakers and horns and other audible and visual devices, voice alarm system, wiring circuits and junctions, all other alarm, detection and control and ancillary devices, door holders, fire door assemblies, elevator recalls, duct detectors, smoke and fire dampers, and emergency power operations.

Services to include preventive maintenance and repair of said items. Contractor must be able to make repairs to the proprietary fire alarm system at time of inspection including any programming changes.

The Contractor shall provide a telephone number where they can be reached for emergency calls 24-hours per day, seven days per week.

The Contractor shall have 2 hours to respond once notified of any issue(s) regarding the fire alarm system.

Files

File Type Posted
36C26022Q0039.docx DOCX document

Notice history

Notice Type Posted
H312--Master Fire Alarm and Suppression Inspection Repair and Maintenance Latest solicitation Solicitation
This notice Original Pre-Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors