H312--Fire Damper Testing and Inspections Services- Greater Los Angeles VA Healthcare System
Closed Solicitation Posted
- Solicitation number
- 36C26224Q0583
- Agency
-
Veterans Integrated Service Network 22
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 541350 Building Inspection Services
- PSC
- H312 Inspection- Fire Control Equipment
- Place of performance
- Department of Veterans Affairs Greater Los Angeles VA Healthcare System Los Angeles CA 90073, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation requests quotes for fire damper testing and inspection services at three Department of Veterans Affairs facilities in the Greater Los Angeles area. The scope requires inspection and testing of approximately 2,992 fire dampers across multiple buildings at the West Los Angeles VA Medical Center, Sepulveda VA Ambulatory Care Center, and Los Angeles VA Outpatient Clinic. Quotes are due by February 21, 2024 and must include pricing for inspections at each location, unknown dampers, access doors, and repairs. Award will be made based on a comparative evaluation of cost, schedule, technical capability, and past performance.
This opportunity is set aside 100% for Service-Disabled Veteran-Owned Small Businesses. The associated NAICS code is 541350 for fire protection services with a $11.5 million size standard. The period of performance is 180 days from award estimated between March 18, 2024 to September 30, 2024 across the three locations in Los Angeles: West Los Angeles VA Medical Center, Sepulveda VA Ambulatory Care Center, and Los Angeles VA Outpatient Clinic.
Notice text
2 versions
Update #2 · Latest ·
This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-02, effective 12/22/2023. This solicitation is set-aside for 100% Service-Disabled Veteran-Owned Small Business (SDVOSB). The associated North American Industrial Classification System (NAICS) code for this procurement is 541350, with a small business size standard of $11.5 Million. The FSC/PSC is H312. The award will be made to the quote most advantageous to the Government and best meets the requirement described in the statement of work. Price and Other Factors: See Attachment 2, FAR 52.212-2 Evaluation STATEMENT OF WORK (SOW) 1. Background Fire damper testing is a VA, The Joint Commission, and National Fire Protection Agency requirement in hospitals where patients are present overnight. The testing is required every 6 years. 2. Scope. The facility has an estimated 3000 fire dampers to test and inspect. See table below for breakdown of locations at West Los Angeles VA (WLA), Sepulveda VA and Los Angeles Outpatient Clinic (LAACC). Building Floor ECD ESD FD EFD PSD RD 213 3 0 0 18 0 0 0 Â 2 0 0 22 0 0 0 Â 1 0 0 22 0 1 0 Â Basement 0 0 43 0 1 1 Â Total: 0 0 105 0 2 1 214 4 0 0 3 0 0 0 Â 3 0 0 60 0 0 0 Â 2 0 0 58 0 0 0 Â 1 0 0 37 0 0 0 Â Total: 0 0 158 0 0 0 215 3 0 3 6 0 0 0 Â 2 0 3 4 0 0 0 Â 1 0 1 10 0 0 0 Â Basement 0 0 2 0 0 0 Â Total: 0 7 22 0 0 0 217 4 0 0 1 0 0 0 Â 3 0 0 46 0 0 0 Â 2 0 0 58 0 0 0 Â 1 0 0 59 0 0 0 Â Ground 0 0 31 0 0 0 Â Total: 0 0 195 0 0 0 257 Attic 0 0 12 0 0 0 Â 2 1 0 8 0 0 0 Â 1 27 0 23 0 0 0 Â Basement 0 0 94 0 0 0 Â Total: 28 0 137 0 0 0 500 Penthouse 0 0 6 0 0 0 Â 6 0 0 79 0 15 0 Â 5 0 23 108 0 3 1 Â 4 0 2 89 0 10 2 Â 3 0 0 81 0 4 0 Â 2 0 0 74 0 67 0 Â 1 3 6 381 0 229 2 Â Ground 0 7 231 0 104 4 Â Total: 3 38 1049 0 432 9 Â Â Â Â Â Â Â Â WLA Grand Total 31 45 1666 0 436 11 2189 LAACC- (LA VA OPC) 615 Sepulveda 188 3 locations grand total 2992 APW= Access Panel On Wall FD/ETL=Fire Damper Electric Thermo Link ATF= Access Thru Flex FNR= Failed Needs Repairs ATR= Access Thru Floor FRFD= Fire Rated Flange Door DID= Damper In Diffuser OK= Passed DTF= Down Thru Floor PCD= Pneumatic Combination Damper ECD= Electric Combination Damper PSD= Pneumatic Smoke Damper EFD= Electric Fire Damper R/D= Rolling Door ESD= Electric Smoke Damper RFL = Removed From List FD= Fire Damper O/D= Over Door VINE= Visually Identified Not Exercised L.L.= Lower Level I/S= Inside O/S= Outside 3. Specific Tasks. Contractor shall provide all labor, tools, equipment, parts, materials, dust control, travel and supervision required to perform all work at no additional costs to the government. Contractor shall inspect and test all dampers (listed in table of section 4 of this SOW), regardless of the type and/or style. Contractor shall replace all fusible links deemed in need of replacement from inspection. Contractor shall hand deliver old fusible links to Program Point of Contact (PPOC) or mail them to 11301 Wilshire Blvd Los Angeles CA 90073 Building 63 attention to: PPOC Name. Contractor shall document on VA provided statement of condition drawings the location and ID of each damper tested within this SOW. Contractor shall provide a complete report indicating the damper type, location, ID number assigned and if any repairs are required, Contractor shall provide a quote to the program point of contact for all unpriced CLINs (includes unknown dampers found, access doors, and repair costs in relation to findings from inspection) prior to work being conducted to first obtain Contracting Officer approval through a contract modification. Contractor shall provide damper inspection services as per National Fire Protection Agency 80 (with consideration given to applicable NFPA 101, NFPA 105, International Building Codes, and International Fire Codes). Dampers shall be inspected to the 2010 NFPA 80.19.3- 4 test standards as required. Acceptance testing of fire dampers shall be performed by a qualified person with knowledge and understanding of the operating components of the type of assembly being subject to testing and the system in which it is installed. Before testing, a visual inspection shall be performed to identify any damaged or missing parts that can create a hazard during testing or affect operation or resetting. Dampers that are part of the fire alarm network will not be tested solely as to the functionality of the fire alarm network. Inspection report shall be provided to the VA program point of contact in a .pdf document format and hard copy upon request. 3.1 Contractor shall inspect and document using approved NFPA 80 documentation for all fire dampers IAW the list of buildings in GLA (list of buildings and locations provided on tables under section 4- Scope). 3.1.1 Subtask 1. Provide a complete report of all dampers and report any repairs that need to be made, document locations on drawings provided. Inspection report shall include damper location, Inspection type, damper type, whether exercised or not, pass or fail, dampener access condition and damper motor condition, repairs required. Drawings will be provided by facility engineering department for each facility being inspected. 3.1.2 Subtask 2. An electronic tech from each facility will accompany the testing tech and provide support with the alarm system and access by carrying facility keys. The Program Point of Contact will meet with the contractor daily to provide progress updates. 4. Deliverables Provide the inventory and data electronically and in a bound report to Program Point of Contact. Indicate the location of all dampers on the statement of condition drawings, provided by VA to contractor, with ID numbers. 5. Performance Monitoring N/A 6. Security Requirements 6.1 Contractor shall obtain a visitor badge each day from the facility engineering point of contact. 6.2 Contractor will not have access to patient records, data, or VA computer systems. 7. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI) The government shall not furnish any equipment. 8. Risk Control Contractor must be responsible for containing dust while opening the ceiling in public areas, offices, or patient care areas. 9. Hours of Work Monday-Friday 7:00am 4:30pm PST; to exclude national holidays. National Holidays: New Year s Day January 01 Martin Luther King s Birthday Third Monday in January President s Day Third Monday in February Memorial Day Last Monday in May Juneteenth June 19 Independence Day July 04 Labor Day First Monday in September Columbus Day Second Monday in October Veterans Day November 11 Thanksgiving Day Fourth Thursday in November Christmas Day December 25 10. Place of Performance The work is performed at the Greater Los Angeles VA Healthcare System facilities: WLA, Sepulveda and LAACC in Los Angeles. See table for locations: West Los Angeles VA Medical Center 1131 Wilshire Blvd. Los Angeles, CA 90073 Los Angeles VA Outpatient Clinic 351 East Temple Street Los Angeles, CA 90012-3328 Sepulveda VA AMBULATORY Care Center 1611 Plummer Street Sepulveda, CA 91343 12. Period of Performance: 180 days from award; estimated 03/18/2024 09/30/2024. **PRICE/ COST SCHEDULE** ITEM # DESCRIPTION OF SUPPLIES/ SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 Fire Damper Testing and Inspection (Includes Fusible Link Replacement if needed)- West Los Angeles VA Medical Center Location. 2189 EA 0002 Fire Damper Testing and Inspection (Includes Fusible Link Replacement if needed)- Sepulveda VA Ambulatory Care Center Location. 615 EA 0003 Fire Damper Testing and Inspection (Includes Fusible Link Replacement if needed)- Los Angeles VA Outpatient Clinic Location 188 EA 0004 Fire Damper Testing and Inspection (Unknown Dampers Found)- West Los Angeles VA Medical Center Location. 1 EA $0 $0 0005 Fire Damper Testing and Inspection (Unknown Dampers Found)- Sepulveda VA Ambulatory Care Center Location. 1 EA $0 $0 0006 Fire Damper Testing and Inspection (Unknown Dampers Found)- Los Angeles VA Outpatient Clinic Location 1 EA $0 $0 0007 Access Doors Installation (If Needed)- All Locations 1 EA $0 $0 0008 Repairs, Costs in Relation to Findings from Inspections- All Locations 1 JB $0 $0 TOTAL **Please use the format above for pricing** The following solicitation provisions apply to this acquisition: FAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://www.sam.gov/portal in accordance with FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services. If paragraph (j) of the provision is applicable, a written submission is required. The following contract clauses apply to this acquisition: FAR 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services (Dec 2022) ADDENDUM to FAR 52.212-4, Contract Terms and Conditions-Commercial Products and Commercial Services applies to and is included with this acquisition. FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Products and Commercial Services (Mar 2023) The following subparagraphs of FAR 52.212-5 are applicable: (b)(5), (9), (12), (18), (26), (29), (30), (31), (33), (34), (35)(i), (36), (37), (39), (40), (48), (55), (62), (c), (1), (2), (4), (7), (8). VAAR 852.203-70 Commercial Advertising (May 2018). VAAR 852.219-73 VA Notice to Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses (JAN 2023) VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certification of Compliance for Services and Construction. (JAN 2023) (DEVIATION) VAAR 852.232-72, Electronic Submission of Payment Requests (NOV 2018). This is accomplished through the Tungsten Network located at: http://www.fsc.va.gov/einvoice.asp This is mandatory and the sole method for submitting invoices. Service Contract Act Wage Determination #: 2015-5613 Rev. 25 All quoters shall be submitted in accordance with FAR 52.212-1, Instructions to Offerors-Commercial Products and Commercial Services . (SEP 2023) All quotes shall be sent to the Network Contracting Office (NCO) 22 Contract Specialist, Jennell Christofaro at Jennell.christofaro@va.gov. Award will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of FAR 13. Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government. Decision factors to be considered are Cost, Schedule, Technical Capability, and Past Performance. This contract/purchase order will consist of a base period of performance: 03/18/2024 09/30/2024. The award will be made to the quote most advantageous to the Government and best meets the requirement described in the Statement of Work. Responses should contain your best terms, conditions. To facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows: "The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition." OR "The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:" Quoters shall list exception(s) and rationale for the exception(s), if any. All RFQ questions shall be received not later than February 15, 2024, 0900 MST at jennell.christofaro@va.gov only. Subject line shall include INQUIRY TO RFQ 36C26224Q0583 for consideration. All answers to inquiries received by due date and time will be addressed through an amendment. No further inquiries will be addressed after due date. Submission of your RFQ response offer shall be received not later than February 21, 2024, 1400 MST at jennell.christofaro@va.gov only. Subject line shall include RESPONSE TO RFQ 36C26224Q0583 for consideration. Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f). Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Point of Contact Contract Specialist Jennell Christofaro Jennell.christofaro@va.gov Attachment One: FAR 52.212-1 ADDENDUM Instructions to Offerors Attachment Two: FAR 52.212-2 Evaluation Attachment Three: VAAR 852.219-73 Notice of Total Set-Aside for Certified SDVOSB Attachment Four: VAR 852.219-75 SDVOSB Certification Attachment Five: Fire Damper Inspection Report Blank Template (End of Provision)
Update #1 ·
This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.
This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-02, effective 12/22/2023.
This solicitation is set-aside for 100% Service-Disabled Veteran-Owned Small Business (SDVOSB).
The associated North American Industrial Classification System (NAICS) code for this procurement is 541350, with a small business size standard of $11.5 Million.
The FSC/PSC is H312.
The award will be made to the quote most advantageous to the Government and best meets the requirement described in the statement of work.
Price and Other Factors: See Attachment 2, FAR 52.212-2 Evaluation
STATEMENT OF WORK (SOW)
1. Background
Fire damper testing is a VA, The Joint Commission, and National Fire Protection Agency requirement in hospitals where patients are present overnight. The testing is required every 6 years.
2. Scope.
The facility has an estimated 3000 fire dampers to test and inspect. See table below for breakdown of locations at West Los Angeles VA (WLA), Sepulveda VA and Los Angeles Outpatient Clinic (LAACC).
Building
Floor
ECD
ESD
FD
EFD
PSD
RD
213
3
0
0
18
0
0
0
Â
2
0
0
22
0
0
0
Â
1
0
0
22
0
1
0
Â
Basement
0
0
43
0
1
1
Â
Total:
0
0
105
0
2
1
214
4
0
0
3
0
0
0
Â
3
0
0
60
0
0
0
Â
2
0
0
58
0
0
0
Â
1
0
0
37
0
0
0
Â
Total:
0
0
158
0
0
0
215
3
0
3
6
0
0
0
Â
2
0
3
4
0
0
0
Â
1
0
1
10
0
0
0
Â
Basement
0
0
2
0
0
0
Â
Total:
0
7
22
0
0
0
217
4
0
0
1
0
0
0
Â
3
0
0
46
0
0
0
Â
2
0
0
58
0
0
0
Â
1
0
0
59
0
0
0
Â
Ground
0
0
31
0
0
0
Â
Total:
0
0
195
0
0
0
257
Attic
0
0
12
0
0
0
Â
2
1
0
8
0
0
0
Â
1
27
0
23
0
0
0
Â
Basement
0
0
94
0
0
0
Â
Total:
28
0
137
0
0
0
500
Penthouse
0
0
6
0
0
0
Â
6
0
0
79
0
15
0
Â
5
0
23
108
0
3
1
Â
4
0
2
89
0
10
2
Â
3
0
0
81
0
4
0
Â
2
0
0
74
0
67
0
Â
1
3
6
381
0
229
2
Â
Ground
0
7
231
0
104
4
Â
Total:
3
38
1049
0
432
9
Â
Â
Â
Â
Â
Â
Â
Â
WLA
Grand Total
31
45
1666
0
436
11
2189
LAACC- (LA VA OPC)
615
Sepulveda
188
3 locations grand total
2992
APW= Access Panel On Wall
FD/ETL=Fire Damper Electric Thermo Link
ATF= Access Thru Flex
FNR= Failed Needs Repairs
ATR= Access Thru Floor
FRFD= Fire Rated Flange Door
DID= Damper In Diffuser
OK= Passed
DTF= Down Thru Floor
PCD= Pneumatic Combination Damper
ECD= Electric Combination Damper
PSD= Pneumatic Smoke Damper
EFD= Electric Fire Damper
R/D= Rolling Door
ESD= Electric Smoke Damper
RFL = Removed From List
FD= Fire Damper
O/D= Over Door
VINE= Visually Identified Not Exercised
L.L.= Lower Level
I/S= Inside
O/S= Outside
3. Specific Tasks.
Contractor shall provide all labor, tools, equipment, parts, materials, dust control, travel and supervision required to perform all work at no additional costs to the government.
Contractor shall inspect and test all dampers (listed in table of section 4 of this SOW), regardless of the type and/or style.
Contractor shall replace all fusible links deemed in need of replacement from inspection.
Contractor shall hand deliver old fusible links to Program Point of Contact (PPOC) or mail them to 11301 Wilshire Blvd Los Angeles CA 90073 Building 63 attention to: PPOC Name.
Contractor shall document on VA provided statement of condition drawings the location and ID of each damper tested within this SOW.
Contractor shall provide a complete report indicating the damper type, location, ID number assigned and if any repairs are required,
Contractor shall provide a quote to the program point of contact for all unpriced CLINs (includes unknown dampers found, access doors, and repair costs in relation to findings from inspection) prior to work being conducted to first obtain Contracting Officer approval through a contract modification.
Contractor shall provide damper inspection services as per National Fire Protection Agency 80 (with consideration given to applicable NFPA 101, NFPA 105, International Building Codes, and International Fire Codes).
Dampers shall be inspected to the 2010 NFPA 80.19.3- 4 test standards as required. Acceptance testing of fire dampers shall be performed by a qualified person with knowledge and understanding of the operating components of the type of assembly being subject to testing and the system in which it is installed.
Before testing, a visual inspection shall be performed to identify any damaged or missing parts that can create a hazard during testing or affect operation or resetting.
Dampers that are part of the fire alarm network will not be tested solely as to the functionality of the fire alarm network.
Inspection report shall be provided to the VA program point of contact in a .pdf document format and hard copy upon request.
3.1 Contractor shall inspect and document using approved NFPA 80 documentation for all fire dampers IAW the list of buildings in GLA (list of buildings and locations provided on tables under section 4- Scope).
3.1.1 Subtask 1. Provide a complete report of all dampers and report any repairs that need to be made, document locations on drawings provided. Inspection report shall include damper location, Inspection type, damper type, whether exercised or not, pass or fail, dampener access condition and damper motor condition, repairs required. Drawings will be provided by facility engineering department for each facility being inspected.
3.1.2 Subtask 2. An electronic tech from each facility will accompany the testing tech and provide support with the alarm system and access by carrying facility keys. The Program Point of Contact will meet with the contractor daily to provide progress updates.
4. Deliverables
Provide the inventory and data electronically and in a bound report to Program Point of Contact. Indicate the location of all dampers on the statement of condition drawings, provided by VA to contractor, with ID numbers.
5. Performance Monitoring N/A
6. Security Requirements
6.1 Contractor shall obtain a visitor badge each day from the facility engineering point of contact.
6.2 Contractor will not have access to patient records, data, or VA computer systems.
7. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI)
The government shall not furnish any equipment.
8. Risk Control
Contractor must be responsible for containing dust while opening the ceiling in public areas, offices, or patient care areas.
9. Hours of Work
Monday-Friday 7:00am 4:30pm PST; to exclude national holidays.
National Holidays:
New Year s Day
January 01
Martin Luther King s Birthday
Third Monday in January
President s Day
Third Monday in February
Memorial Day
Last Monday in May
Juneteenth
June 19
Independence Day
July 04
Labor Day
First Monday in September
Columbus Day
Second Monday in October
Veterans Day
November 11
Thanksgiving Day
Fourth Thursday in November
Christmas Day
December 25
10. Place of Performance
The work is performed at the Greater Los Angeles VA Healthcare System facilities: WLA, Sepulveda and LAACC in Los Angeles.
See table for locations:
West Los Angeles VA Medical Center
1131 Wilshire Blvd.
Los Angeles, CA 90073
Los Angeles VA Outpatient Clinic
351 East Temple Street
Los Angeles, CA 90012-3328
Sepulveda VA AMBULATORY Care Center
1611 Plummer Street
Sepulveda, CA 91343
12. Period of Performance:
180 days from award; estimated 03/18/2024 09/30/2024.
**PRICE/ COST SCHEDULE**
ITEM #
DESCRIPTION OF SUPPLIES/ SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
0001
Fire Damper Testing and Inspection (Includes Fusible Link Replacement if needed)- West Los Angeles VA Medical Center Location.
2189
EA
0002
Fire Damper Testing and Inspection (Includes Fusible Link Replacement if needed)- Sepulveda VA Ambulatory Care Center Location.
615
EA
0003
Fire Damper Testing and Inspection (Includes Fusible Link Replacement if needed)- Los Angeles VA Outpatient Clinic Location
188
EA
0004
Fire Damper Testing and Inspection (Unknown Dampers Found)- West Los Angeles VA Medical Center Location.
1
EA
$0
$0
0005
Fire Damper Testing and Inspection (Unknown Dampers Found)- Sepulveda VA Ambulatory Care Center Location.
1
EA
$0
$0
0006
Fire Damper Testing and Inspection (Unknown Dampers Found)- Los Angeles VA Outpatient Clinic Location
1
EA
$0
$0
0007
Access Doors Installation (If Needed)- All Locations
1
EA
$0
$0
0008
Repairs, Costs in Relation to Findings from Inspections- All Locations
1
JB
$0
$0
TOTAL
**Please use the format above for pricing**
The following solicitation provisions apply to this acquisition:
FAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services
FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services
Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://www.sam.gov/portal in accordance with FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services. If paragraph (j) of the provision is applicable, a written submission is required.
The following contract clauses apply to this acquisition:
FAR 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services (Dec 2022)
ADDENDUM to FAR 52.212-4, Contract Terms and Conditions-Commercial Products and Commercial Services applies to and is included with this acquisition.
FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Products and Commercial Services (Mar 2023)
The following subparagraphs of FAR 52.212-5 are applicable: (b)(5), (9), (12), (18), (26), (29), (30), (31), (33), (34), (35)(i), (36), (37), (39), (40), (48), (55), (62), (c), (1), (2), (4), (7), (8).
VAAR 852.203-70 Commercial Advertising (May 2018).
VAAR 852.219-73 VA Notice to Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses (JAN 2023)
VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certification of Compliance for Services and Construction. (JAN 2023) (DEVIATION)
VAAR 852.232-72, Electronic Submission of Payment Requests (NOV 2018).
This is accomplished through the Tungsten Network located at: http://www.fsc.va.gov/einvoice.asp This is mandatory and the sole method for submitting invoices.
Service Contract Act Wage Determination #: 2015-5613 Rev. 25
All quoters shall be submitted in accordance with FAR 52.212-1, Instructions to Offerors-Commercial Products and Commercial Services . (SEP 2023)
All quotes shall be sent to the Network Contracting Office (NCO) 22 Contract Specialist, Jennell Christofaro at Jennell.christofaro@va.gov.
Award will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of FAR 13. Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government. Decision factors to be considered are Cost, Schedule, Technical Capability, and Past Performance. This contract/purchase order will consist of a base period of performance: 03/18/2024 09/30/2024.
The award will be made to the quote most advantageous to the Government and best meets the requirement described in the Statement of Work.
Responses should contain your best terms, conditions.
To facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:
"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition."
OR
"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:"
Quoters shall list exception(s) and rationale for the exception(s), if any.
All RFQ questions shall be received not later than February 15, 2024, 0900 MST at jennell.christofaro@va.gov only. Subject line shall include INQUIRY TO RFQ 36C26224Q0583 for consideration. All answers to inquiries received by due date and time will be addressed through an amendment. No further inquiries will be addressed after due date.
Submission of your RFQ response offer shall be received not later than February 21, 2024, 1400 MST at jennell.christofaro@va.gov only. Subject line shall include RESPONSE TO RFQ 36C26224Q0583 for consideration.
Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).
Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.
Point of Contact
Contract Specialist
Jennell Christofaro
Jennell.christofaro@va.gov
Attachment One: FAR 52.212-1 ADDENDUM Instructions to Offerors
Attachment Two: FAR 52.212-2 Evaluation
Attachment Three: VAAR 852.219-73 Notice of Total Set-Aside for Certified SDVOSB
Attachment Four: VAR 852.219-75 SDVOSB Certification
Attachment Five: Fire Damper Inspection Report Blank Template
(End of Provision)
Files
| File | Type | Posted |
|---|---|---|
| 36C26224Q0583 0001.docx | DOCX document | |
| Attch 5 - Fire Damper Report Blank Template.pdf | ||
| Attachment 1- 52.212-1 ADDENDUM Instructions to Offerors.pdf | ||
| Attachment 4 - VAAR 852.219-75 SDVOSB Certification.docx | DOCX document | |
| Attachment 3 - VAAR 852.219-73 Notice of Total SetAside for Certified SDVOSB.pdf | ||
| Attachment 2 - 52.212-2 Evaluation.pdf | ||
| 36C26224Q0583.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J012--FIRE DAMPER REPAIR SERVICES VA Central California Healthcare System | Veterans Integrated Service Network 21 | No set-aside | |
| CTX Life Safety Assessment and Fire Damper Inspection | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| 36C26127Q0086, Fire Extinguisher Inspection and Maintenance Services | Veterans Integrated Service Network 21 | Service-Disabled Veteran-Owned Small Business | |
| H212--Annual Test/Inspection of FireFly Device and Door Drop Cleveland VA Medical Center | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH | Veterans Integrated Service Network 15 | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity