This is a Sources Sought Notice for equipment testing and program monitoring services issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 23 (VA Black Hills Health Care System). The notice seeks market research information regarding services to support diagnostic radiological physics operations at three VA Medical Center locations: Fort Meade VA Medical Center (Fort Meade, South Dakota), Rapid City Community-Based Outpatient Clinic, and Hot Springs VA Medical Center. The primary service requirement involves a Board Certified diagnostic radiological physicist performing X-ray equipment testing, dose rate testing, performance monitoring, and leak testing of sealed radiation sources. Testing cycles occur annually in April, with additional leak testing in October and as-needed certification for newly acquired or repaired equipment. The equipment inventory includes radiographic-fluoroscopic imaging systems, mobile C-arms, mobile MRI units, CT scanners, dental X-ray systems, dose calibrators, thyroid uptake systems, densitometers, and various sealed radioactive sources (Cs-137, Ba-133, Co-57, Co-60). Services must comply with VHA National Health Physics Program guidelines and ACR Technical Standards.
Responses are due by December 3, 2026, at 12:00 PM Central Time to Alisha Milander at Alisha.Milander@va.gov. This is explicitly stated as market research only, with no solicitation for proposals, final pricing, or contract awards resulting from this notice. The NAICS code is 811210 (Electronic and Precision Equipment Repair and Maintenance) with a $34.0 million SBA small business size standard. Respondents must address five mandatory questions including socio-economic status and SAM Unique Entity ID; availability through existing government contracts; subcontracting plans; solution delivery lead time; and pricing for five line items covering April X-ray testing, April sealed source leak testing, October sealed source leak testing, as-needed follow-up testing, and travel expenses (up to $2,500 per instance for seven trips). The contract period runs from December 15, 2026, through December 14, 2027. The government will use responses to develop acquisition strategy regarding potential small business set-asides, including Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), and other socio-economic categories.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUBJECT*
Sources Sought - Equipment Testing and Program Monitoring Services of Radiology and Quality Programs - VA Black Hills Health Care System
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 55101 |
| SOLICITATION NUMBER* |
| 36C26327Q0137 |
| RESPONSE DATE/TIME/ZONE |
| 12-03-2026 12:00 PM CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 2 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| H266 |
| NAICS CODE* |
| 811210 |
| CONTRACTING OFFICE ADDRESS |
| DEPARTMENT OF VETERANS AFFAIRS |
NETWORK CONTRACTING OFFICE 23
316 ROBERT STREET N, SUITE 506
SAINT PAUL MN 55101
POINT OF CONTACT*
CONTRACTING OFFICER
ALISHA MILANDER
ALISHA.MILANDER@VA.GOV
PLACE OF PERFORMANCE
| ADDRESS |
| VA BLACK HILLS HEALTH CARE SYSTEM |
FORT MEADE VA MEDICAL CENTER
113 COMANCHE RD
FORT MEADE SD
| POSTAL CODE |
| 57741 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
| AGENCY CONTACT’S EMAIL ADDRESS |
| ALISHA.MILANDER@VA.GOV |
| EMAIL DESCRIPTION |
| CONTRACTING OFFICER |
DESCRIPTION
The VA Black Hills Health Care System – Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations – is conducting market research in accordance with RFO 17.204-1 Exercise of Options for Equipment Testing and Program Monitoring Services of the Radiology and Quality Programs as described in the Preliminary Statement of Work below.
This is a SOURCES SOUGHT NOTICE only looking for businesses to provide the services listed in the Preliminary Statement of Work below for market research purposes. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS OR FINAL PRICING AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs.
Responses to this notice will be treated only as information for the Government to consider as part of their market research efforts. The information provided will be used by the Government in developing its acquisition strategy regarding possible set aside for Service-Disabled Veteran-Owned, Veteran-Owned, and other socio-economic categories of small business. Interested parties are responsible for adequately marking proprietary, restricted or competition sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this notice and parties responding will not be entitled to payment for direct or indirect costs incurred in responding to this notice.
The North American Industry Classification System (NAICS) code for this requirement is 811210, Electronic and Precision Equipment Repair and Maintenance, with an SBA Small Business Size Standard of $34.0 Million.
If you are a vendor capable of providing the requested information and required services described below with competitive pricing, send your information with a description of proof of capability and answers to all questions to: Alisha.Milander@va.gov on or before Thursday, December 3, 2026 at 12:00 PM Central Time.
Please provide answers as appropriate to the following questions in the table below with your response to this Sources Sought. Failure to respond accurately to the following questions may affect the acquisition strategy. Failure to respond to the questions at all, or not respond to select individual questions, will result in your response being determined as non-responsive.
| 1. |
| Please provide all socio-economic categories of your firm (e.g., SDVOSB, VOSB, WOSB, Large Business, 8a, etc.) as well as your firm’s SAM Unique Entity ID number (replaces DUNS number) and Government Contract POC. |
| 2. |
| State whether the requested services may be ordered against a government contract awarded to your organization (e.g Federal Supply Schedule (FSS), General Services Administration (GSA), etc.). |
| 3. |
| State if subcontracting is contemplated for this requirement and what percentage of the work will be subcontracted and for what tasks. |
| 4. |
| Provide estimated lead time to deliver a fully functioning solution as described in the Preliminary Statement of Work below. |
| 5. |
| Complete the ITEM INFORMATION directly below this section for market research pricing for the services described in the Preliminary Statement of Work. |
ITEM INFORMATION
| ITEM NUMBER |
| DESCRIPTION OF SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1.00 |
| JB |
| $___________ |
| $___________ |
Perform certification via X-ray equipment testing, dose rate testing, and performance monitoring on radiographic fluoroscopy X-ray equipment for the Black Hills Health Care System during the month of April 2027 in accordance with the Statement of Work.
Contract Period: Base POP Begin: 12-15-2026 POP End: 12-14-2027 PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment
| 1.00 |
| JB |
| $___________ |
| $___________ |
Perform leak testing of sealed sources for the Black Hills Health Care System during the month of April 2027 in accordance with the Statement of Work.
POP Begin: 12-15-2026 POP End: 12-14-2027
| 1.00 |
| JB |
| $___________ |
| $___________ |
Perform leak testing of sealed sources for the Black Hills Health Care System during the month of October 2027 in accordance with the Statement of Work.
POP Begin: 12-15-2026 POP End: 12-14-2027
| 5.00 |
| JB |
| $___________ |
| $___________ |
Perform certification via X-ray equipment testing, dose rate testing, and performance monitoring as requested on all newly acquired radiographic fluoroscopy X-ray equipment for the Black Hills Health Care System throughout the period of performance and also perform follow-up testing on existing equipment on an as-needed basis when repairs are made or equipment is changed out requiring re-testing in accordance with the Statement of Work.
POP Begin: 12-15-2026 POP End: 12-14-2027
| 7.00 |
| EA |
| $___________ |
| $___________ |
Travel Expenses to perform services in accordance with the Statement of Work. Not to exceed $2,500 per instance.
POP Begin: 12-15-2026 POP End: 12-14-2027
*If applicable, RFO VAAR 852.219-75 VA Notice of Limitations on Subcontracting—Certificate of Compliance for Services and Construction, will apply to the potential solicitation if set-aside for Veteran Owned Small-Businesses or Service Disabled Veteran Owned Small-Businesses.*
*If applicable, RFO 52.219-14 Limitations on Subcontracting, will apply to the potential solicitation if set-aside for Small-Businesses.*
DISCLAIMER
This Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly. In accordance with RFO 15.101(c)(2), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought.
The deadline for this information is 12:00 PM Central Time on Thursday, December 3, 2026.
PRELIMINARY STATEMENT OF WORK
1. Introduction
The Black Hills Health Care System, Facilities Management Department requires a Board Certified diagnostic radiological physicist to perform equipment testing and program monitoring services of the radiology and quality programs at the Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations. The Board Certified diagnostic radiological physicist shall have the capability to support and service ALL listed radiographic/fluoroscopic x-ray equipment and also provide certification as requested of all newly acquired radiographic/fluoroscopic x-ray equipment throughout the period of performance of the contract and all exercised option years.
2. Requirements
a. General:
The Contractor shall provide a Board Certified diagnostic radiological physicist to perform equipment testing as specified in Paragraph 2.b. for all necessary equipment in April of each year (see Paragraph 2.d. Equipment Listing) and program monitoring services of the radiology and quality programs at the Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations. Services requested also include leak testing of sealed radiation sources as specified in Paragraph 2.c. in April and October of each year for specified equipment (see Paragraph 2.d. Equipment Listing). Additional services include follow-up testing and certification on existing equipment to be done on an as-needed basis as we make repairs or change out equipment that requires certification prior to use.
b. Radiographic Fluoroscopic X-ray Equipment Testing, Dose Rate Testing and Performance Monitoring (All April frequency cycle items in list below)
i. Testing and monitoring will conform to current VHA National Health Physics Program (NHPP) guidelines as noted in the references below.
ii. Testing will include but not be limited to:
· Measurement of radiation output parameters, including beam filtration
· Testing of automatic control systems such as automatic exposure controls of radiographic systems and automatic exposure rate controls of fluoroscopy systems
· Assessment of image quality
· Measurement of appropriate indices of patient doses or dose rates at clinical technique factors with comparison to national standards
· Measurement of minimum detectable activity of the Thyroid Uptake unit;
iii. Monitoring will include but not be limited to:
· A review of the quality control monitoring performed by technologists. The design will conform to the “ACR Technical Standard for Diagnostic Medical Physics Performance Monitoring of Radiologic and Fluoroscopic Equipment” and the “ACR Technical Standard for Diagnostic Medical Physics Performance Monitoring of Computed Tomography (CT) Equipment”, available from the American College of Radiology.
· Appropriate indices of doses to patients, as estimated by the diagnostic radiological physicist for the technique factors used at the facility, must be posted at or near the control console for each x-ray imaging device.
· For radiographic equipment, the entrance skin exposure, air kerma, or dose for a patient of typical size must be posted for common radiographic procedures.
· For fluoroscopic equipment, the entrance skin exposure rate, air kerma rate, or dose rate must be posted for a typical range of patient sizes for common modes of operation, including various image magnification factors, “boost mode,” if available, continuous fluoroscopy, and for pulsed fluoroscopy at the available pulse rates.
· For fluoroscopic equipment, the dose per image for each mode of image recording shall also be posted for a patient of typical thickness.
c. Leak Testing of Sealed Sources (All April/October Frequency Cycle Items in Paragraph 2.d. Equipment Listing):
i. Testing and recordkeeping requirements. Each licensee who uses a sealed source shall have the source tested for leakage periodically. The licensee shall keep a record of leak test results in units of micro curies and retain the record for inspection.
ii. Method of testing. The wipe of a sealed source must be performed using a leak test kit. The wipe sample must be taken from the nearest accessible point to the sealed source where contamination might accumulate. The wipe sample must be analyzed for radioactive contamination.
iii. Test frequency. (1) Each sealed source (except an energy compensation source (ECS)) must be tested at intervals listed (April/October). The Radiation Physicists will provide the wipe test kits, the analysis and the required report.
d. Equipment Listing:
Page 1 of
| Freq |
| Fac |
| Room # |
| Nomenclature |
| Manufacturer |
| Model |
| Serial Number |
| VA AEMS MERS ID |
| Apr |
| FM |
| 217A-145 |
| RADIOG-FLUORO IMAGING SYST (R/F) |
| GE Healthcare |
| OEC ELITE |
| FBXXTE02427 |
| 568 MX3387487 |
| Apr |
| FM |
| CS201I-113 |
| R/F UNITS: MOBILE, OEC ELITE CFD (CART) |
| GE Healthcare |
| OEC ELITE CFD |
| FBXXTE03024 |
| 568 MX3580117 |
| Apr |
| FM |
| S222-113 |
| R/F UNITS: MOBILE, OEC ELITE CFD (CART) |
| GE Healthcare |
| OEC ELITE CFD |
| FBXXTE03025 |
| 568 MX3580118 |
| Apr |
| FM |
| CS201I-113 |
| R/F UNITS: MOBILE, OEC ELITE CFD (C-ARM) |
| GE Healthcare |
| OEC ELITE CFD |
| X0034828007971 |
| 568 MX3580488 |
| Apr |
| FM |
| S222-113 |
| R/F UNITS: MOBILE, OEC ELITE CFD (C-ARM) |
| GE Healthcare |
| OEC ELITE CFD |
| X003482007868 |
| 568 MX3580489 |
| Apr |
| FM |
| 104-265 |
| MRI |
| Siemens |
| Magnetom Sola |
| 183215 |
| MX2583351 |
| Apr |
| FM |
| 148-113 |
| CT |
| Siemens |
| Definition AS |
| 96286 |
| MX665120 |
| Apr |
| FM |
| 154-113 |
| Spec-CT |
| GE Healthcare |
| Optima NM/CT640 |
| 640Y25559 |
| MX2037514 |
| Apr |
| FM |
| 143-113 |
| Radiographic Systems |
| Samsung Electronics |
| GC85A |
| 52RNM3RM900001J |
| MX2040652 |
| Apr |
| FM |
| 143-113 |
| Radiographic Systems |
| Samsung Electronics |
| GC85A |
| 55EVM3EM7000001W |
| MX2287241 |
| Apr |
| FM |
| 143-113 |
| R/F System |
| Siemens |
| Axiom Luminous agile |
| 61059 |
| EE43067 |
| Apr |
| FM |
| 143-113 |
| x-ray mobile |
| Samsung Electronics |
| GM85 |
| 55GFM31M400011K |
| MX1973107 |
| Apr |
| FM |
| 143-113 |
| x-ray mobile |
| Samsung Electronics |
| GM85 |
| 55GFM31M400012E |
| MX1973112 |
| Apr |
| FM |
| 313OP2-145 |
| xray Dental Intraoral |
| Sirona |
| Heliodent plus |
| 17647 |
| EE38836 |
| Apr |
| FM |
| 313OP3-145 |
| xray Dental Intraoral |
| Sirona |
| Heliodent plus |
| 31019665 |
| MX663076 |
| Apr |
| FM |
| 317-145 |
| xray handheld intraoral |
| Aseptico Inc |
| Nomad pro 2 |
| 1001091 |
| MX1882089 |
| Apr |
| FM |
| 318-145 |
| xray Panolypse |
| Planmeca |
| Promax S3 PAN |
| TPX356791 |
| EE38863 |
| Apr |
| FM |
| 155-113 |
| Dose Calibrator |
| Capintec Instruments |
| CRC-25R |
| 250014 |
| EE28935 |
| Apr |
| FM |
| 156-113 |
| Thyroid Uptake System |
| Biodex Medical Systems |
| HIT-W151 |
| KSA1590781 |
| MX419236 |
| Apr/Oct |
| FM |
| 155-113 |
| Cs137 .0001 curies |
| Capintec Instruments |
| CR-15E |
| S8117001-06 |
| none |
| Apr/Oct |
| FM |
| 155-113 |
| Ba133 .000231 curies |
| Capintec Instruments |
| CR-178E |
| S8107001-04 |
| none |
| Apr/Oct |
| FM |
| 155-113 |
| Co57 .99561 curies |
| RadQual |
| BM06E |
| BM06057E11278103 |
| none |
| Apr |
| FM |
| 127-113 |
| Densitometers: Bone: X-Ray |
| GE Healthcare |
| Lunar IDXA |
| 213130MA |
| MX3495174 |
| Apr |
| RCBOC |
| Mobile |
| Mobile MRI |
| Siemens |
| Magnetom AERA |
| 142349 |
| MX2067566 |
| Apr |
| RCBOC |
| 1910 |
| Radiographic System Digital |
| Phillips Corp |
| Digital Diagnost C90 |
| 22860092 |
| MX2991885 |
| Apr |
| HS |
| D020-12 |
| Mobile Scanning Systems: CT |
| Siemens |
| SOMATOM DEFINITION AS |
| 95402 |
| EE43219 |
| Apr |
| HS |
| B006-12 |
| R/F System |
| Siemens |
| Axiom Luminous agile |
| 61237 |
| MX423229 |
| Apr |
| HS |
| B002-12 |
| Radiology System |
| Samsung Electronics |
| GC85A |
| 52RNM3FM500001N |
| MX2047221 |
| Apr |
| HS |
| B002-12 |
| xray portable |
| Samsung Electronics |
| GM85 |
| 55GFM31M4000014D |
| MX1980227 |
| Apr |
| HS |
| D112A-12 |
| xray Panolypse |
| Planmeca |
| Promax S3 PAN |
| TPXV3062268 |
| MX1655374 |
| Apr |
| HS |
| D112B-12 |
| xray Dental Intraoral |
| dentsply Sirona |
| Heliodent plus |
| 63217 |
| MX1958839 |
| Apr |
| HS |
| D112C-12 |
| xray Dental Intraoral |
| dentsply Sirona |
| Heliodent plus |
| 63234 |
| MX1958841 |
| Apr |
| HS |
| D112E-12 |
| xray Dental Intraoral |
| dentsply Sirona |
| Heliodent plus |
| 63209 |
| MX1958843 |
| Apr/Oct |
| FM |
| 155--113 |
| CSs137 .000199 Curies |
| New England Nuclear |
| NES 356 |
| 3560180A-50 |
| None |
| Apr/Oct |
| FM |
| 155-113 |
| Co60 .00005 curies |
| New England Nuclear |
| NES 354 |
| 3540579A-49 |
| none |
| Apr/Oct |
| FM |
| 155-113 |
| Ba133 .00029 curies |
| New England Nuclear |
| NES 358 |
| 3580479A-02 |
| None |
| Apr/Oct |
| FM |
| 155-113 |
| Co57 |
| RadQual |
| BM06E-57 |
| BM6057E12083117 |
| None |
| Apr/Oct |
| FM |
| 155-113 |
| Co57 |
| RadQual |
| BM01-10 |
| BM011012088101 |
| None |
e. Training Requirements:
Appropriate vendor staff (as determined by the VA) performing the duties of the Statement of Work shall complete (print, review, and sign) the attached TMS 20939 “No Access” document. The Contractor shall send signed TMS 20939 documents to the Contracting Officer’s Representative Jonathan Maruszewski at jonathan.maruszewski@va.gov.
f. Security:
The Contractor shall adhere to only the following IT security sections contained in the IT Contract Security Clause below (VHA Handbook 6500.6):
1. GENERAL
g. Working Hours:
Anticipated hours of work will be Monday through Friday from 7:00 am – 4:00 pm. Additional hours must be coordinated through the COR/POC. Work will not be performed on weekends or federal holidays.
Observed Federal Holidays:
| New Year’s Day | Martin Luther King Birthday | ||
| Washington’s Birthday | Memorial Day | ||
| Juneteenth | Independence Day | ||
| Labor Day | Columbus Day | ||
| Veteran’s Day | Thanksgiving Day |
Christmas Day
h. References:
NHPP X-ray imaging guidance : http://nhpp.med.va.gov/NHPP_Diagnostic_Radiology_Info.asp
ARC Technical Standard for Diagnostic Medical Physics Performance Monitoring of Computed Tomography (CT) Equipment.
ARC Technical Standard for Diagnostic Medical Physics Performance Monitoring of Radiological and Fluoroscopic Equipment.
NCRP Report #102 “Medical X-ray, Electron Beam and Gamma-Ray Protection for Energies up to 50MeV (Equipment Design, Performance and Use)”
NCRP Report # 147 “Structural Shielding Design for Medical X-ray Imaging Facilities”
NCRP Report # 99 “Quality Assurance for Diagnostic Imaging Equipment”
NRC NUREG 1556, Volume 9 “Program-Specific Guidance About Medical Use Licenses.
Joint Commission Compliance Checklist: Diagnostic Imaging Standards: EC.02.01.01 - PI.02.01.01