H259-- Electrical System Maintenance, Inspection, and Testing
Closed Solicitation Posted
- Solicitation number
- 36C24826Q0054
- Agency
- Veterans Integrated Service Network 8 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Gainesville, Florida 32608, United States
- Points of contact
-
- Cesar O. Sanchez-Amaro cesar.sanchezamaro@va.gov (407) 403-2932
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8 is soliciting electrical maintenance, inspection, testing, and calibration services for the electrical power distribution systems at two facilities: Malcolm Randall Veterans Medical Center in Gainesville, Florida and Lake City Veterans Medical Center in Lake City, Florida. The solicitation requires contractors to provide comprehensive maintenance services for multiple electrical components including medium voltage circuit breakers, transformers, protective relays, low voltage power circuit breakers, switchgears, and transfer switches. Contractors must be certified by the National Electrical Testing Association (NETA), possess OSHA safety training, and comply with applicable electrical safety standards and codes. The contract will be awarded to the vendor offering the best value considering both technical capability and price as the primary evaluation criteria. The original proposal deadline was November 13, 2025, but has been extended to November 19, 2025, at 4:30 PM EST, with scheduled site visits on November 5, 2025, at the Gainesville facility and November 6, 2025, at the Lake City facility.
This solicitation (Number 36C24826Q0054) is exclusively set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), restricting competition to businesses meeting this certification requirement. The contract has an estimated total value of $19 million and carries a performance period from December 1, 2025, through June 2, 2026, representing a three-year electrical maintenance engagement. At the Gainesville facility, the scope includes maintenance for 34 medium voltage circuit breakers, 12 medium voltage transformers, 33 protective relays, 130 low voltage power circuit breakers, 20 switchgears/switchboards, and 48 transfer switches, with similar quantities required at the Lake City location. The government has provided one-line electrical drawings and combined testing reports for both facilities to support contractor proposal development. Performance will be conducted at both the Gainesville, Florida 32608 and Lake City, Florida locations.
Notice text
4 versions
Update #4 · Latest ·
The purpose of this amendment is to provide Testing Reports, One Line Drawings, and extend RFQ closing date. The North Florida/South Georgia Veteran Medical Center s in both Gainesville, Florida and Lake City, Florida has a requirement for maintenance, inspection, testing, and/or calibration of the Electrical Power Distribution System and all associated components.
Update #3 ·
The purpose of this amendment is to provide information for scheduled Site Visit and extend RFQ closing date.
The North Florida/South Georgia Veteran Medical Center s in both Gainesville, Florida and
Lake City, Florida has a requirement for maintenance, inspection, testing,
and/or calibration of the Electrical Power Distribution System and all associated
components.
Update #2 ·
The North Florida/South Georgia Veteran Medical Center s in both Gainesville, Florida and Lake City, Florida has a requirement for maintenance, inspection, testing, and/or calibration of the Electrical Power Distribution System and all associated components.
Update #1 ·
The North Florida/South Georgia Veteran Medical Center s in both Gainesville, Florida and
Lake City, Florida has a requirement for maintenance, inspection, testing,
and/or calibration of the Electrical Power Distribution System and all associated
components.
Attachments
| File | Type | Posted |
|---|---|---|
| S02. Lake City VA Combined Test Report Redacted.pdf | ||
| S02. Gainesville VA Combined Test Report_Redacted.pdf | ||
| 36C24826Q0054 0002.docx | DOCX document | |
| S02. Malcom Randall One Line Part 2.pdf | ||
| S02. Lake City One Line.pdf | ||
| S02. Malcom Randall One Line Part 1_1.pdf | ||
| 36C24826Q0054 0001.docx | DOCX document | |
| 36C24826Q0054.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| H259-- Electrical System Maintenance, Inspection, and Testing | Solicitation | |
| H259-- Electrical System Maintenance, Inspection, and Testing | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity