H212-- Fire Pump Test and Alarm support
Open Pre-Solicitation Posted
- Solicitation number
- 36C24227Q0094
- Agency
-
Veterans Integrated Service Network 2
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 561621 Security Systems Services (except Locksmiths)
- Place of performance
- Hudson Valley VA Medical Center aEUR" Castle Point Campus Wappingers Falls, New York 12590, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs' Hudson Valley VA Health Care System, under VISN 2 of the Veterans Health Administration, is conducting market research for annual fire pump inspection and performance testing at the Castle Point Campus of the Hudson Valley VA Medical Center in Wappingers Falls, New York. The Set Aside is Service-Disabled Veteran-Owned Small Business. This sources sought notice is not a solicitation. It is issued under FAR Part 10 to determine source availability and acquisition strategy. The posted due date is November 3, 2026, while the attached notice states responses are due November 2, 2026 at 10:00 AM Eastern Time.
The scope covers testing and inspection only. Repairs, replacement parts, and corrective maintenance resulting from testing are excluded. Required services include visual inspection of the pump, driver, controller, and associated equipment; verification of pump room conditions; inspection of suction and discharge piping, valves, gauges, and relief valves; verification of controller settings, alarms, and power supply; churn (no-flow) testing; and full-flow performance testing at 100% and 150% rated flow. Deliverables include annual test reports, flow test data sheets, pump performance curves, inspection documentation, and deficiency reports. Per the attached notice, contractors must show NFPA 25 testing experience and personnel holding NICET Level II or higher certification in water-based systems inspection and testing, along with appropriate licensing, insurance, calibrated testing equipment, and the ability to coordinate with facility personnel.
The notice lists NAICS 561621 as tentative and PSC H212. The source does not state a period of performance, quantity, or award value, and it names no incumbent. Industry engagement is limited to responding to the sources sought notice.
Notice text
SOURCES SOUGHT NOTICE
Annual NFPA 25 Fire Pump Inspection and Performance Testing
Hudson Valley VA Health Care System Castle Point Campus
Notice Type: Sources Sought / Market Research
This is not a solicitation. This notice is issued solely for conducting market research in accordance with FAR Part 10. The Government is seeking information from qualified vendors capable of providing annual fire pump inspection and performance testing services. Responses will be used to determine the availability of capable sources and the appropriate acquisition strategy.
Contracting Activity
Department of Veterans Affairs
Hudson Valley VA Health Care System
Place of Performance
Hudson Valley VA Medical Center Castle Point Campus
41 Castle Point Road
Wappingers Falls, NY 12590
Tentative NAICS and PSC
NAICS: 561621, Equipment and Materials Testing Fire Control Equipment
PSC: H212, Equipment and Materials Testing: Fire Control Equipment
Requirement Description
The Department of Veterans Affairs is conducting market research to identify qualified contractors capable of performing annual fire pump testing in accordance with the edition of NFPA 25 applicable to the facility and other applicable VA requirements. This requirement is for annual testing and inspection services only. Repairs, replacement parts, and corrective maintenance resulting from testing are not included in the contemplated contract.
The contractor shall provide qualified personnel, testing equipment, labor, supervision, and documentation necessary to perform annual fire pump inspection and performance testing. Services include, but are not limited to:
Visual inspection of fire pump, driver, controller, and associated equipment.
Verification of pump room conditions and compliance with NFPA 25 requirements.
Inspection of suction and discharge piping, valves, gauges, and relief valves.
Verification of controller settings, alarms, and power supply.
Churn (no-flow) testing.
Full-flow performance testing at 100% and 150% rated flow, where water supply permits.
Measurement and documentation of suction pressure, discharge pressure, flow, RPM, voltage, amperage, and other required performance data.
Verification of pump and controller operation.
Verification of supervisory and fire alarm signals affected by testing.
Documentation of deficiencies, limitations, and performance results.
Restoration of systems to normal operating condition following testing.
Deliverables
The contractor shall provide, at a minimum:
Annual fire pump performance test report.
Flow test data sheets and forms.
Pump performance curve comparison.
Inspection and test documentation.
Deficiency report identifying observed impairments and recommended corrective actions.
Documentation of any test limitations encountered during performance.
Contractor Qualification Requirements
Interested vendors should demonstrate:
Experience performing annual NFPA 25 fire pump testing.
Qualified personnel with documented training and experience.
NICET Level II or higher in Inspection and Testing of Water-Based Systems, or equivalent qualifications, if available.
Appropriate licensing, certifications, and insurance.
Availability of calibrated flow and pressure testing equipment or evidence of measurement accuracy.
Ability to coordinate with facility representatives and affected fire alarm monitoring/support personnel.
Response Requested
Interested firms shall submit the following information:
Company name.
UEI.
CAGE Code.
Business size status.
Socioeconomic status (e.g., SDVOSB, VOSB, WOSB, HUBZone, Small Business, Large Business).
Primary NAICS code.
Capability statement (maximum five pages).
Description of experience performing annual NFPA 25 fire pump testing.
At least two recent projects of similar scope and complexity.
Qualifications of personnel who would perform the testing.
Sample annual fire pump testing report.
Calibration documentation or description of testing equipment.
Confirmation of ability to complete the required services at the Castle Point Campus.
Identification of any subcontractors proposed for testing activities and their qualifications.
Special Notice to SDVOSBs and VOSBs
The Government is particularly interested in responses from:
Service-Disabled Veteran-Owned Small Businesses (SDVOSBs)
Veteran-Owned Small Businesses (VOSBs)
HUBZone Small Businesses
Women-Owned Small Businesses (WOSBs)
Small Businesses
Firms claiming SDVOSB or VOSB status should identify their certification status and applicable SBA certification information in their response.
Response Submission
Interested firms shall submit responses electronically no later than:
November 2, 2026, at 10:00 AM Eastern Time
Submit responses to:
Natalie Acevedo
Contract Specialist
Department of Veterans Affairs
Email: Natalie.Acevedo@va.gov
Emilyne Armendariz
Contract Specialist
Department of Veterans Affairs
Email: Emilyne.Armendariz@va.gov
Subject Line:
Sources Sought Response 36C24227Q0094 Annual NFPA 25 Fire Pump Inspection and Performance Testing
Disclaimer
This Sources Sought Notice is issued solely for market research purposes. This notice does not constitute a Request for Quotation (RFQ), Invitation for Bid (IFB), or Request for Proposal (RFP). The Government is not obligated to issue a solicitation or award a contract as a result of this notice. The Government will not reimburse respondents for any costs associated with preparing or submitting a response.
Files
| File | Type | Posted |
|---|---|---|
| 36C24227Q0094.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Building 13 Stair and Roof Replacement at Castle Point VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| J061--SOURCES SOUGHT NOTICE - Triennial Electrical Inspection Testing and Maintenance Services Requirement - Louis A Johnson VA Medical Center 36C24527Q0039 | Veterans Integrated Service Network 5 | No set-aside | |
| H945--Boiler Controls Inspection and Testing | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| J012--Fire Suppression Testing | Veterans Integrated Service Network 8 | Service-Disabled Veteran-Owned Small Business | |
| H399--36C242-27-AP-0524| 528-27-1-6893-0009 Elevator Inspections, Base (4) Canandaigua VA Medical Center (VAMC) & Bath VA Medical Center (VAMC) | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity