About this opportunity
The Department of Veterans Affairs (VA) is seeking a contractor to provide a complete chemical water treatment program to protect critical equipment and piping at three VA facilities in Texas - in Dallas, Garland, and Bonham. The contractor must have at least 10 years of experience providing similar services and assign a qualified water treatment specialist to the contract. The contractor must also utilize a state-certified laboratory to perform water analyses and provide recommendations. Key objectives include protecting equipment from corrosion and fouling while allowing optimal efficiency. Proposals are due by May 21, 2024.
This contract opportunity is set aside for service-disabled veteran-owned small businesses (SDVOSBs). The current incumbent contractor is Liberty Technical, and the contract term is a base year plus four option years from August 2024 to August 2029. The work will be performed at the specified VA facilities in Texas, and there are no details provided on the estimated award value or budget.
Notice text
2 versions
Update #2 · Latest ·
Intentionally Left Blank
Update #1 ·
Boiler/Chiller Plants Chemical Water Treatment Supplies and Services
WATER TREATMENT OBJECTIVES:
Contractor will provide a complete water treatment program that will protect critical equipment and piping from deterioration due to corrosion and fouling of waterside surfaces while allowing the equipment to operate at optimum efficiency. The water treatment supplier shall furnish effective products, quality service and good communications, all designed to meet the performance expectation outlined in this specification.
Places of Performance:
Dallas - Energy Center, Dallas VAMC, 4500 S. Lancaster Rd, Dallas, TX 75216
Garland - Boiler Chiller Plant Garland VAMC, 2301 Marie Curie Blvd, TX 75042
Bonham - Bonham VAMC Boiler Chiller Plant, 1209 E 9th St, Bonham, TX 75418
Period of Performance: Base plus 4 option years
Base Year: 08/21/2024 08/20/2025
Option Year 1: 08/21/2025 08/20/2026
Option Year 2: 08/21/2026 08/20/2027
Option Year 3: 08/21/2027 08/20/2028
Option Year 4: 08/21/2028 08/20/2029
CHEMICAL WATER TREATMENT CONTRACTOR QUALIFICATIONS:
1. The contractor shall have been in business at least 10 years providing chemical treatment of boiler/chiller plant and steam and chilled water distribution systems similar in design and annual steam production rates to that of the VA facility. Provide a list of at least five customers similar to VA who have utilized the services for boiler chemical treatment for at least three years.
2. One water treatment specialist who has a bachelor s degree in chemical engineering or the physical sciences from an accredited college or university shall be assigned to this contract. The water treatment specialist must have at least five years successful experience with boiler and chilled water treatment programs and shall furnish references from at least three customers who utilize boiler and chilled water treatment programs.
3. The water treatment specialist/subcontractor assigned to sites must be centrally located in the North Texas metroplex and 50 miles between all three sites to enable reasonable response times to request for site visits.
4. The contractor must operate (or continuously maintain a contract with) a state certified laboratory to perform complete scientific analyses of water chemistry, deposits, metallic materials affected by corrosion and provide recommendations for correction of problems related to the chemical and mechanical water treatment program.
See RFQ for more details.
Files
| File | Type | Posted |
|---|---|---|
| SF30 36C25724Q0525 0001.docx | DOCX document | |
| 36C25724Q0525 0001_1.docx | DOCX document | |
| Service Contract Act WD 2015-522_rv25_12-26-2023-Fannin County.pdf | ||
| Attachment B Engineering Standard ES 2019-001.pdf | ||
| RFQ 36C25724Q0525.docx | DOCX document | |
| Service Contract Act WD 2015-522_rv21_12-26-2023-Dallas County.pdf | ||
| Attachment A VHA Directive 1810_Jan 4 2023.pdf | ||
| 36C25724Q0525_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| H168--Boiler & Chiller Chemical Water Treatment Supplies and Services | Base + 4 | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J048--NEW - Energy Center Steam Header& Boilers valves, gaskets, and vent replacement | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| Testing & Inspecting, Preventative Maintenance, Corrective Repair, Emergency Repair, and Service Calls Amendment 0002 | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| H346--Legionella Water Testing | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| H246--Reverse Osmosis, Deionization Equipment and PE Water Softene 2026-2027 | Veterans Integrated Service Network 22 | No set-aside | |
| H146--water plant personnel - sheridan VA medical center | Veterans Integrated Service Network 19 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity