H159--NIHCS 3YR High Voltage Electrical Testing and Maintenance

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C25022Q0983
Agency
Veterans Integrated Service Network 10 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
238210 Electrical Contractors and Other Wiring Installation Contractors
PSC
H159 Quality Control- Electrical And Electronic Equipment Components
Place of performance
Northern Indiana Healthcare System Fort Wayne Vamc Fort Wayne IN 46805, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice seeks offers for three-year high voltage electrical testing and maintenance services for the Northern Indiana Healthcare System facilities in Fort Wayne and Marion, Indiana. The Department of Veterans Affairs Network Contracting Office 10 will award a firm fixed-price contract for clean testing, adjusting, calibrating and inspecting electrical distribution apparatus such as power transformers, switchgear, motor control centers and panel boards. Offerors should provide over-current testing for circuit breakers and adhere to IEEE megger voltage standards when testing without applying high pot voltage to feeder wires. The contractor will be responsible for reinstalling equipment in original condition and for any damage from negligence. Questions are due by September 1st and offers are due by September 6th, with site visits occurring on August 30th.

There is no set-aside designated for this procurement. The NAICS code is 238210 for quality control of electrical and electronic equipment components, with the PSC code H159 for quality control of electrical and electronic equipment components. The procurement is for triennial electrical testing and calibration services over a three year period at the Northern Indiana Healthcare System facilities in Fort Wayne and Marion, Indiana.

Notice text

Type: Pre-Solicitation Notice

Agency/Office: Department of Veterans Affairs, Network Contracting Office 10

Title: Three (3) Year High Voltage Testing and Calibration

Classification Code: H159 Quality Control- Electrical & Electronic Equipment Components

NAICS Code: 238210 Quality Control Electrical & Electronic Equipment

Components

Description:

The Department of Veterans Affairs, Network Contracting Office 10 is seeking to acquire Triennial (Every Three Years) Electrical Testing and Calibration electrical systems in accordance with the statement of work for the Northern Indiana Healthcare Systems, Ft. Wayne Campus located at 2121 Lake Ave. Ft. Wayne, IN 46805 and Marion Campus located at 1700 E. 38th St., Marion, IN 46953. Clean, test, adjust, calibrate, and inspect all the below mentioned electrical distribution apparatus. This shall include, but not be limited to, power transformers, switchgear, motor control centers, distribution centers, panel boards, air circuit breaker, vacuum circuit breakers, and loop switches listed in the statement of work. Over-current testing apparatus shall be limited to over-current relays for each 15 KV and 5 KV circuit breaker. Megger voltage shall not exceed IEEE standards. No high pot voltage to be applied to feeder wires. All equipment will be isolated from panel and feeders during testing for proper data reading. No variance. Contractor is responsible to reinstall equipment to original condition; verifying voltage, phasing and rotation. Any damage to equipment due to contractor neglect is the contractor s financial responsibility. The VA anticipates awarding a firm, fixed price contract for these services.

The Government anticipates release of the RFQ to be August 24, 2022 with a due date of September 6, 2022 at 9:00 am. Site Visit for each site will be held on August 30, 2022. Questions must be submitted in written form via e-mail to the Contracting Officer no later than 9:00 am EST September 1, 2022. (See Solicitation for Details on Site Visit)

The point of contact for this RFQ is Ms. Janel Tate, Contract Specialist, Network Contracting Office 10. Ms. Tate can be reached at Janel.Tate.Montgomery@va.gov.

Attachments

Files attached to this notice, newest first
File Type Posted
36C25022Q0983_1.docx DOCX document

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
H159--NIHCS 3YR High Voltage Electrical Testing and Maintenance Award Award Notice
H159--NIHCS 3YR High Voltage Electrical Testing and Maintenance Latest solicitation Solicitation
H159--NIHCS 3YR High Voltage Electrical Testing and Maintenance This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity