Grte headquarters chiller repair
Closed Special Notice Posted
- Solicitation number
- 140P1425Q0072
- Agency
-
Intermountain Region
National Park Service, Department of the Interior
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- J041 Maint/Repair/Rebuild Of Equipment- Refrigeration, Air Conditioning, And Air Circulating Equipment
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The National Park Service (NPS), through its Contracting Operations Central office, has issued a Sources Sought Notice for chiller repair and maintenance services at Grand Teton National Park's Headquarters Building. This Special Notice, published by the Department of the Interior, falls under NAICS Code 238220 for Plumbing, Heating, and Air Conditioning with a size standard of $19.0 million. The contracting opportunity involves comprehensive repair and maintenance work on the building's chiller system, including replacing a failed compressor and servicing five additional compressors and refrigerant systems. The work requires specialized HVAC expertise and must be performed during standard business hours from 7:00 am to 5:00 pm, Monday through Friday. This is strictly a market research initiative and not a formal solicitation for quotes.
The primary purpose of this Sources Sought Notice is to conduct market research to identify capable contractors and develop an advantageous acquisition strategy for the chiller repair project. Potential contractors must respond by July 11, 2024, at 12:00 pm Mountain Time, providing detailed information about their company capabilities, previous similar project experience, potential subcontracting requirements, and technical expertise. The project scope includes evacuating and leak testing six compressor/refrigerant loops, replacing Schrader valve stems, recharging systems with R-410A refrigerant, and performing heat exchanger maintenance including backflushing and cleaning. Contractors are required to demonstrate compliance with industry standards and regulations while providing comprehensive company information including SAM UEI numbers, business size classification, and commercial price lists. The NPS emphasizes that responses are voluntary, will become government property, and no reimbursement will be provided for preparation costs, with all information used solely for planning purposes within a 12-month timeframe.
Notice text
Grand Teton National Park's Headquarters Building Chiller Repairs and Maintenance.
United States Department of the Interior
NATIONAL PARK SERVICE
CONTRACTING OPERATIONS - CENTRAL
1849 C Street
NW Washington, DC 20240
SOURCES SOUGHT NOTICE
Project Title: Grand Teton National Park – Headquarters (HQ) Building Chillers Repair and Maintenance
Response Due Date & Time: 7/11/2024 at 12:00 pm (Noon) Mountain Time
NAICS Code: 238220 – Plumbing, Heating, and Air Conditioning
Size Standard: $19.0 Million
PSC Code: J041 – Maintenance/Rebuild/of Equipment – Air Refrigeration, Air Conditioning, and Air Circulating Equipment
Contracting POC & Title: Sally Leitch, Contracting Officer
Contracting POC Email: Sally_leitch@nps.gov
THIS IS S SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. ALL INFORMATION WILL BE USED FOR MARKET RESEARCH AND PLANNING PURPOSES ONLY
This is a request for information (RFI)/sources sought notice (SSN), issued in accordance with (IAW) FAR 15.201(e), to conduct market research. This RFI/SSN is issued solely for information and planning purposes. It does not constitute either a request for quotation (RFQ); nor is it a promise to issue an RFQ in the future. This RFI/SSN does not commit the Government to solicit or contract for any supply or service whatsoever. The NPS is not seeking quotes at this time and will not accept any unsolicited quotes.
IAW FAR 52.215-3 The Government does not intend to award a contract on the basis of this RFI/SSN or to otherwise pay for the information solicited. Any response to this notice shall be used for information only and does not constitute a quote or promise to acquire the products/services described herein.
The Government shall not pay for costs incurred while responding to this RFI/SSN. Vendors who do not respond to this RFI/SSN may still participate in any future RFQ. Information submitted in response to this RFI/SSN is strictly voluntary and becomes Government property. In addition, information received in response to this RFI/SSN will be utilized solely for market research and shall only be considered within 12 months of receipt.
This RFI/SSN is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or to award a contract. No reimbursement will be made for any costs associated with providing information in response to this posting or any follow-up information requests. This notice is a market research tool to help the NPS develop and decide on the most advantageous acquisition strategy.
The National Park Service (NPS), Contracting Operations (ConOps) Central, Northern Rockies Major Acquisition Buying Office (NR MABO) is seeking capable contractors to replace one and repair the HQ Building Chillers for Grand Teton National Park (GRTE).
Potential Project – Known Information:
The purpose of this project is to replace a failed compressor in the chiller as well as provide maintenance to the other five compressors/ refrigerant systems. The compressors are Copeland Scroll Mod: ZP385KCE-TWC-250, 200-230v 3ph
Each compressor (6) and refrigerant loop will be evacuated, pressurized with nitrogen and leak tested. All Schrader valves need to have the Schrader stem replaced. Repair any detected leaks in the refrigerant system. Each compressor/ refrigerant loop will need to have a vacuum pulled and recharged to factory pressure with 480 oz of R-410A refrigerant. Each compressor will need to be checked for proper operation, pressure, superheat and sub cool. Verify all compressors operate to manufacturers recommendations. Replace and install one failed compressor and filter dryer with new compressor and dryer of the same size and style. The chiller setup is comprised of 3 modules each with 2 compressors, 2 refrigerant loops, heat exchangers with the water loops. Each heat exchanger shall be back flushed as well as flushing out the main line basket strainer and any additional heat exchanger cleaning recommended by the manufacturer.
Required service times 7:00 am to 5:00 pm Monday through Friday.
Respond to this notice and provide, if interested and capable, the following information:
Project Related Questions:
1. Are there any special industry standards, licensing, laws, or regulations relating to this project?
2. How long would your firm require to perform services from start to finish?
3. Would your company need to subcontract any of the work on this project?
a. If so, please provide the percentage to be subcontracted out.
b. If so, please provide the name of the subcontractor.
4. Has your company provided same/similar services related to this project?
a. Provide previous similar project information, to include Place, Cost, POC and Email.
Company Related Questions:
1. Company Name
2. Company Address
3. Company POC
a. POC Title
b. POC Phone
c. POC email
4. Company SAM UEI number
5. Company Cage Code
6. Company Business Size
a. If your firm is a small business concern in any socio-economic category, will subcontracting requirements?
7. Does your company have a commercial price list that includes all the products/services as described herein?
a. If so, provide a copy with all applicable categories highlighted.
Files
| File | Type | Posted |
|---|---|---|
| A14_-_Sources_Sought_1.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Gwmp - arho bunker HVAC | Intermountain Region | Service-Disabled Veteran-Owned Small Business | |
| EROS Removal and replacement of chilled and conden | Office of Acquisitions and Grants | Total Small Business | |
| J041--Supply - Upgrade Chiller 3 Controls - NWI | Veterans Integrated Service Network 23 | No set-aside | |
| Troubleshoot & Repair of Portable Chillers Service Requirement | Air Education and Training Command | Total Small Business | |
| 500-Ton Trailer-Mounted Air-Cooled Chiller | Kennedy Space Center | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity