Opportunity facts

NAICS code
339113 Surgical Appliance and Supplies Manufacturing
PSC
6515 Medical And Surgical Instruments, Equipment, And Supplies
Place of performance
Bay Pines, Florida 33744, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs, Veterans Integrated Service Network 8 (Network Contracting Office 8), is conducting market research for four geriatric simulation mannequins and three decontamination-capable mannequins for C.W. Bill Young Veterans Medical Center in Bay Pines, Florida, with responses due by July 13, 2026 at 14:00. This Sources Sought notice is directed toward Service-Disabled Veteran-Owned Small Businesses (SDVOSB), Veteran-Owned Small Businesses (VOSB), and Small Businesses (SB), with potential SDVOSB set-aside determination; if insufficient SDVOSB responses are received, the requirement may be solicited as VOSB set-aside, SB set-aside, or unrestricted.

Geriatric simulation mannequins must be full-body, approximately five feet tall, weighing sixty to eighty pounds, constructed of non-toxic material simulating human tissue. Required capabilities include interchangeable pupils, articulated limbs, oral and nasal intubation, ventilation, CPR, airway management, catheterization, wound care, tracheostomy care, tube placement, ostomy care, IV administration, and monitoring of vital signs including heart, lung, and bowel sounds. The mannequins will support staff training on evacuation buses.

Decontamination mannequins must be full-body, approximately five feet tall, weighing sixty to eighty pounds, constructed of non-toxic, durable, non-electronic material capable of withstanding water saturation, cleaning solutions, and outdoor environments. Required features include an intubation head, IV arm with injection site, and moulage capability for hazmat training exercises.

Interested vendors should submit capability statements and supporting documentation via email to Michael A Shook, michael.shook@va.gov, explaining how proposed products meet salient characteristics.

Notice text

Good day, SDVOSB’s, VOSB’s & SB's     Sources Sought Pre-Solicitation

This Sources Sought is issued solely for informational and planning purposes only.  It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SB and large businesses. This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible.  If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB’s, the requirement may be solicited as a VOSB or a SB set aside, if no or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete.

        Please direct reply in the affirmative via email if you are interested and can provide the required product/service for this requirement. Please provide your capability statement, and any other supportive documentation.  I will accept responses to this Sources Sought until the 13th of July 2026 14:00, thanks.

General: C.W. Bill Young Veterans Affairs Medical Center10,000 Bay Pines Blvd, Bay Pines, Florida 33744, has a requirement for four (4) geriatric simulation mannequins and 3 decontamination capable mannequins for Bay Pines VA Medical Center.

Background: The BPVAHCS has requires 4 simulation mannequins to be used for staff training on the evacuation buses. Additionally, the BPVAHCS has a decontamination program that needs the decontamination mannequins for training and exercises.

Scope of Work: The mannequins provided must be equal to the salient characteristics listed below.  Explanation of how equal meets each salient characteristic must be included with quote.

3.1       Salient Characteristics (Geriatric Simulation Mannequin x 4)

  1. The mannequin should be a full body with the approximate height of an adult (approx. 5 ft) and weigh at least 60lbs. but no more than 80lbs.
  2. It should be made of material that will accurately simulate a human body and tissue, while still allowing for the required features listed below.
  3. The material shall be made of non-toxic material and safe to handle and touch
  4. Adult, elderly mannequin
  5. Interchangeable pupils to allow for normal, constricted or dilation
  6. Limbs must have a range of motion comparable to an average person
  7. Mannequin must be able to be turned, transferred, or position for patient care
  8. Must allow for oral and nasal intubation
  9. Must allow for ventilation
  10. Must allow for CPR compression
  11. Must allow airway management
  12. Must allow for urinary catheterization
  13. Must allow for wound care
  14. Must allow for tracheostomy care
  15. Must all for NG/PEG tube
  16. Must allow for ostomy care
  17. Must allow for IVs and injection sites
  18. Must allow for medication administration
  19. Must feature heart, lung, and bowel sounds
  20. Must allow for ECG placement
  21. Must allow for monitoring of blood pressure, temperature, SpO2, and ECG.
  22. Must allow for manual carotid pulse

3.2       Salient Characteristics (WMD/CBRNE/Decon Mannequin x 3)

  1. The mannequin should be a full body with the approximate height of an adult (approx. 5 ft) and weigh at least 60lbs. but no more than 80lbs.
  2. It should be made of material that will accurately simulate a human body for the purposes of decontamination.
  3. It should be made of material that can sustain being saturated in water and cleaning solutions for the purposes of decontamination
  4. It should be made of material that can be easily cleaned and dried after being processed through decontamination.
  5. It should be durable and be non-electronic construction, able to withstand wet and outdoor environments
  6. The material shall be made of non-toxic material and safe to handle and touch
  7. Full body mannequin designed for decontamination training and practice
  8. Intubation head allowing for airway management
  9. IV arm with injection site
  10. Designed to withstand decontamination practice and use in hazmat exercises
  11. Must allow for moulage

Attachments

Files attached to this notice, newest first
File Type Posted
SS- PRE-36C24826Q0892.pdf PDF
SS Pre-SOL 36C24826Q0806.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
6515--Geriatric & Decon Manikins Award Award Notice
Geriatric & Decon Manikins AMENDMENT 0002 Latest solicitation Solicitation
Geriatric & Decon Manikins This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity