The 42nd Contracting Squadron at Maxwell Air Force Base, Alabama issued a sole-source notice on August 31, 2026 with a September 4, 2026 response deadline, announcing its intent to award a contract to Sunbelt Fire, Inc. for procurement and installation of a Bauer Air Compressor Workstation at Gunter Fire Station. The government intends sole source award under RFO 5.101(a), but will consider competitive alternatives if other qualified vendors respond by the deadline.

The requirement replaces a 22-year-old Maco SCBA air compressor. The contractor must supply all labor, materials, tools, equipment, engineering support, and technical expertise to provide and install the Bauer Unicus 4S compressor workstation in accordance with the attached Statement of Requirements. The equipment includes a 6000 psi 13.0 scfm compressor with 10 HP motor, full gauge panel, emergency stop switch, UL-listed electrical assembly in NEMA 4 enclosure, Bauer PLC-based controller with 7-inch color HMI touch screen, P2 B-Securus purification system, automatic condensate drain, remote fill option with 100-foot hose reel, electronic carbon monoxide monitor with calibration kit, and sound attenuating enclosure. The compressor must be brand new; refurbished items are prohibited. Installation requires relocating the existing power supply disconnect panel and water supply shut-off valve. Delivery is to Building 834 at Maxwell/Gunter Annex. The contractor must provide original equipment manufacturer standard commercial warranties, all manufacturer documentation, written warranty procedures with technical support contact information, and training for fire department personnel.

Interested contractors must submit written responses by September 4, 2026 at 12:00 PM CST to A1C Jonathan Cheslo (jonathan.cheslo@us.af.mil, 334-953-8994) or Ms. Tatyana Webb (tatyana.webb@us.af.mil, 334-953-3538). Responses must include company information (name, CAGE code, business size, address, point of contact), detailed capabilities addressing the entire requirement with supporting documentation, and any additional information relevant to determining whether the requirement should be opened to competition. Respondents will not be reimbursed for response costs.

Notice text

2 versions

Update #2 · Latest ·

The 42nd Contracting Squadron at Maxwell AFB, AL hereby gives NOTICE OF INTENT TO AWARD A SOLE SOURCE to Sunbelt Fire, INC., 8050 McGowin Drive, Fairhope, AL 36532, to provide all labor, materials, tools, equipment, engineering support, and technical expertise required to safely and fully provide and install a Bauer Air Compressor Workstation. The Primary North American industry Classification System (NAICS) code is 333912 – Air and Gas Compressor Manufacturing.

Brief Description of Requirement: To replace and upgrade Gunter fire stations’ Maco SCBA air compressor (22 years old). Upgrading to a Bauer Workstation is a critical investment in ensuring the safety, efficiency, and operational readiness of a fire department. The primary function of the Bauer Workstation is to safely fill SCBAs with high-quality, breathable air, ensuring that firefighters have a reliable and clean air supply during dangerous operations. SCBAs are critical for protecting firefighters from inhaling toxic fumes, smoke, and harmful chemicals encountered in a fire. An outdated or unreliable air supply system can compromise the health and safety of personnel by causing delays in air refilling, contamination, or failure to meet the required air pressure levels, which could lead to life-threatening situations. Must be able to supply a Bauer SCBA Air Compressor in accordance with (IAW) the specifications laid out in the attached Statement of Requirements (SOR).

If interested, please respond to this notice following the attached instructions.  

Update #1 ·

The 42nd Contracting Squadron at Maxwell AFB, AL hereby gives NOTICE OF INTENT TO AWARD A SOLE SOURCE to Sunbelt Fire, INC., 8050 McGowin Drive, Fairhope, AL 36532, to provide all labor, materials, tools, equipment, engineering support, and technical expertise required to safely and fully provide and install a Bauer Air Compressor Workstation. The Primary North American industry Classification System (NAICS) code is 423850 – Service Establishment Equipment and Supplies Merchant Wholesalers.

Brief Description of Requirement: To replace and upgrade Gunter fire stations’ Maco SCBA air compressor (22 years old). Upgrading to a Bauer Workstation is a critical investment in ensuring the safety, efficiency, and operational readiness of a fire department. The primary function of the Bauer Workstation is to safely fill SCBAs with high-quality, breathable air, ensuring that firefighters have a reliable and clean air supply during dangerous operations. SCBAs are critical for protecting firefighters from inhaling toxic fumes, smoke, and harmful chemicals encountered in a fire. An outdated or unreliable air supply system can compromise the health and safety of personnel by causing delays in air refilling, contamination, or failure to meet the required air pressure levels, which could lead to life-threatening situations. Must be able to supply a Bauer SCBA Air Compressor in accordance with (IAW) the specifications laid out in the attached Statement of Requirements (SOR).

If interested, please respond to this notice following the attached instructions.  

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Breathing Air Systems Services for Fire Emergency Services at EAFB and P42 Edwards, California 93524, United States · NAICS 811310 Air Force Test Center No set-aside
Compressor unit Fort Bliss, Texas 79916, United States · NAICS 333912 ACC Redstone No set-aside
Air Compressor Relocation Washington, District of Columbia 20375, United States · NAICS 238210 Office of Naval Research No set-aside
Environmental Control System Orlando, Florida 32899, United States · NAICS 333413 Kennedy Space Center No set-aside
WPAFB 3rd Air Stream/ B18 Wright Patterson AFB, Ohio, United States · NAICS 238220 ENDIST Louisville No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity