Fire alarm panel
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- W911S225U1526
- Agency
- MICC Fort Drum Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 335311 Power, Distribution, and Specialty Transformer Manufacturing
- Place of performance
- Mcaapok 74501
- Points of contact
-
- Mike Fabry mike.j.fabry.civ@army.mil (918) 420-6580
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum is seeking to procure one MAAP-X Addressable Fire Alarm MNS Voice Evacuation Panel, specifically model part numbers 227-968-00 and 326-M01-20. The required system includes a master control unit with color touch screen, MNS message card with nine prerecorded messages, Analog Addressable Controller II backplane, various initiating device circuits, programmable relays, autosensing power supply, and dual rate battery charger meeting NFPA 72 and UL 864 requirements. The panel must feature fire and MNS operation capabilities for first responders, diagnostic functions, zone descriptions, and automatic transfer between AC primary and battery secondary power. An amendment was implemented to change the NAICS code from 922160 to 335311, reflecting the Power, Distribution, and Specialty Transformer Manufacturing category. The solicitation was posted on August 11, 2025, with responses due by August 19, 2025, providing contractors with an eight-day response window.
This opportunity is designated as a Total Small Business set-aside, restricting participation to qualified small business entities. No incumbent contractors or current service providers are identified in the solicitation notice. The procurement involves a quantity of one fire alarm panel system with no specified contract value or budget range disclosed in the available documentation. The place of performance is located on Unnamed Road in McAlester, Oklahoma 74501, indicating the equipment will be delivered and potentially installed at this location. The solicitation falls under PSC category 1265 for Fire Control Transmitting and Receiving Equipment, reflecting the specialized nature of the fire alarm and communication system being procured.
Notice text
2 versions
Update #2 · Latest ·
Implemented Amendment to change NAICS from 922160 to 335311 Model: MAAP-X Fire Alarm PanelPart Number: 227-968-00, 326-M01-20Qty. 1 ? MAAP-X Addressable Fire Alarm MNS Voice Evacuation Panel? Frequency of 138.95 (last five digits of part number)? Includes master control unit (MCU) with a color touch screen for fire and MNS Operation? An MNS message card with nine standard prerecorded messages (eight dedicated MNS, one dedicated fire)? An Analog Addressable Controller II (AAC II) backplane.? One ADCQ ? One SOC? Eight Class B or four Class A non-loop-powered Initiating Device Circuits (IDCs)? Eight Class B or four Class A regulated or synchronized programmable NACs ? Four Form C programmable relays? Autosensing power supply, 120/240 VAC 50/60 H? Dual rate 4A 24 VDC battery charger that meets the requirements of NFPA 72 and UL 864? Q24 VDC auxiliary power ? FSK interface for communication to D-21 through the standard integrated transceiver, or optional network or fiber module? Fire and MNS operation for first responders? Simple English messages identify alarm, trouble, and supervisory conditions? User-defined device and zone descriptions? Panel reset, alarm/trouble silence ? Displays zone input or addressable device programmable descriptions? LED status indicators for primary/secondary power, radio communication, general alarm, and trouble? Panel maintenance functions, such as: ? Zone and sensor device enable/disable? Walk test? Radio key-up test? Enhanced diagnostic information?identifying panel troubles and loop faults? Panel history? Standard card has eight default prerecorded MNS messages and one fire evacuation message for a total of nine prerecorded messages? User-defined messages available with a customer-option message card with eight user-defined prerecorded MNS messages and one user-defined prerecorded fire evacuation message? Transfer between AC primary power and battery secondary power is automatic
Update #1 ·
Model: MAAP-X Fire Alarm PanelPart Number: 227-968-00, 326-M01-20Qty. 1 ? MAAP-X Addressable Fire Alarm MNS Voice Evacuation Panel? Frequency of 138.95 (last five digits of part number)? Includes master control unit (MCU) with a color touch screen for fire and MNS Operation? An MNS message card with nine standard prerecorded messages (eight dedicated MNS, one dedicated fire)? An Analog Addressable Controller II (AAC II) backplane.? One ADCQ ? One SOC? Eight Class B or four Class A non-loop-powered Initiating Device Circuits (IDCs)? Eight Class B or four Class A regulated or synchronized programmable NACs ? Four Form C programmable relays? Autosensing power supply, 120/240 VAC 50/60 H? Dual rate 4A 24 VDC battery charger that meets the requirements of NFPA 72 and UL 864? Q24 VDC auxiliary power ? FSK interface for communication to D-21 through the standard integrated transceiver, or optional network or fiber module? Fire and MNS operation for first responders? Simple English messages identify alarm, trouble, and supervisory conditions? User-defined device and zone descriptions? Panel reset, alarm/trouble silence ? Displays zone input or addressable device programmable descriptions? LED status indicators for primary/secondary power, radio communication, general alarm, and trouble? Panel maintenance functions, such as: ? Zone and sensor device enable/disable? Walk test? Radio key-up test? Enhanced diagnostic information?identifying panel troubles and loop faults? Panel history? Standard card has eight default prerecorded MNS messages and one fire evacuation message for a total of nine prerecorded messages? User-defined messages available with a customer-option message card with eight user-defined prerecorded MNS messages and one user-defined prerecorded fire evacuation message? Transfer between AC primary power and battery secondary power is automatic
Notice history
| Notice | Type | Posted |
|---|---|---|
| Fire alarm panel | Award Notice | |
| Fire alarm panel | Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity