Emergency Repair Generator and High Voltage Line at FCI Phoenix- SOURCES SOUGHT NOTICE

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
15B60824PR000355
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Phoenix, Arizona 85086, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Federal Bureau of Prisons (FBOP) is seeking a contractor to perform emergency repair and maintenance work on a generator and high voltage lines at the Federal Correctional Institution (FCI) in Phoenix, Arizona. The project consists of removing, repairing, and re-installing an existing 3-phase, 2000 KW, 12,470V (capable of 13,800V) turbo-diesel generator, as well as providing trenching, installing conduit and high voltage lines, concreting, and filling in trenches. The applicable North American Industry Classification System (NAICS) code is 238210, with a corresponding small business size standard of $19 million. Interested small business contractors must be registered in the System for Award Management (SAM) and provide responses to the Sources Sought Questionnaire by September 20, 2024.

This contract opportunity is set aside for small businesses. The FBOP estimates the magnitude of the project to be between $1,000,000.00 and $5,000,000.00. The performance period is anticipated to be 365 calendar days. This is a Sources Sought Notice issued for market research purposes only, and is not a solicitation or invitation for offers. A synopsis of the proposed contract action will be posted at a later date, which will provide instructions for bidders to respond.

Notice text

THIS IS A SOURCES SOUGHT NOTICE. THIS NOTICE IS ISSUED FOR MARKET RESEARCH PURPOSES ONLY. THIS IS NOT A SOLICITATION OR INVITATION FOR OFFERORS TO SUBMIT BIDS.  A SYNOPSIS OF PROPOSED CONTRACT ACTION WILL BE POSTED AT A LATER DATE WHICH WILL PROVIDE INSTRUCTIONS FOR BIDDERS TO RESPOND TO THIS OPPORTUNITY.

PLEASE DO NOT RESPOND TO THIS NOTICE IF YOU ARE NOT SERIOUSLY INTERESTED AND IF YOU DO NOT PERFORM THIS REQUIREMENT. IT WILL DELAY THE POSTING OF THE SOLICITATION DUE TO FURTHER MARKET RESEARCH THAT WILL BE REQUIRED.

The Federal Bureau of Prisons (FBOP) anticipates issuance of a solicitation for the award of a firm-fixed-price construction contract for a project entitled Emergency Repair Generator and High Voltage Line, at the Federal Correctional Institution in Phoenix, Arizona.

FCI Phoenix is a federal correctional facility located at 37900 N. 45th Ave., Phoenix, Arizona, 85086.  The project consists of the contractor providing all necessary equipment, labor, and materials for:

1) Removal, repair and re-install of existing 3-phase, CAT SR4 HV rated 2000 KW, 12,470V (capable of 13,800V preliminary) turbo-diesel generator and final testing and activation of the new unit. 

2) Provide trenching for new high voltage lines that runs from the switchgear to wells, installing conduit and high voltage line, concreting the conduit, and filling in trenches.

See the Statement of Work/Specifications attachment included with the solicitation posting (to be issued at a later date as described herein) for the complete requirements of the work.  

Pursuant to Federal Acquisition Regulation (FAR) 36.204, the estimated magnitude of the project lies between $1,000,000.00 and $5,000,000.00. (NOTE: This range is one of 8 available ranges from FAR 36.204 and is not meant to imply that the project has necessarily been estimated/budgeted to the maximum of the selected range. It merely conveys that the estimate/budget lies somewhere within that range.)

The North American Industrial Classification System (NAICS) code applicable to this requirement is 238210 with a corresponding small business size standard of $19 million. To be considered an interested vendor, you must possess this NAICS code in your System for Award Management (SAM) registration.

Interested bidders must be registered in the SAM at www.sam.gov.

The FBOP is seeking small business contractors for this project. Your business size metrics information entered in your SAM registration must be less than or equal to the small business size standard specified above. Interested small business contractors are requested to respond to this notice by adding their names to the Interested Vendors List for this posting in SAM.gov (must be logged-in to your vendor account)

Files

File Type Posted
Sources Sought Questionnaire.pdf PDF

Notice history

Notice Type Posted
Emergency Repair Generator and High Voltage Line at FCI Phoenix Award Award Notice
Emergency Repair Generator and High Voltage Line at FCI Phoenix Latest solicitation Solicitation
Emergency Repair Generator and High Voltage Line at FCI Phoenix Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Install Generator- FCI Bastrop Bastrop, Texas 78602, United States · NAICS 238210 BOP Field Acquisition Office Total Small Business
FCI Three Rivers-Replace Generators, Transformers, and Electrical Infrastructure Three Rivers, Texas 78071, United States · NAICS 236220 Central Office Competitive 8(a)
FCI Marion - Emergency Repair Tornado Damage Marion, Illinois 62959, United States · NAICS 237130 BOP Field Acquisition Office Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity