Emergency Hangar HVAC Coil Repair

Awarded Limited / Sole Source Justification Posted

Solicitation number
W50S8S26PA002
Agency
Set-aside
No set-aside

Opportunity facts

Contract number
W50S8S26PA002
Place of performance
Swanton, Ohio 43558, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army National Guard's 180th Fighter Wing in Swanton, Ohio issued a sole source contract (W50S8S26PA002) on February 19, 2026 for emergency HVAC coil repair services at Building 101 under unusual and compelling urgency authority due to severe winter weather conditions anticipated in late January 2026 that threatened to cause further damage to the facility. The scope of work comprises four primary tasks: repair of two coils in the RTU West rooftop unit, installation of new heat trace on supply and return lines, performance of heat transfer calculations for raw water to glycol conversion, and mechanical room modifications including installation of a 70/30 glycol blend system with a 50-gallon makeup tank and bypass feeder system. The justification asserts that while multiple vendors possess the capability to complete this work, expedited sole source procurement was the most responsible approach to mitigate unacceptable risk to the building's heating system during critical weather periods. The contracting officer, MSgt Scott Hartzell, certified the anticipated cost as fair and reasonable on January 22, 2026, though the specific award amount and vendor identity remain redacted in the published documentation. This procurement was funded through Operations and Maintenance Air appropriations and was exempted from posting requirements due to the urgent nature of the requirement.

Notice text

Restore function to bldg. 101 Heating system by way of repair.

#1.  Repair the (2) coils in the RTU West

#2. Install new heat trace on the supply and return lines from the building loop up to the unit itself  

#3.  Have firm run calcs on heat transfer of raw water to glycol and will our coils and vav support the loss. 

#4. In the mechanical room cut off water feed from domestic and install and fill system with 70/30 blend of glycol.   50 Gallon make up tank for feeder and bypass system to manually feed.

Awarded contract W50S8S26PA002 to unknown vendor for unknown amount on 2026-02-19.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Replacement of 10 Ton HVAC Unit, Bldg. 11, PR ANG Carolina, Puerto Rico 00979, United States · NAICS 238220 Army National Guard Total Small Business
Repair Mechanical Systems IDIQ (FY 27-32) Wright Patterson Afb, OH 45433 United States 45433 · NAICS 238220 AFLCMC Wright Patterson AFB No set-aside
Replace HVAC Rooftop Units at Building 2275 March Air Reserve Base, California 92518, United States · NAICS 238220 Army National Guard No set-aside
Friant Dam HVAC Replacement - JOTFOC NAICS 238220 — No set-aside
USCG Station Lake Worth Inlet HVAC Diagnostic and Repairs Riviera Beach, Florida 33404, United States · NAICS 238220 — Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors