Elevator Refurbish and Maintenance, SLC ATCT, Salt Lake City, UT

Open Solicitation Posted

Solicitation number
697DCK-27-R-00021
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Salt Lake City, Utah 84116, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Federal Aviation Administration Southwestern Region seeks elevator refurbishment and one year of maintenance at the Salt Lake City Airport Air Traffic Control Tower under Screening Information Request 697DCK-27-R-00021, with offers due December 18, 2026. The procurement is a Total Small Business set-aside.

Place of performance is the tower at 1201 N. 4000 W., Salt Lake City, UT 84116. The contractor must modernize two elevators to the latest ASME A17.1 code: a gear traction elevator serving the 328-foot, 23-level tower and a hydraulic elevator serving the base building's first and second floors. Modernization covers controllers, hoist way switches, drive machines and sheaves, governors and safety systems, car structures, cabs, hoist way door panels, fixtures, signage, painting, and fire life safety integration. Work must begin within five calendar days of the Notice to Proceed and finish within 90 days. Post-modernization maintenance must achieve 99% or greater operational availability per quarter, allow no more than one unscheduled outage per quarter, and respond to service calls within one hour. The contractor also provides 24-hour emergency telephone monitoring during the warranty period. Required elements include FAA badging, OSHA compliance, qualified elevator mechanics and supervisors, original equipment manufacturer parts, and submittals (drawings, specifications, schedules, and quality control plans) before work begins. Normal hours are 6:00 a.m. to 2:30 p.m., Monday through Friday, with multiple shifts permitted to minimize downtime.

The solicitation has two line items: elevator upgrades and one year of maintenance following completion, with that period determined after upgrade completion. The contract is fixed-price with FOB Destination. The estimated magnitude of construction is $1.0 million to $5.0 million. The Elevator Repairer classification under Wage Determination 1986-0473, Revision 60, carries a $57.87 per hour base rate and $47.25 per hour in fringe benefits. Offerors must list at least three projects completed within the last five years of the same or similar size and scope. Prime and subcontractor experience are both accepted. The source names no incumbent and states no evaluation criteria.

Pre-proposal site visits are November 30 at 9:00 a.m. and 1:00 p.m., December 1 at 9:00 a.m. and 1:00 p.m., and December 2 at 9:00 a.m. Attendance is strongly encouraged, and interested firms must send visit dates, company name, and attendee details to Jordan Wyman at jordan.t.wyman@faa.gov or (206) 304-3683 at least one week prior. Questions go to Linda.Hennequant@faa.gov and must be received four days before the offer due date. Offers go to the same address under Section L, Provision L02. Every email must reference SIR 697DCK-27-R-00021 in the subject line or body, and telephone inquiries are not accepted. The procurement is conducted under the FAA Acquisition Management System rather than the FAR. The NAICS code is 238290, Other Building Equipment Contractors, and the PSC is Z2BA.

Notice text

The Federal Aviation Administration (FAA) is issuing Screening Information Request (SIR) Number 697DCK-27-R-00021, Elevator Refurbish and Maintenance, Air Traffic Control Tower (ATCT) at the Salt Lake City Airport (SLC), 1201 N. 4000 W, Salt Lake City, UT 84116 in accordance with the attached Request for Proposal (RFP).

The estimated magnitude of construction is between $1,000,000.00 and $5,000,000.00.

SITE VISIT

The FAA urges and expects offerors to inspect the site where the work will be performed. Pre-proposal Site Visits are scheduled for the following dates and times.

  • November 30 @ 9am and 1pm
  • December 1 @ 9am and 1pm
  • December 2 @ 9am

Please submit the below information to Jordan Wyman, (206)304-3683, jordan.t.wyman@faa.gov. at least one week prior:

  • Date and time of your visit
  • Company Name
  • All attendees’ Name, Email, Telephone

Site Visit Location: Air Traffic Control Tower Salt Lake City Airport, 1201 N. 4000 W., Salt Lake City, UT 84116

Information provided at this site visit, as well as answers to questions will not change/qualify the terms and conditions of the solicitation and specifications. Terms remain unchanged unless the solicitation is amended in writing. ATTENDANCE AT THE SITE VISIT IS STRONGLY ENCOURAGED.

QUESTIONS

All questions must be addressed to Linda.Hennequant@faa.gov in writing. Any questions regarding this RFP must be received four (4) days prior to the offers due date. All correspondences must contain the SIR # in the subject line. TELEPHONE INQUIRIES WILL NOT BE ACCEPTED. Emails with attachments that do not reference the SIR number in the subject line or the body of the message, will be disregarded to prevent the spread of computer viruses.

OFFER SUBMISSION: Send your offer to Linda.Hennequant@faa.gov. Reference Section L - Instructions, Conditions, and Notices to Bidders, Provision L02 REQUIRED DOCUMENTS. Emails with attachments that do not reference the SIR number in the subject line or the body of the message, will be disregarded to prevent the spread of computer viruses.

NOTICE

The FAA has been exempted from several Federal laws and regulations as part of the 1996 DOT Appropriations Act. Some of the exemptions include the Federal Acquisition Streamlining Act of 1994, the Small Business Act, the Competition in Contracting Act, and the Federal Acquisition Regulation (FAR). The FAA’s Acquisition Management System (AMS), which became effective on April 1, 1996, is utilized in place of the FAR.

This advertisement is not to be construed as a contract or a commitment of any kind.  The Government will not be liable for payment of any costs attributed to the preparation and submission of offers in response to this solicitation.

BASIS OF AWARD

Award will be based on the offering that is the lowest price technically acceptable offer (LPTA).  Prospective offerors are required to submit technical and business proposals as discussed in Section L of the RFP.

Thank you for your interest in our procurement opportunity.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
697DCK-27-R-00028: SEA Elevator Maintenance Services NAICS 238290 Southwestern Region No set-aside
FILA Elevator and vertical lift inspection service NAICS 238290 — Total Small Business
Elevator Repair and Maintenance Support Services Fort Huachuca, Arizona 85613, United States · NAICS 811310 ACC Aberdeen Proving Ground Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors