Electrical Outlets
Closed Pre-Solicitation Posted
- Solicitation number
- F3N0616023A006
- Agency
-
Air Forces Europe and Africa
Air Force, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Ramstein Air Base Rhineland-Palatinate 67661 Germany
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The United States Air Forces in Europe - Air Forces Africa is seeking contractors to install electrical outlets in two Large Area Maintenance Shelters (LAMS) at Ramstein Air Base in Germany to support cargo operations. The procurement requires the installation of 12 total 230-volt, 50Hz electrical outlets (6 per tent) with all necessary materials, labor, and equipment to complete the work in compliance with both the National Electrical Code (NEC/NFPA 70) and Verband der Elektrotechnik (VDE) standards for German electrical installations. Contractors must provide qualified personnel, all required tools and materials, and ensure safe and professional execution while coordinating with the designated government representative. This is a pre-solicitation notice posted on April 27, 2026, with a response deadline of May 9, 2026, and full and open competition is anticipated. No formal requests for quotation will be accepted at this time; interested parties should submit responses to indicate their capability to perform the work.
This procurement is not designated with any set-aside and is open to all responsible sources. The electrical system must include specific branded components including a Steidle outer distribution panel, two Spelsberg inner distribution panels, Hager B16A fuses, Weidmuller DIN rail terminal blocks, and Merten Aquastar 230V moisture-proof electrical outlets rated for outdoor or semi-covered operational environments. Work must be performed Monday through Friday between 08:00 and 16:00, excluding both U.S. Federal and German holidays, at the Large Area Maintenance Shelter adjacent to Building 3452 within a controlled and gated operational cargo facility. Upon completion, the contractor must verify functionality of all outlets, ensure proper grounding and circuit protection, and complete final inspection with the government representative. No specific budget range or award value has been disclosed in this pre-solicitation notice.
Notice text
***SEE ATTACHED PERFORMANCE WORK STATEMENT AND SALIENT CHARACTERISTICS***
The proposed contract action is anticipated to be full and open compitition it requires installation of electrical outlets inside the two Large Area Maintenance Shelter (LAMS) to support Cargo. Deployment Function (CDF) operations. Each tent requires six 230-volt outlets, for a total of twelve outlets. The requirements include all parts and labor necessary to complete the electrical outlets installation.
All electrical installations must comply with the National Electrical Code (NEC/NFPA 70) for U.S. requirements and Verband der Elektrotechnik (VDE) standards for German Electrical Installations, and all applicable civil engineering regulations.
IAW RFO 5.101(c)(2): Set asides are not applicable in Germany.
IAW RFO 5.101(c)(4):
(iii) Is not applicable to this requirement
(vi) All responsible sources are invited to submit a response to show interest which will be considered by the agency. Please note that this not a Request for Quotation but rather a pre-solicitation notice, and no quotes will be accepted in response at this time.
(viii) Installation Specifications for Electrical Outlets
- Quantity: 12 total outlets ( 6 per tent across two tents)
- Power rating: 230V, 50Hz (standard European system)
- Materials: Commercial grade receptacle, wiring, conduit, distribution board components, fasteners, and mounting hardware.
- Features: supports laptops, radios, fans, and administrative equipment.
- Qualification requirement: (NEC/NFPA 70) or (VDE) as mentioned above.
Files
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Sources Sought Replacement of Elevating Transfer Vehicles - Ramstein Air Base, Germany | AFLCMC Wright Patterson AFB | No set-aside | |
| Repair Electrical Systems | AFLCMC Wright Patterson AFB | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity