The Department of Energy Office of Science, through Brookhaven National Laboratory, is procuring a specialized "3 in 1" wide range vacuum sensor with integrated residual gas analyzer (RGA) system. The system must include a controller, power supply (90-264V AC), data cable for PC connectivity (D-SUB9/USB), DN40CF mounting flange, and operate within 10-45°C with bakeout capability up to 200°C without the controller. Technical requirements specify the ability to measure residual gas pressures from 1 to 300 amu over a pressure range of 1x10-11mbar to 1 bar, with sampling time under 500 ms, integrated leak detection capability better than 1x10-10 mbar*l/s, and software providing graphical interface for spectrum display. Vendors must include pricing, lead time, country of origin, and UEI in their quote packages. The solicitation was posted on September 4, 2025, with responses due by September 25, 2025.

This procurement opportunity carries no set-aside designation, making it open to all qualified contractors. No incumbent contractors or current service providers are identified in the solicitation documentation. The contract award value and budget range are not specified in the available materials. The procurement appears to be for a single unit based on the technical specifications provided, though exact quantities are not explicitly stated. Performance will take place at Brookhaven National Laboratory in Upton, New York 11973, with BNL covering shipping costs between the vendor and laboratory facility, and Charles Hetzel serving as the technical representative for this purchase order.

Notice text

"3 in 1" wide range vacuum sensor with integrated residual gas analyzer
Controller, power supply (power port, 90...264 V AC) with data cable to connect
with a PC (D-SUB9/USB)
Mounting flange: DN40CF (2.75" OD)
Operating temperature: 10...45°C
Bakeout temperature (without controller): 200°C

See STATEMENT OF WORK for more detailed information.

Please include pricing, lead time, country of origin and your UEI in the quote package

Files

File Type Posted
SOW.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
GA-vgms-33528 NAICS 334515 AFLCMC Wright Patterson AFB No set-aside
MCS2 Sensor Modules & Power Supplies, No Equivalents or Substitutions Upton, New York 11973, United States · NAICS 334516 Office of Science No set-aside
Optical Modulator (No Substitutions) Upton, New York 11973, United States · NAICS 334516 Office of Science No set-aside
Oxford PlasmaLab 100 tool PLC upgrade or its Equivalent Upton, New York 11973, United States · NAICS 811210 Office of Science No set-aside
PUR-2W-M12-BR; Pure Gas Dew Point Transmitters Orlando, Florida 32899, United States · NAICS 334516 Shared Services Center Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors