DBB Replace Chiller Construction in Building 6 at the Naval Support Activities (NSA), Philadelphia PA

Closed Pre-Solicitation Posted

Solicitation number
N4008524R2707
Agency
Responses due
Set-aside
Competitive 8(a)

Opportunity facts

Place of performance
Philadelphia, Pennsylvania 19111, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Navy Naval Facilities Engineering Command is seeking proposals for a Design-Bid-Build contract to remove and replace the existing chillers serving Building 6 at the Naval Support Activities (NSA) in Philadelphia, PA. The project involves the removal and replacement of the aging chillers with more efficient and reliable equipment, requiring minor piping modifications, new power and controls. Proposals are due by June 10, 2024, and the agency may have questions about submissions prior to that date.

This contract opportunity is set aside for competitive 8(a) businesses. The existing mechanical room contains multiple existing equipment and systems, and the new chillers must fit through the existing roll-up door opening. The new chillers must match the existing footprint and nozzle locations to minimize required modifications to the existing infrastructure. No incumbent or current contractor is specified, and the agency has not provided an estimated award value or budget range for this project.

Notice text

This project is a Design-Bid-Build contract for the construction to remove and replace the existing chillers currently serving Building 6. This project involves removable and replacement of the existing chillers. The work will require minor piping modification, provide new power and controls. The result of this construction work shall replace the aging chillers that requires constant maintenance to a more efficient and reliable chillers.

The existing Mechanical Room at Building 6 contains multiple piping, ductwork, electrical conduits, cable trays and major HVAC equipment. The existing chillers are located at the back of the Mechanical Room. The rollup door shall remain in place and existing opening to remain as is. The new chillers has to fit thru the existing roll up door opening and will require major rigging for the new chillers to fir thru various existing equipment within the Mechanical Room in order for it to be installed to its previous locations.

The new chillers is a direct fit which matches the existing foot print and nozzle locations with the existing chillers. The new chiller will not require major removal and replacements of the existing piping and valve systems. Due to its matching foot print, the new chillers can utilize the existing concrete pads. This will eliminate the need to jack hammer the existing concrete, removal of existing re-bars in order to provide the new equipment pads. Jack hammering will also create additional unwanted noise which will disturb administrative offices and cubicles located beside the Mechanical Room.

Similar open opportunities

Opportunity Agency Set-aside Responses due
RM16-1405 building 592 renovations Philadelphia Navy Yard, PA Philadelphia, Pennsylvania 19112, United States · NAICS 236220 Naval Facilities Engineering Command Competitive 8(a)
NSWCCD York Chill Pump Replacement Bethesda, Maryland 20817, United States · NAICS 333415 Naval Sea Systems Command No set-aside
Chiller NAICS 336413 Aviation No set-aside
CON | Z2DA | replace chiller 1 B104 | 580-24-111 | solicitation Houston, Texas 77030, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
C221--402-27-001 Repair Chiller 3 (AE) Veterans Affairs Medical Center Augusta ME 04330, United States · NAICS 541330 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors