Construct Fire Station Bay Storage Area, Malmstrom, MT
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- W912DW25R0ZX7
- Agency
- ENDIST Seattle US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Malmstrom Air Force Base, MT 59402
- Points of contact
-
- Cassandra Gonzalez cassandra.p.gonzalez@usace.army.mil (206) 316-3877
- Michael Saldaña michael.e.saldana@usace.army.mil (206) 764-3532
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers Seattle District is soliciting proposals for the construction of a Fire Station Bay Storage Area at Malmstrom Air Force Base, Montana. The project involves constructing an approximately 15,028 square foot facility designed to provide storage for Fire Emergency Services equipment and trailers, with an optional expansion of an additional 2,448 square feet. The facility must include a minimum of 8 trailer parking stalls with the option for 2 additional stalls, a dedicated foam storage room, and additional utility support spaces. The government intends for the facility to be constructed with the optional square footage increase and additional trailer parking stalls included. The solicitation deadline has been extended to June 12, 2025, at 10:00 AM Pacific Time, following Amendment R0006. A site visit was conducted on May 1, 2025, with representatives from multiple companies attending, including HD Inc, Copper Creek Construction, Gideon USA, STG Pacific, and AMS Dahlgren JV LLC.
This opportunity is designated as a Total Small Business set-aside under NAICS code 236220 for Commercial and Institutional Building Construction. The place of performance is Malmstrom Air Force Base in Montana, where the new storage facility will support fire emergency services operations. The project falls under PSC category Y1JZ for Construction of Miscellaneous Buildings, reflecting its specialized nature as a fire station support facility. The solicitation has undergone multiple amendments, with the most recent extending the proposal submission deadline by six days to accommodate bidder preparation time. While specific contract values are not disclosed in the available documentation, the scope indicates a substantial construction project given the facility's size and specialized requirements for emergency services equipment storage.
Notice text
6 versions
Update #6 · Latest ·
Please see Amendment R0007 Attachment.
Update #5 ·
Please see Amendment R0005 Attachment.
Update #4 ·
Please see Amendment R0004 Attachment.
Update #3 ·
The U.S. Army Corps of Engineers (USACE) Seattle District has a requirement FOR construction of a facility that will be an approximate 15,028 square foot facility that will provide storage for the Fire Emergency?s Services equipment and trailers with the option for an additional 2,448 square feet. The facility includes a minimum of 8 trailer parking stalls, with the option for an additional 2 trailer parking stalls, a dedicated foam storage room, and additional utility support spaces. The intent is for the facility to be constructed with the optional square footage increase and additional 2 trailer parking stalls. (Please see Amendment R0002)
Update #2 ·
The U.S. Army Corps of Engineers (USACE) Seattle District has a requirement FOR construction of a facility that will be an approximate 15,028 square foot facility that will provide storage for the Fire Emergency?s Services equipment and trailers with the option for an additional 2,448 square feet. The facility includes a minimum of 8 trailer parking stalls, with the option for an additional 2 trailer parking stalls, a dedicated foam storage room, and additional utility support spaces. The intent is for the facility to be constructed with the optional square footage increase and additional 2 trailer parking stalls.
Update #1 ·
The U.S. Army Corps of Engineers (USACE) Seattle District has a requirement FOR construction of a facility that will be an approximate 15,028 square foot facility that will provide storage for the Fire Emergency?s Services equipment and trailers with the option for an additional 2,448 square feet. The facility includes a minimum of 8 trailer parking stalls, with the option for an additional 2 trailer parking stalls, a dedicated foam storage room, and additional utility support spaces. The intent is for the facility to be constructed with the optional square footage increase and additional 2 trailer parking stalls.
Attachments
| File | Type | Posted |
|---|---|---|
| Amendment R0006 Final.pdf | ||
| R0001 Final.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Construct Fire Station Bay Storage Area, Malmstrom, MT | Award Notice | |
| Construct Fire Station Bay Storage Area, Malmstrom, MT | Solicitation | |
| FY25 MAFB Construct Fire Station Bay Area | Pre-Solicitation | |
| FY25 MAFB Construct Fire Station Bay Area | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity