C1DA--679-21-102 A/E-Correct Failing Sanitary Sewer, Water Main, and Fire Protection Deficiencies
Award Notice Posted
- Solicitation number
- 36C24722R0096
- Agency
-
Veterans Integrated Service Network 7
Veterans Health Administration, Department of Veterans Affairs
- Awarded
- to Ballard Clc, Inc.
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- Contract number
- 36C24723C0056 Federal contract award
- NAICS code
- 541330 Engineering Services
Notice details come from SAM.gov. Updated .
About this opportunity
The Award Notice from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 7 awarded a contract to BALLARD CLC, INC. to provide architectural and engineering design services. Under the $954,332 contract awarded on February 23, 2023, BALLARD CLC, INC. will develop plans and specifications to repair, replace, upgrade, or improve existing domestic water mains, sanitary sewers, storm drains, and fire protection piping at multiple campus facilities. The selected vendor will identify additional sanitary and storm drainage repairs through video inspection and expand the fire protection system, complying with all applicable codes and VA directives for healthcare facility design.
Notice text
Architect Engineer (A/E) team, including architects, engineers, surveyors, and professional consultants shall provide design services for the development of specifications and drawings to repair/replace, upgrade, or improve existing domestic water main, sanitary, storm, and fire piping and piping components throughout the campus, interior of buildings, and exterior of buildings. The A/E team will develop plans to replace existing domestic water piping loops and branch mains to each building. The A/E team is to scope and identify sanitary and storm water piping not corrected in previous projects that still needs to be repaired. Scoping shall be done with a video camera system and copies of the videos shall be provided to the facility. Additionally, A/E will develop plans to expand the fire protection system and add valves to the existing fire protection mains. All material is to be removed from the site and not be abandoned in ground. All drawings and specifications shall be designed to VHA directives and design manuals for healthcare facilities. Design shall meet most current building codes and regulations. This design shall follow all applicable Federal guidelines, all applicable law, and applicable codes and standards. This design will include but not be limited to the following disciplines: Civil, Electrical, Fire Protection, Mechanical, Plumbing, etc. Awarded contract 36C24723C0056 to BALLARD CLC, INC. for 954332.00000000 on 2023-02-23.
Files
| File | Type | Posted |
|---|---|---|
| 36C24723C0056_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Award Notice | |
| C1DZ--679-21-102 A/E-Correct Failing Sanitary Sewer, Water Main, and Fire Protection Deficiencies | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| C222--657A5-24-108, FCA Replace Medium Voltage Feeder 3 and Transformers l MC FY27 NRM VISN Base DE | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--598-22-115 Site Utility Infrastructure-NLR | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--CON-NRM-668-22-106 Correct Domestic Water System | Veterans Integrated Service Network 20 | No set-aside | |
| Y1DA--CON NRM 531-25-102 | Expand Emergency Room | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--Local | 460-26- 4-5074-0108 | 460-26-999 | Condenser Water Piping Modification | (VA-26-00077929) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities