C1DA-- 608-23-134 3rd Floor Gut Reno & 4th Floor East Wing
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C24123R0083
- Agency
-
Veterans Integrated Service Network 1
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 541310 Architectural Services
- Place of performance
- VA Manchester, NH 718 Smyth Road
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1 is seeking qualifications from small businesses to provide architectural and engineering design services for renovations to the third and fourth floors of Building 1 at the VA Manchester medical center in New Hampshire. The scope of work involves completely gutting and redesigning the third floor as well as partially gutting and redesigning the east wing of the fourth floor, including design of oncology, dentistry, physical therapy, occupational therapy, and other medical departments. Firms must have experience with similar medical renovation projects and licensed engineering staff, with submissions due by March 17, 2023 and evaluated based on experience, staff qualifications, proximity, and sustainability experience.
There is no set-aside designation for this procurement. The primary NAICS code is 541330 for architectural services and the period of performance is 100 calendar days upon notice to proceed. Interested firms must submit SF-330 qualifications statements along with proof of three relevant renovation projects and three medical department design projects completed in the past five years to be considered for the design work.
Notice text
DESCRIPTION
SOURCES SOUGHT:
INTRODUCTION & BACKGROUND
The objective of this scope of work is for architectural and engineering design services for
the entire third floor of building 1 and the east wing of the fourth floor of building 1.
The third and fourth floors have sustained significant damage due to a water line breakage
in 2022 making a renovation project necessary.
The third floor will be completely gutted from the concrete floor slab to the underside of
the concrete structure above and to the waterproofing on the exterior walls. All existing
architectural elements, floors, walls, doors, windows, casework, utilities, HVAC, plumbing,
sprinkler, fire alarm, HVAC controls, electrical, tel/data, and any system not specifically
mentioned here will be removed and new system designs will be required. The likely
program areas that will be designed for the third floor include: Oncology, Dentistry, Pain
Management, and other various flexible exam spaces. Each wing (north, east, west) will
have a mechanical room with air handlers and other infrastructure to support its
corresponding wing.
The fourth floor east wing will be mostly gutted with the exceptions of the doors, frames,
and wall studs (all drywall to be removed). Some existing electrical systems or devices
identified in the walls will be noted to remain. Everything else as noted for the third floor
will be removed and re-designed. The program area for this wing will not change, but a
similar concept to the design of the third floor for the infrastructure will be designed.
A design for how to address the exterior envelope will need to be developed for the third
and fourth floors including encapsulating the asbestos containing exterior wall
waterproofing, a new exterior wall insulating system, and new window systems and details.
Careful coordination will be required with the projects being designed on the second floor
SCOPE:
The scope of this project consists of Architectural and Engineer (A/E) services required to complete the project.
The period of performance for is 100 calendar days and shall begin upon issuance of the Notice to Proceed (NTP) by the Contracting Officer.
The VA will not be responsible for any costs incurred by interested parties in responding to this announcement.
This is a Request for Qualifications:
The purpose of this notice is to request SF-330 Qualification statements from qualified Small Businesses that have the experience directed at the requirements of the Statement of work.
The NAICS code is 541330 and the small business size standard is $25.5 million.
Firms must have valid registration in the System for Award Management (SAM). Visit: SAM.Gov to register in this database. SDVOSB/VOSB firms must be verified in VETCERT under NAICS 541330. Visit: https://veterans.certify.sba.gov/#home
RESPONSE:
Interested Small Business firms must provide their qualifications to the Contracting Specialist no later than2:00pm EST on 03/17/2023 via email to Carol.ahnee@va.gov
The following information is required as a valid response:
A positive statement of your intention to submit a proposal in response to a solicitation for this project and include your firm s Unique Entity (UE) ID Number, your address and Contact information.
Evidence of your experience in the selection criteria listed below.
SF-330 Architect- Engineer Qualifications completed for the intent of the project.
Evidence that your Small Business firm will perform more than 50% of the requirement with a qualified small business team.
The following selection criteria and adjectival ratings will be used to evaluate the submitted qualifications
Experience designing renovation projects in an occupied medical center (3 projects in last 5 years)
Experience designing Oncology, PT/OT, and Dental projects (3 projects in last 5 years)
Competency of staff in disciplines (Engineers w/ NH License)
Proximity to project location
Sustainability Experience (LEED Accredited professionals)
Failure to submit all information requested will result in a contractor not being considered as an interested Small Business concern.
EVALUATION FACTORS:
Adjectival
Description
Exceptional
A comprehensive and thorough presentation of extraordinary
merit with one or more significant strengths. Offeror s response is clearly superior. The response is innovative and exceeds requirements. No deficiency or significant weaknesses exists.
Good
Exceeds all the minimum requirements of the criteria; has an above average probability of success; contains no significant weaknesses and only minor, correctable weaknesses exist.
Acceptable
Meets all the minimum requirements of the criteria; has an average probability of success; no significant weaknesses and any deficiencies can be readily corrected.
Marginal
Fails to meet one or more of the minimum requirements of the criteria; low probability of success; major weaknesses and/or significant number of deficiencies exist.
Unacceptable
Fails to meet any of the minimum requirements of the criteria; very low probability of success.
Neutral
(Applies only to Past Performance)
Offeror s performance record, relevant past performance or information on past performance is not available
SELECTION PROCESS:
The A/E selection will be completed in two stages as follows: In Stage I, interested firms will submit SF-330 Qualification Statements of Capabilities. In Stage II, A/E team most qualified will be requested to submit a price proposal for negotiations in an issued Request for Proposal.
PROJECT INFORMATION: The scope of work for this project is attached.
Interested parties should submit their SF-30, proof of experience and all associated documents to Carol AhNee, contract specialist, via E-Mail at Carol.ahnee@va.gov. Responses are due by 03/17/2023 2:00 PM EASTERN TIME, NEW YORK, USA.
Files
| File | Type | Posted |
|---|---|---|
| 36C24123R0083.docx | DOCX document | |
| 608-23-134_AE SOW 3rd Floor Gut Reno and 4th Floor East Wing.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| C1DA-- 608-23-134 3rd Floor Gut Reno & 4th Floor East Wing | Award Notice | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| C1DA--AE Replace Roofing Cx - 539-25-101 | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--578-27-003 - Renovate A Section First Floor of Building 1 - Design FY27 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--Renovate Specialty Clinics on 2nd | Veterans Integrated Service Network 5 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--657-27-209JB Renovate Main Lobby, Bldgs 1 & 53 | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| C1AZ--657A4-26-125 Conduct Roof Deck Assessment Building 8 ME FY27 NRM | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity