36C24123R0083.docx

DOCX document 21 KB Posted

Attached to
C1DA-- 608-23-134 3rd Floor Gut Reno & 4th Floor East Wing
Solicitation number
36C24123R0083
Issued by

About this file

This sources sought notice is requesting qualifications from small businesses for architectural and engineering design services. Firms should have experience renovating occupied medical centers, including designing oncology, physical therapy, occupational therapy, and dental areas. The selected firm will completely renovate the third floor and part of the fourth floor at the VA Manchester facility in New Hampshire, gutting interior spaces and replacing all architectural elements, mechanical and electrical systems. The period of performance is 100 calendar days. Interested firms must submit SF-330 qualifications statements and supporting documentation to the Department of Veterans Affairs by March 17, 2023. Submissions will be evaluated based on experience with similar medical projects, staff qualifications, proximity to the project location, and sustainability experience.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
608-23-134 3rd Floor Gut Reno & 4th Floor East Wing

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
02301
SOLICITATION NUMBER*
36C24123R0083
RESPONSE DATE/TIME/ZONE
03-17-2023 2PM EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
C1DA
NAICS CODE*
541310
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

VA Boston Healthcare System Contracting Officer (90C) 940 Belmont Street Brockton MA 02301

POINT OF CONTACT*

Carol AhNee Carol.ahnee@va.gov carol.ahnee@va.gov 857-364-2263

PLACE OF PERFORMANCE

ADDRESS
VA Manchester, NH

718 Smyth Road

Manchester, NH 03104

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

DESCRIPTION

SOURCES SOUGHT:

INTRODUCTION & BACKGROUND

The objective of this scope of work is for architectural and engineering design services for the entire third floor of building 1 and the east wing of the fourth floor of building 1.

The third and fourth floors have sustained significant damage due to a water line breakage in 2022 making a renovation project necessary.

The third floor will be completely gutted from the concrete floor slab to the underside of the concrete structure above and to the waterproofing on the exterior walls. All existing architectural elements, floors, walls, doors, windows, casework, utilities, HVAC, plumbing, sprinkler, fire alarm, HVAC controls, electrical, tel/data, and any system not specifically mentioned here will be removed and new system designs will be required. The likely program areas that will be designed for the third floor include: Oncology, Dentistry, Pain Management, and other various flexible exam spaces. Each wing (north, east, west) will have a mechanical room with air handlers and other infrastructure to support its corresponding wing.

The fourth floor east wing will be mostly gutted with the exceptions of the doors, frames, and wall studs (all drywall to be removed). Some existing electrical systems or devices identified in the walls will be noted to remain. Everything else as noted for the third floor will be removed and re-designed. The program area for this wing will not change, but a similar concept to the design of the third floor for the infrastructure will be designed.

A design for how to address the exterior envelope will need to be developed for the third and fourth floors including encapsulating the asbestos containing exterior wall waterproofing, a new exterior wall insulating system, and new window systems and details.

Careful coordination will be required with the projects being designed on the second floor

1.0 SCOPE:

The scope of this project consists of Architectural and Engineer (A/E) services required to complete the project.

The period of performance for is 100 calendar days and shall begin upon issuance of the Notice to Proceed (NTP) by the Contracting Officer.

The VA will not be responsible for any costs incurred by interested parties in responding to this announcement.

This is a Request for Qualifications:

The purpose of this notice is to request SF-330 Qualification statements from qualified Small Businesses that have the experience directed at the requirements of the Statement of work.

The NAICS code is 541330 and the small business size standard is $25.5 million.

Firms must have valid registration in the System for Award Management (SAM). Visit: SAM.Gov to register in this database. SDVOSB/VOSB firms must be verified in VETCERT under NAICS 541330. Visit: https://veterans.certify.sba.gov/#home

RESPONSE:

Interested Small Business firms must provide their qualifications to the Contracting Specialist no later than2:00pm EST on 03/17/2023 via email to Carol.ahnee@va.gov

The following information is required as a valid response:

1. A positive statement of your intention to submit a proposal in response to a solicitation for this project and include your firm’s Unique Entity (UE) ID Number, your address and Contact information.

1. Evidence of your experience in the selection criteria listed below.

1. SF-330 Architect- Engineer Qualifications completed for the intent of the project.

1. Evidence that your Small Business firm will perform more than 50% of the requirement with a qualified small business team.

The following selection criteria and adjectival ratings will be used to evaluate the submitted qualifications

1. Experience designing renovation projects in an occupied medical center (3 projects in last 5 years)

2. Experience designing Oncology, PT/OT, and Dental projects (3 projects in last 5 years)

3. Competency of staff in disciplines (Engineers w/ NH License)

4. Proximity to project location

5. Sustainability Experience (LEED Accredited professionals)

Failure to submit all information requested will result in a contractor not being considered as an interested Small Business concern.

EVALUATION FACTORS:

Adjectival
Description
Exceptional
A comprehensive and thorough presentation of extraordinary

merit with one or more significant strengths. Offeror’s response is clearly superior. The response is innovative and exceeds requirements. No deficiency or significant weaknesses exists.

Good
Exceeds all the minimum requirements of the criteria; has an above average probability of success; contains no significant weaknesses and only minor, correctable weaknesses exist.
Acceptable
Meets all the minimum requirements of the criteria; has an average probability of success; no significant weaknesses and any deficiencies can be readily corrected.
Marginal
Fails to meet one or more of the minimum requirements of the criteria; low probability of success; major weaknesses and/or significant number of deficiencies exist.
Unacceptable
Fails to meet any of the minimum requirements of the criteria; very low probability of success.

Neutral (Applies only to Past Performance) Offeror’s performance record, relevant past performance or information on past performance is not available

SELECTION PROCESS:

The A/E selection will be completed in two stages as follows: In Stage I, interested firms will submit SF-330 Qualification Statements of Capabilities. In Stage II, A/E team most qualified will be requested to submit a price proposal for negotiations in an issued Request for Proposal.

PROJECT INFORMATION: The scope of work for this project is attached.

Interested parties should submit their SF-30, proof of experience and all associated documents to Carol AhNee, contract specialist, via E-Mail at Carol.ahnee@va.gov. Responses are due by 03/17/2023 2:00 PM EASTERN TIME, NEW YORK, USA.

See attached document: 608-23-134_AE SOW 3rd Floor Gut Reno and 4th Floor East Wing.

*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .