Boiler Inspections
Closed Solicitation Posted
- Solicitation number
- FA462625Q0016
- Agency
-
Global Strike Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541350 Building Inspection Services
- Place of performance
- Malmstrom AFB, Montana 59402, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Global Strike Command is seeking small businesses to provide comprehensive boiler inspection services at Malmstrom Air Force Base in Montana. The solicitation (FA462625Q0016) requires a contractor with NBIC (National Board Inspection Code) certification to conduct detailed inspections of watertube boilers manufactured by International Boiler Works. Specifically, the contract involves examining three high-temperature hot water boilers, with two boilers utilizing natural gas and coal as secondary fuel sources. Contractors must be prepared to review thickness testing data and previous inspection reports to establish baseline measurements for the comprehensive inspection process. The solicitation was posted on February 28, 2025, with proposal responses due by March 10, 2025, and interested firms should carefully review the attached Statement of Work and technical specifications.
The contract is set aside exclusively for small businesses within the Building Inspection Services (NAICS 541350) category, with performance located at Malmstrom Air Force Base in Montana. While specific award value details are not explicitly stated, the contract involves inspection services for multiple boiler units rated at 85 MMBTU/HR output. The primary point of contact for the project is Mr. Joseph Beard, who can be reached via DSN: 632-6431 or commercial phone: 406-731-6431. Contractors will need to comply with installation perimeter access control procedures and demonstrate expertise in mechanical infrastructure inspection. The contract appears focused on ensuring the continued operational integrity and safety of the base's critical boiler systems through rigorous professional inspection services.
Notice text
Inspections of Boiler related services at Malmstrom Air Force Base.
Files
| File | Type | Posted |
|---|---|---|
| Malmstrom Boiler-UPV Inspections.pdf | ||
| Unit 3 Data Sheet_0001.pdf | ||
| Unit 2 Data Sheet_0001.pdf | ||
| Q and A.docx | DOCX document | |
| Unit 1 Data Sheet_0001.pdf | ||
| Attch 3 Wage Determination.pdf | ||
| Attch 2 Installation Perimeter Access Control.pdf | ||
| Attch 1 Boiler Inspections SOW.pdf | ||
| Solicitation - FA462625Q0016.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Fuels Management Services at Malmstrom Air Force Base, MT and FE Warren Air Force Base, WY | Energy | Service-Disabled Veteran-Owned Small Business | |
| J041--Building 2 Steam Station Replacement | Veterans Integrated Service Network 1 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity