Backflow Device Testing - Base Plus 4 for Seattle and Magnolia VAMC
Closed Pre-Solicitation Posted
- Solicitation number
- 36C26025Q0028
- Agency
-
Veterans Integrated Service Network 20
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Seattle, Washington 98108, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 20 is seeking a contractor to perform comprehensive quarterly and annual inspections, testing, maintenance, and repair of up to 213 backflow prevention assemblies at the Seattle and Magnolia VA Medical Centers. The contractor must have certified inspectors, testers, and mechanics to carry out the work in compliance with applicable NFPA, ASME, ANSI, ASSE, ABPA, and UPC standards, as well as Washington state regulations. Responses to this pre-solicitation notice are due by October 22, 2024.
There is no set-aside designation for this opportunity. The contract will be awarded by the Department of Veterans Affairs, Veterans Integrated Service Network 20, but the notice does not identify any potential incumbent contractors. The notice also does not specify an estimated award value or budget range for the services. The work will involve inspecting, testing, repairing, and providing preventive maintenance for the backflow prevention assemblies at the two medical centers.
Notice text
The contractor shall perform the following specific tasks for the Seattle and Magnolia VAMC:
•Conduct comprehensive quarterly and annual inspections of all backflow preventionassemblies.
•Certify each backflow prevention assembly in accordance with the latest publishedstandards.
•Provide documentation and maintain certification records in compliance with theAmerican Backflow Preventer Association.
•Maintain, clean, and service backflow prevention assemblies as needed.
•Ensure all inspectors have received certification equivalent to the field test procedures inthe Manual of Cross-Connection Control, Tenth Edition.
•Submit proof of required licenses and personnel qualifications to the Contracting Officerprior to contract award.
•Inspect, test, repair, and provide preventive maintenance for up to 213 backflowprevention assemblies.
•Perform all work in compliance with NFPA 13, 17, NFPA 25, ASME, ANSI, ASSE,ABPA, UPC, and other applicable Federal Regulations.
•Provide inspection, testing, maintenance, and repair services by master plumbers,certified inspectors, testers, and mechanics qualified for backflow prevention assemblywork.
•Submit all required documentation and maintain necessary licenses and personnelqualifications in compliance with Washington State regulations.
Files
| File | Type | Posted |
|---|---|---|
| S02 36C26025Q0028.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA--CON-NRM-668-22-106 Correct Domestic Water System | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| J012-- Fire Alarm Suppression Maintenance & Repair Services | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| 648-22-104 Correct HVAC Deficiencies (P&V) | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| Repair Sanitary Waste Piping at the Mann-Grandstaff VA Medical Center | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| J065--ConMed AirSeals service | Veterans Integrated Service Network 20 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity