B207 Chiller Combo

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
B207Chiller
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Warner Robins, Georgia 31098, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Air Force Sustainment Center at Robins Air Force Base seeks a Carrier-brand 15-ton air-cooled chiller unit for Building 207, with quotes due July 30 at 12:00 PM Eastern. This is a Total Small Business set-aside under Simplified Acquisition Procedures for commercial items.

Place of performance is Warner Robins, Georgia. The chiller must operate on 460 volts, 3-phase, 60 Hz power and include a 5-year warranty on parts, start-up service, brazed plate heat exchanger with evaporator heater, standard SCCR, coil face shipping protection, single point no disconnect, digital compressor, standard sound rating, microchannel heat exchanger, BACnet IP connectivity, Greenspeed Intelligence variable condenser fans, and PIC6 controls. Delivery is required within two to four weeks of award, FOB Destination to Building 1555, with the unit to be transferred to Building 207 by the contractor. The contractor is responsible for unloading at Building 1555 and delivering to Building 207; the Government or its installation contractor will complete all mechanical, electrical, piping, and controls connections. Contractor start-up is limited to equipment start-up and operational verification after Government installation is complete. All contractor personnel must possess valid state-issued driver's licenses, pass background checks for base entry, and comply with Robins AFB security requirements and OPSEC protocols. Work hours are Monday through Friday, 0800–1600 hours, with all federal holidays recognized. Quotes must include cost breakdown, unit price, total price, payment terms, prompt payment discount, DUNS number, and cage code. NAICS is 333415; PSC is 4130. Small business size standard is 1,250 employees. Government points of contact are Roy Bowden (primary, 478-327-8969) and Gregory Wilson (alternate, 478-327-5372). Questions and answers posted July 29 clarified delivery requirements and contractor responsibilities.

Notice text

2 versions

Update #2 · Latest ·

See updated PDF documentation as of 14Jul26

This is a Brand Name Carrier unit, not equal to with salient characteristics, must be a Carrier Brand meeting the requirements  

Update #1 ·

See attachments 

Files

Notice history

Notice Type Posted
B207 Chiller Combo Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Chiller NAICS 336413 Aviation No set-aside
500-Ton Trailer-Mounted Air-Cooled Chiller Orlando, Florida 32899, United States · NAICS 333415 Kennedy Space Center No set-aside
Chiller NAICS 333415 Land and Maritime No set-aside
Chiller assy, aircra NAICS 336413 Aviation No set-aside
Troubleshoot & Repair of Portable Chillers Service Requirement Jbsa Lackland, Texas 78236, United States · NAICS 238220 Air Education and Training Command Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity