B207 Chiller Combo
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- B207Chiller
- Agency
-
Air Force Sustainment Center
Air Force Materiel Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Place of performance
- Warner Robins, Georgia 31098, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Air Force Sustainment Center at Robins Air Force Base seeks a Carrier-brand 15-ton air-cooled chiller unit for Building 207, with quotes due July 30 at 12:00 PM Eastern. This is a Total Small Business set-aside under Simplified Acquisition Procedures for commercial items.
Place of performance is Warner Robins, Georgia. The chiller must operate on 460 volts, 3-phase, 60 Hz power and include a 5-year warranty on parts, start-up service, brazed plate heat exchanger with evaporator heater, standard SCCR, coil face shipping protection, single point no disconnect, digital compressor, standard sound rating, microchannel heat exchanger, BACnet IP connectivity, Greenspeed Intelligence variable condenser fans, and PIC6 controls. Delivery is required within two to four weeks of award, FOB Destination to Building 1555, with the unit to be transferred to Building 207 by the contractor. The contractor is responsible for unloading at Building 1555 and delivering to Building 207; the Government or its installation contractor will complete all mechanical, electrical, piping, and controls connections. Contractor start-up is limited to equipment start-up and operational verification after Government installation is complete. All contractor personnel must possess valid state-issued driver's licenses, pass background checks for base entry, and comply with Robins AFB security requirements and OPSEC protocols. Work hours are Monday through Friday, 0800–1600 hours, with all federal holidays recognized. Quotes must include cost breakdown, unit price, total price, payment terms, prompt payment discount, DUNS number, and cage code. NAICS is 333415; PSC is 4130. Small business size standard is 1,250 employees. Government points of contact are Roy Bowden (primary, 478-327-8969) and Gregory Wilson (alternate, 478-327-5372). Questions and answers posted July 29 clarified delivery requirements and contractor responsibilities.
Notice text
2 versions
Update #2 · Latest ·
See updated PDF documentation as of 14Jul26
This is a Brand Name Carrier unit, not equal to with salient characteristics, must be a Carrier Brand meeting the requirements
Update #1 ·
See attachments
Files
| File | Type | Posted |
|---|---|---|
| B207 Chiller RFI pt2 29July26.pdf | ||
| B207 Chiller RFI.pdf | ||
| Requirement Description Chiller at Building 207.pdf | ||
| Combo Solicitation Chiller at Building 207.pdf | ||
| Requirement Description Chiller at Building 207.docx | DOCX document | |
| Combo Solicitation Chiller at Building 207.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| B207 Chiller Combo | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Chiller | Aviation | No set-aside | |
| 500-Ton Trailer-Mounted Air-Cooled Chiller | Kennedy Space Center | No set-aside | |
| Chiller | Land and Maritime | No set-aside | |
| Chiller assy, aircra | Aviation | No set-aside | |
| Troubleshoot & Repair of Portable Chillers Service Requirement | Air Education and Training Command | Total Small Business |