Atlantic undersea test and evaluation center (AUTEC) replace water storage tanks, alantic undersea test and evaluation center (AUTEC), andros island, bahamas.
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- N6945026R0006
- Agency
-
Naval Facilities Engineering Command
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 237110 Water and Sewer Line and Related Structures Construction
- Place of performance
- Andros Island Bahamas, THE
Notice details come from SAM.gov. Updated .
About this opportunity
The Naval Facilities Engineering Command is conducting a sources sought announcement to identify potential contractors for a Design Bid Build construction project to replace water storage tanks at the Atlantic Undersea Test and Evaluation Center (AUTEC) on Andros Island, Bahamas. The project involves replacing two existing 750,000-gallon finished water holding/contact tanks with new 500,000-gallon tanks, demolishing existing tanks and abandoned piping, and constructing a new 150,000-gallon elevated storage tank to repair and update the potable and fire supply water system. Qualified contractors must demonstrate experience with elevated water tank construction, concrete water storage tanks of 300,000+ gallons capacity, and potable water distribution piping installation. The government is particularly seeking to identify small business capabilities across various categories including SBA certified 8(a), HUBZone, woman-owned, veteran-owned, and service-disabled veteran-owned small businesses. Capability statements are due by October 16, 2025, at 12:00 PM Eastern Time and must be submitted via email with specific requirements including bond capacity documentation and SAM registration details.
This opportunity does not utilize any specific set-aside designation, as the government is conducting market research to determine the appropriate procurement approach based on responses received. No incumbent contractors are identified in the announcement materials. The total project magnitude is estimated between $10-25 million, with a firm-fixed price contract structure anticipated for award in June 2026. The scope includes replacing a total water storage capacity from 1.5 million gallons (two 750,000-gallon tanks) to 650,000 gallons (500,000-gallon and 150,000-gallon tanks), representing a strategic shift in the facility's water storage configuration. The government will use the sources sought responses along with other market research to determine whether to limit competition to specific small business categories or proceed with an unrestricted solicitation for this critical infrastructure project.
Notice text
THIS IS A SOURCES SOUGHT ANNOUNCEMENT, A MARKET SURVEY FOR WRITTEN INFORMATION ONLY TO IDENTIFY POTENTIAL OFFERORS FOR THE DESIGN BID BUILD CONSTRUCTION PROJECT, ATLANTIC UNDERSEA TEST AND EVALUATION CENTER (AUTEC) REPLACE WATER STORAGE TANKS, ALANTIC UNDERSEA TEST AND EVALUATION CENTER (AUTEC), ANDROS ISLAND, BAHAMAS.
THIS IS NOT A REQUEST FOR PROPOSALS OR AN INVITATION FOR BID. NO CONTRACT WILL BE AWARDED FROM THIS ANNOUNCEMENT. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS ANNOUNCEMENT OR ANY FOLLOW-UP INFORMATION REQUESTS. No telephone calls will be accepted requesting a bid package or solicitation. There is no bid package or solicitation currently available. In order to protect the procurement integrity of any future procurement that may arise from this announcement, information regarding the technical point of contact will not be given and no appointments for presentations will be made.
The purpose of this notice is to gain knowledge of qualified and interested parties in any of the following categories: small business, U.S. Small Business Administration (SBA) certified 8(a), SBA certified HUBZone, woman-owned small business (WOSB), veteran-owned small business (VOSB), and service-disabled veteran-owned small business (SDVOSB). Potential sources should have current relevant qualifications, experience, personnel, and capability to perform this proposed project. The type of solicitation to be issued will depend upon responses to this sources sought notice. The Government will use the sources sought responses along with other market research to make various determinations regarding the procurement
Project Description: This project repairs, by replacement, a portion of the potable and fire supply water system at AUTEC, returning the system to the original design intent while updating the system to account for current use characteristics.
The items to be updated include two (2) finished water holding/contact tanks, anelevated storage tank, and interconnecting piping. Two existing finished water tanks that have reached
the end of their useful life will be demolished, along with abandoned piping.
There are currently two tanks, each with a volume of 750,000 gallons, within the boundary fence of
the water treatment plant. These tanks supply the necessary capacity to fight fires and, together,
provide the contact time necessary to meet disinfection requirements. A 15% design study completed
by AH Environmental Consultants, Inc. in 2023 determined that the capacity of the tanks could be
reduced to 500,000 gallons each (total storage of 1,000,000 gallons).
An elevated storage tank, 150,000 gallons in volume, will be constructed at the location of the old
water tower that was removed after it was determined to have reached the end of its usable lifecycle
and was closed under a RAC 3 safety deficiency. Installation of the 150,000-gallon tank returns the
system to its original design.
Any resultant contract will be firm-fixed price. The North American Industry Classification System (NAICS) Code is 237110, Water and Sewer Line and Related Structures Construction, Product Service Code (PSC) is Z2NE, Repair or Alteration of Water Supply Facilities, with the annual size standard of $45.0 million. The project magnitude is between $10,000,000 and $25,000,000. Under the FAR guidelines, the prime contractor must have the capability to perform at least 20 percent of the contract work with its own employees. The anticipated award date is June 2026.
Industry will be notified of the results of this evaluation and set-aside determination via the pre-solicitation/ synopsis notice.
Interested sources are invited to respond to this sources sought announcement. See Attachment.
Files
| File | Type | Posted |
|---|---|---|
| AUTEC Replace Water Storage Tanks.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Atlantic undersea test and evaluation center (AUTEC) water tanks replacement, alantic undersea test and evaluation center (AUTEC), andros island, bahamas | Solicitation | |
| Atlantic undersea test and evaluation center (AUTEC) water tanks replacement, alantic undersea test and evaluation center (AUTEC), andros island, bahamas | Pre-Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Request for Information – Four FY24 Design-Build to Budget Projects; Fort Shafter, HMR, Schofield Barracks and Schofield Barracks East Range. | ENDIST Honolulu | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity