Ashland Warehouse
Closed Solicitation Posted
- Solicitation number
- 1620000203
- Agency
-
Federal Correctional Complex Forrest City
Correctional Facilities, Department of Justice
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 493110 General Warehousing and Storage
- Place of performance
- Ashland, Kentucky 41105, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Justice Bureau of Prisons is seeking proposals for the rental of an industrial use warehouse building within 30 miles of the Federal Correctional Institution in Ashland, Kentucky. The warehouse will be used to house case good furniture and raw materials for the UNICOR factory. Key requirements include a minimum of 33,000 to 37,000 square feet of space with at least 12-foot ceilings, three dock doors, a drive-through door for semi-trucks, 400-amp 3-phase electrical service, fire suppression, bathroom facilities, LED lighting, HVAC, and an 80 square foot office. Proposals are due by April 9, 2024 at 2:00 PM EST.
This solicitation is not set aside for any specific business type. The place of performance is Summit, Kentucky. The total contract value and any potential incumbents are not specified in the documents provided. The warehouse must be located within 30 miles of the Federal Correctional Institution in Ashland, Kentucky.
Notice text
Statement of Work
Industrial use building that can be used for housing case good furniture and raw material for the Ashland, KY UNICOR factory. The building must be within 30 miles of the Federal Correctional Institution located a 1 Federal Way, Ashland KY 41105.
The provider must include trash, electrical and gas (if required) service. The space must be secured and weatherproof to meet the minimum requirements below.
Minimum Requirements
- A minimum of 33K – 37K Sq. ft. if at least a 12’ clear high ceiling. This includes both inside and outside square footage with inside square footage estimated at 25K and 8k to 12k of outside square footage.
- Square footage to be increased the lower the ceiling is due to the loss of vertical space.
- A desired minimum of three dock doors with weather protection and floating dock plates
- It is preferred if the space has a drive door for a semi (12’ wide x 16’ high would be preferred) so that a semi can drive all the way through if needed.
- Minimum of a 400amp 3 phase service for the potential need for charging electric forklifts and potential light warehouse tools
- Fire Suppression would be required to meet state standards
- Bathroom as minimum required to meet state standards
- Lighting to be LED high bay an provide at warehouse level lighting throughout the space
- Minimum heating / cooling to protect fire suppression and bathroom water systems.
- Minimum of 1 room ( at least 80 square feet) usable as an office with appropriate lighting and drop ceiling
- Minimum of 1 designated storage location for propane cylinders
- Blacktop parking for minimum required vehicles to meet the state standards