ARC Flash Maintenance

Cancelled Solicitation Posted

Solicitation number
36C10X24Q0230
Agency
Responses due
Set-aside
Veteran-Owned Small Business

Opportunity facts

NAICS code
561210 Facilities Support Services
Place of performance
Martinsburg, West Virginia 25404, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Strategic Acquisition Center - Frederick is seeking to procure ARC Flash Maintenance services through a firm fixed price contract. The contractor must provide a comprehensive review of the existing arc flash analysis report to confirm there have been no significant changes to the electrical system that have impacted incident energy, arc flash protection boundaries, or required personal protective equipment (PPE). Calculations must comply with NFPA 70E and IEEE-1584. If new arc flash labels are required, the contractor will provide and install updated labels as necessary. Quotes are due by June 13, 2024 at 12pm EDT.

This procurement is set aside for 100% Veteran-Owned Small Businesses. The place of performance is Martinsburg, WV, USA. The solicitation number is 36C10X24Q0230. No incumbent or current contractor information is provided. The government has not specified an award value or budget range for this requirement.

Notice text

2 versions

Update #2 · Latest ·

This requirement has been cancelled due the questions recieved and need to re-examine the aquisition stragey. 

In accordance with NFPA 70E, a review of the existing AF analysis must be performed every 5 years if no significant changes to the electrical systems have occurred on all electrical equipment that may require energized operation or inspection.  The contractor must provide a comprehensive review of the existing AF analysis report to confirm that there have been no significant changes to the electrical system that have impacted incident energy, arc flash protection boundaries or required PPE for electrical equipment.  Calculations must comply with NFPA 70E and IEEE-1584.  If new arc flash labels are required, the contractor will  provided and install updated labels as required for all equipment that is compliant with NFPA 70E,  National Electric Code (Article 110.16), OSHA 1910.303, and 1910.335 (b)(1).  The contractor must provide all labor, materials and testing/analysis required to complete the work described in this PWS. This is a firm fixed price contract.

Update #1 ·

In accordance with NFPA 70E, a review of the existing AF analysis must be performed every 5 years if no significant changes to the electrical systems have occurred on all electrical equipment that may require energized operation or inspection.  The contractor must provide a comprehensive review of the existing AF analysis report to confirm that there have been no significant changes to the electrical system that have impacted incident energy, arc flash protection boundaries or required PPE for electrical equipment.  Calculations must comply with NFPA 70E and IEEE-1584.  If new arc flash labels are required, the contractor will  provided and install updated labels as required for all equipment that is compliant with NFPA 70E,  National Electric Code (Article 110.16), OSHA 1910.303, and 1910.335 (b)(1).  The contractor must provide all labor, materials and testing/analysis required to complete the work described in this PWS. This is a firm fixed price contract.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Arc Flash Hazard Analysis Services Clarksburg, West Virginia 26301, United States · NAICS 334515 Veterans Integrated Service Network 5 No set-aside
H361--LEX Triannual Energy Study and ARC Flash Testing Department of Veterans Affairs Lexington, KY Bowling & Sousley Divisions, Lexington, Kentucky 40511, United States · NAICS 238210 Veterans Integrated Service Network 9 Service-Disabled Veteran-Owned Small Business
H259--Essential Electrical System (EES) Switch Gear Testing Department of Veteran Affairs San Diego VA Medical Center San Diego CA 92161 · NAICS 811310 Veterans Integrated Service Network 22 Service-Disabled Veteran-Owned Small Business
WCF Electrical Substation Upgrade Fort Worth, Texas 76131, United States · NAICS 238210 Bureau of Engraving and Printing Service-Disabled Veteran-Owned Small Business
CTX VAMC Maintenance, Calibration, Inspection, and Testing of the Electrical Power Distribution System Temple, Texas, United States · NAICS 811310 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors